HomeMy WebLinkAboutRIGDEN FARM, NORTHWEST ROADS - FDP - 56-98AE - CORRESPONDENCE -Department: Water Wastewater Issue Contact: Jeff Hill
Topic: 6eneroi
Number: 7 Created: 12/10/2004
[6/15/05] Please remove the ARV from Limon Dr and add the previously
indicated ARV on Iowa Dr. Clearly define the ARV in all appropriate views.
[2/28/05]
[12/10/04] It appears that an air relief valve may be needed at approximately
14+00 of the sanitary sewer profile on Iowa drive. Provide ARV's at all water
main high points.
Number: 51 Created: 6/15/2005
(6/15/051 Provide utility easements on the tract of land north of Limon and
West of Kansas for all utilities which are being stubbed into the site.
Number: 52 Created: 6/15/2005
[6/15/05] Include the typical water service detail on the next submittal.
See the utility plans for other comments
Please be sure and return all red -lined plans if/when you re -submit.
If you have any questions regarding these issues or any other issues related to
this project, please feel free to call me at 221-6341.
Yours Truly,
ZOMW
Steve Olt
City Planner
Cc: Sheri Wamhoff
Current Planning File #56-98AE
Page 4
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Eroding
Number: 53 Created: 6/15/2005
[6/15/05] Please move the spillway on Pond 212 at least 6 feet from the back
of the right of way.
Topic: Plot
Number: 54 Created: 6/15/2005
[6/15/05] Please add drainage easements to the platted tracts being where
storm lines are stubbed.
Topic: Utility Plans
Number: 12 Created: 12/14/2004
[6/14/05] The provided detail for the wing wall is a general detail with no
actual dimensions or angles. Please provide a construction level detail for the
proposed wing walls.
[2/25/05] Please provide a detail for the proposed pan as well as for the
proposed wing walls at the bottom of Pond 212. All other issues have been
addressed, thank you.
Please remove all references to Rigden Farms loth Filing from plans and report,
as these plans should be labeled Rigden Farms - Northwest Roads.
[12/14/04]
Please add pipe inverts to the grading plans.
Please call out the slope at the bottom of pond 212, a pan may be needed there
due to the apparent minimal slope.
Plans call for the pond outlet to tie in to an existing 24" CMP, the existing pipe
in Kansas Drive is a 30" RCP.
Please provide a detail for the proposed concrete wing walls in detention pond
212.
Please make sure all storm sewers have the minimum 2 foot cover required.
Please provide a detail for the proposed pond outlet, as well as a spillway
location and detail.
Page 3
Number: 30
Created:12/17/2004
[6/21/05] Please see plans for additional comments.
[2/25/05] Please see plans for additional comments.
[12/17/04] Please see plans for additional comments.
Number: 37 Created: 2/25/2005
[6/21/05] not yet addressed.
[2/25/05] The emergency overflow spillway - Need to provide a plan view detail
and/ or dimension that locates this spillway behind the row. This spillway can
not be placed directly behind the row. It needs to be placed it appears 6 feet
minimum back from the row to accommodate the future sidewalk and the
grading that is needed for the berm.
Topic: street design
Number: 41 Created: 2/25/2005
[6/21/05] add the note I wrote in on the cover sheet and I think this will be
covered.
[2/25/05] What signage and striping are you proposing? Any?
Number: 55
Created: 6/21/2005
(6/21/05] Received the legal descriptions for some of the easements needed.
I will have them checked. Will need the deeds of dedications for these
easements and deeds and legals for the ones not yet provided.
Number: 56
[6/21/05] Determined no DA needed.
Department: Light $ Power
Topic: 6enernl
Created: 6/21/2005
Issue Contact: Monica Moore
Number: 2 Created: 12/3/2004
[5/24/05]
[12/3/04] Normal electric development charges and policies will apply. At time
of development, front footage along dedicated roads and street lighting will be
charged. Additional development charges will occur as tracts develop.
Number: 50 Created: 5/24/2005
[5/24/05] No further comments.
Page 2
STAFF PROJECT REVIEW
Citpof Fort Collins
J*R Engineering Date: 06/22/2005
c/o Michael Brake
2620 East Prospect Road, Suite 190
Fort Collins, CO. 80525
Staff has reviewed your submittal for RISDEN FARM, NORTHWEST ROADS
- PDP, #56-98AE, and we offer the following comments:
ISSUES:
Department: Engineering
Topic: 6eneml
Issue Contact: Sheri Wamhoff
Number: 23 Created: 12/17/2004
[6/21/05] missing a couple yet.
(2/25/05] still applicable.
[12/17/04] Indicate all easements to be dedicated by separate document -
show these on the plat. As we discussed we can not vacate the wide stormwater
easement until after the swale has been piped. Once that is done the easement
can be vacated by separate document or when the property is plated for
development.
Number: 28
Created. 12/17/2004
[6/21/05] No soils report has yet been submitted to my knowledge.
[2/25/05] No soils report has yet been submitted.
[12/17/04] No soils report was submitted - need to submit a soils report.
Number: 29 Created: 12/17/2004
[6/21/05]
[2/25/05] Still true - no response needed - being carried forward as a
reminder to the developer
[12/17/04] No utility services or driveways are shown on these plans to the
adjacent parcels. At the time that the adjacent parcels develop and services
are provided. The developer will be charged the triple street cut fees and/or
will be required to overlay the street to repair the area impacted by the utility
and driveway installations. This will be determined at the time of construction
based on the impact to the street.