HomeMy WebLinkAboutRIGDEN FARM, 11TH FILING, BROOKLYN PARK ROW HOUSES - PDP - 56-98AD - CORRESPONDENCE - (5)Light & Power 1. The proposed 2 electric vaults is not enough for this many dwelling units. Engineering :, 1. The driveways between the buildings will ice over. Concrete would be a better pavement material than asphalt in these locations. 2. The driveway entries can have no more than a,4% grade. The plans are showing an 11% grade.- :;. �•..._....•�..._.... �..._._. :.__..:_.._ _.. .: 3. A utility coordination meeting is needed. This completes staff (and outside reviewing agencies) review and comments at this time. Red -lined plan from City departments are included with this comment letter. Additional comments and red-lined:plans,muy.be forthcoming: Another round of staff review is necessary. This. proposal, is subject to the 90-day revision re -submittal requirement (from the date of this comment letter, being May 11, 2005) as set forth in Section 2.2.11(A) of the Land Use Code. Be sure and return all red -lined plans when you re -submit. The number of copies of each document to re -submit is shown on the attached Revisions Routing Sheet. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, Steve Olt City Planner cc: Marc Virata Hearne Properties, LLC Interwest Consulting Group Current Planning File #56-98AD Page 11 Comcast Cable TV 1. bon Kapperman indicated that Tract A needs to be a utility & drainage easement on the outer edge of the whole project. This is due to the South Tract A being only a drainageeosement,.: Please: call: C6.mcast .0,at:484!".7A.66,, if you need more details. Xcel Enerav 1. Len Hilderbrand offered the following comments: a. Need to mark gas meter locations on all units to make sure that the clearance requirements from other utilities and any openings are being met. b. Need utility easement to extend all the way along the west end of the project, along Iowa Drive. It appears not to continue across the emergency & access easement. c. Services must be installed prior to patios being installed. Cily Forester 1. Change street tree species as noted on the marked -up Landscape Plan that is beingf . i I forwarded to the applitiint.) Water/Wastewater 1. The water and sanitary as -proposed are not: Working. A utility coordination meetin# is needed. Stormwater ...... 1. There is a conflict between the storm sewer and the trees along the east side of the property. Trees must be 10' from the sewer. A maintenance agreement is needed. V Page 10 n 4 Number. 3 Created-. 4/15/2005 [4/15/05] Remove topography lines from the ffinal site plan. Number: 4 :-* ^, '' :', " ' , -, . Created: 4/15/2005 ' " ' [4/15/05] Regarding parking spaces in the center of each building: I'm not so sure the planters on either side will last very long, granted the space is 10' wide, but I foresee people driving into them trying to turn in to the parking spaces. Just something to re-ev.-1d10dft"_ Number: 5 Created: 4/15/2005 [4/15/05] NOTE - one of the handicap spaces will need to be signed as "Van Accessible". Number- 6 Created. 4/15/2005 [4/15/051 Note the building height -on theelevations Number: 7 Created: 4/15/2005 [4/15/05] No rear or side elevations were provided. Number: 8 _COdatecl: 4/15/2005 [4/15/05] What are the proposed: colors/materials for -the, restof the units ... only the end units are noted. Number: 9 Created: 4/15/2005 [4/15/05] On the landscape plan, please note the item count next to the item symbol. Example: PF-3, or something- iirihildr ' . . I Number: 10 Created: 4/15/2005 [4/15/05] Add a note to the landscape plan regarding installation of landscaping prior to issuance of a CO. See section 3.2.1(1)(4) Additional Comments from City staff and outside reviewing agencies: Building Department 1. Rick Lee is forwarding a copy of the various codes that his department will enforce. Page 9 n Department: Water Wastewater Issue Contact: Jeff Hill Topic: 6enerol Number: 32 Created: 4/28/2005 [4/28/05] A utility coordination meeting: is needed to'discuss the proposed utility layout. Number:33 , - Created:,4/2.8/2005 [4/28/05] Maintain a 10 foot separation between water.services/underground utilities and thrust blocks. Number: 34 Created: 4/28/2005 [4/28/05] The City of Fort Col lins-.utilities:-only,allows _1-inch.and 1.57inch water service. Please correct the utility!plans.toartflect:this, .: Number: 35 Created::/.28/2005...,:::, . [4/28/05] No water services are per.mitted,beyond-the- last; fire hydrant: . Number: 36 ...... ;::.