Loading...
HomeMy WebLinkAboutRIGDEN FARM, 8TH FILING, LOT 5, GREASE MONKEY/CARWASH - PDP - 56-98AI - CORRESPONDENCE - REVISIONS (3)inSITE' ineering February 9, 2006 Staff Project Review Team City of Fort Collins Fort Collins, CO 80522-0580 3337 East 138th Avenue Thornton, Colorado 80602 RE: Grease Monkey and Carwash, , Lot 5, Rigden Farm, r Filing Response Letter To Whom It May Concern: Insite Engineering has made its best attempt to address staff comments for their review dated January 3e, 2006. Please find responses to specific comments below that may require clarification: Comments regarding existing and proposed contours on the plans. The survey was performed during construction of The Shops at Rigden Farms and our lot was not in a final condition at that time. At the time of the survey this site was being used for the construction trailer offices. We have coordinated our plans and grading with the master plan from Kimley Horn and also the gas station located East of us. Checking against elevations shown on the two existing plan sets and our proposed grades we feel our site will tie seamlessly with what is existing now. Conversations and voice mails have been exchanged with Sheri Wamhoff of Engineering. Based upon direction from Miss Wamhoff we have added note 8 to Sheet 3, Grading & Drainage. In addition, notes 5, 6, 7 on this sheet serve as notice