-r. : rCreated::4/28/2005 [4/28/05] Fire hydrant laterals may not extend through potential landscape areas. Provide a 20 foot utility easement for the proposed fire hydrant lateral with the lateral centered in theiutility(easement. Aointain:l0:feet•of,. separation between the fire hydrant- lateral and:.the proposed sanitary sewer manhole. cu, ,..,! Number: 37 Created: 4/28/2005 [4/28/05] See site, landscape and utility plans for other comments. Department: Zoning Issue :Contact:. Jenny Nuckols Topic: Zoning Number: 1 Created: 4/15/2005 [4/15/05] Show and label building'envelope; footprint, dimensions and distance to property lines :nnC n.; ::uI-rl Number: 2 Created: 4/15/2005 [4/15/05] Remove landscaping from site plan, please just show on the landscape plan. Page 8 i Topic: Storm Line Maintenance Number: 20 Created: 4/26/2005 [4/26/05] We need to discuss how maintenance would occur for the storm sewer on the south end of the property and the one on the east end of the property. A maintenance agreement between City and Developer will be needed. Maintenance and access to the east sewer line will be difficult, as the south line can be accessed from the church parking lot. Will need to coordinate with the Colony development in Rigden Fcr."ms access to the east'line. Topic: Utility Plans Number: 39 Created: 4/28/2005 [4/28/05] Pipe profiles are not:required-until final submittal, however, you may want to check and make sure that the proposed grades will provide a minimum one foot cover for the pipe along the south property line. Also check and see whether the depth of the pipe willall'ow the pipe to be dug up'for maintenance purposes at a 1:1 slope from theedge of 4he pipe to.the,proposed stairways. Department: Transportation Planning Issue Contact: David Averill Topic: Construction Plans Number: 29 Created:4/27/2005 [4/27/05] I'm a little concerned with grades of the driveway crossing of the street sidewalks. Seems like it may,be:probiematic:for:�drivers to assess what is coming down the sidewalk. Atistaff'review ifi sounded, like there maybe some site plan changes, so perhaps this will be addressed out of some other necessary change. Number: 30 Created: 4/27/2005 [4/27/05] A question: how much thought has been given to how this development will relate (specifically through pedestrian connections) to the other development (existing and proposed) on the surrounding parcels. I understand that there is only so- 'much that this applicant can do to facilitate coordination with other developments, but I urge the applicant to explore the options as much as is practicable,., Iam of course, available to help in any discussion that takes place. Thanks. Page 7 Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Department: Police Issue Contact: Joseph Gerdom Topic: Eeneral Number: 19 -Created: 4/26/2005 [4/26/05] Lighting: the LUC calls for a minimum of 1.0fc in parking and drives; 0.5fc along pathways; and min of 0.3 for pedestrian stairways - several areas fall below this. - Department: Stormwater Utility Issue Contact= Basil Hamdan Topic: Eroding Number. 38 Created: 4/28/2005 [4/28/05] The grades around the south end. of the siteand how they .tie into the neighboring property are not clear, please make sure that no drainage from the site will discharge on the church property,_a.couple.of.cross sections for that area may be beneficial as well.;--.,...! _. Topic: Landscape Plan Number: 18 Created: 4/26/2005 [4/26/05] If any trees are required_byplanning-,on thesouth side of .Building 4, then please maintain 10 feet of clearance from centerline of pipe. It appears that there are trees proposed within 2-3 feet of the existing storm line along the eastern property Iine:;,ThisAistance.wiII make. it. impossible for . the City to maintain that storm line. r Topic: Plot Number: 17 Created: 4/26/2005 [4/26/05] Please designate Tratt: A. as a. drainage easement as well. Topic: Stairway in Drainage Easement Number: 40 Created: 4/28/2005 [4/28/05] As currently drawn the drainage easement on the south property line, encompasses a permanent structure, the stairway which is not allowed. You need to either move the easement line around the stairways or move the stairways outside of the easement as currently shown. Page 6 Department: PFA Issue Contact: Michael Chavez Topic: General Number: 14 Created: 4/22/2005 [4/22/05] REQUIRED ACCESS: A fire lane is required. The fire lane shall be visible by painting and signage, and maintained unobstructed. 1997 UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1; FCLUC The criteria for a required fire lane contain several conditions that must be met. I. 1. The minimum width shall be 20 feet. 2. Inside turning radius shall be 25"feet and 'outside turning radius shall be 50 feet. 11 3. Compacted road base shall be used during the construction phase only. The permanent fire lane shall consist. af'-asphaltvr.-.concr..ete:and shall.be:required to support 40 tons 4. The fire lane shall be platted•as:an-"Emergency,Access Easement! on the final plat. Buildings three stories or more in height-musf have access to,a30-foot::, unobstructed access roadway owafileasf:-(1)"oneside-fomaeria[operations. PFA . . Policy 85-5 (8) Number:15 c •ii Created:4/22/2005 [4/22/05] PREMISES IDENTIFICATIONrApproved -numerals or-nddresses shall be provided for all new and existing building in such a position as to be plainly visible and legible from the street or road fronting the property. 1997 UFC 901.4.4 A. In Multi -story buildings the followingrequirem'entiSshall'pertain: 1. The first floor units shall be designated,with i00's. 2. The second floor units with 200's 3. The third floor units with 309s, and so forth. B. All brass letters and numerals shall be posted on a black background. C. Some multi -family layouts may rei'qhjire address postings from the back side as well as the front of the buildings. D. A clockwise addressing pattern shall be maintained when ever possible. Number: 16 Created: 4/22/2005 [4/22/05] WATER SUPPLY: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Page 5 Number: 42 Created: 4/29/2005 [4/29/05] The plans need to ensure that any above ground structures are separated 2' from any public sidewalk. Topic: 6enerol Number: 23 Created: 4/27/2005 [4/27/051 Given comments thus far, a utility coordination meeting may be beneficial. Department: Light $ Power Issue Contact: Monica Moore Topic: General Number: it Created: 4/19/2005 [4/19/05] Conceptual Review Response Letter states -that transformer locations have been coordinated with Light and Power. This issue has not been resolved. Transformer locations -still need to be coordinated and a combined utility coordination meeting still needs to, occur::,,Utility-plan shows-2 vaults with transformers in R-O-W. Current.layout_would require.each building to have it's own vault with transformer. Notes on the utility plan call for pad mount transformers to be installed. Pad transformers cannot be installed in the RO- W. These would be installed in a utility easement on the property itself. In addition, these notes state that: the secondary. lines will be installed by the developer from the transformer to the meters. These lines will be installed and maintained by Light and Power.:. Number: 12 Created: 4/19/2005 [4/19/051 Utility plan needs to show planned and existing facilities. Water & Sewer lines must maintain 10-feet of clearance to electric lines. Gas lines must maintain 5-feet of clearance. Number: 13 Created: 4/19/2005 [4/19/05] Utility plan calls for electric meters to be located on the front wall of each building. Show profile for the location of these meters with relation to windows, doors, other meters, etc. Page 4 Number: 25 Created: 4/27/2005 [4/27/05] The silt fence and storm pipe information on Sheet 6 obscures the on -site contour line information. Please revise to make this area clearer. Number: 26 Created: 4/27/2005 [4/27/05] The longitudinal grades for the driveway entrances past the sidewalk along Iowa Drive are in the 11% range which exceeds the criteria specified in LCUASS Figure 8-17 which requires no more than 4% grade for a distance of 65' from the flowline of Iowa Drive. Number: 27 Created: 4/27/2005 [4/27/05] As a suggestion (not a requirement), the use of inverted crown asphalt drives, (especially in areas such as these with tall structures surrounding) may be problematic with regards to winter months and potential freeze -thaw -freeze issues. With some slopes in the 1.3% range, water may not drain sufficiently along these grade with asphalt such that icing conditions may occur. It may be worth looking into using concrete for these potential safety and maintenance issues. Number: 28 1 Created: 4/27/2005 [4/27/05] The variance request regarding the driveway separation is acceptable. The variance regarding depth to the first parking stall is likely acceptable, though I would like to verify the resolution of ID 26 before committing to the approval of this variance request as there seems to be some interrelation between the two. Number: 31 Created: 4/27/2005 [4/27/05] It needs to be verified at this time how roof drainage will be directed. It needs to be demonstrated that such drainage won't be directed over a public sidewalk (Custer or Iowa). Number: 41 Created: 4/29/2005 [4/29/05] The plans need to ensure that no above ground pedestals are located in between any public sidewalk and curb and gutter of the associated public street. Page 3 Topic: Site Plan Number: 44 Created: 5/11/2005 [5/11/05] There must be a minimum 5' setback of the driveway and parking from the lot line along the east side of the development. Only 4' is presently shown. Number: 45 Created: 5/11/2005 [5/11/05] To satisfy Section 3.5.2(C)(2) of the LUC the units at the west ends of Buildings 2, 3, and 4 must have doorways facing Iowa Drive. Number: 46 1. 1 Created: 5/11/2005 [5/11/05] The primary entrances to the 3 easterly units in Building 4 are further than 200' from a street sidewalk and, therefore, require a connecting walkway in the form of a "major walkway spine" back to the sidewalk along Iowa Drive. As shown on the Site Plan the walkway does not meet the definition of a major walkway spine. The area between the building and the property line is too narrow and the Landscape Plan does not satisfy the landscaping requirements. Number:47 - Created: 5/11/2005 [5/11/05] A sidewalk connection to -the -Colony project to the east should be provided. Department: Engineering Issue Contact: Marc Virata Topic: Construction Plans Number: 21 Created: 4/27/2005 [4/27/05] On Sheet 4, show the patching notes along Iowa Drive to be half a parking lane width not 1' and reference Note #7. Number: 22 Created: 4/27/2005 [4/27/05] Given the notes 4-6 on Sheet 5 it would appear to be appropriate to have City Light and Power added to the City's approval block and have individual approval blocks for both Xcel and Qwest. Number: 24 Created: 4/27/2005 [4/27/05] Please label the contour lines outside of the property boundaries to better verify that grades are being tied into properly on -site. Page 2 J STAFF PROJECT REVIEW City of Fort Collins M. Torgerson Architects Date: 05/11/2005 c/o Troy Jones 223 North College Avenue Fort Collins, CO 80524 Staff has reviewed your submittal for RIGDEN FARM, 13TH FILING, BROOKLYN PARK ROW HOUSES - PDP, and we offer the following comments: ISSUES: Department: Current Planning Topic: Building Elevations Issue Contact: Steve Olt Number: 50 Created: 5/11/2005 [5/11/05] The building height should be shown on the Building Elevations. Number: 51 Created: 5/11/2005 [5/11/05] Rear and side building elevations are needed. The cover sheet indicates that there is a Building Elevation sheet 4 of 6; however, it appears that this sheet was not submitted. Topic: General Number: 43 Created: 5/11/2005 [5/11/05] The filing # for this PDP should be changed to 11th Filing instead of 13th Filing. This is because of a change on the Spectrum Independent Living PDP. Topic: Landscape Plan Number: 48 Created: 5/11/2005 [5/11/05] A minimum 5' wide landscaped area is required along the eastside of the development between the driveway/parking and the property line. See Section 3.2.1(J) of the LUC. Number: 49 Created: 5/11/2005 [5/11/05] The landscaping as shown along the east property line is insufficient to screen the "vehicular use area'. See Section 3.2.1(E)(4) of the LUC. Page 1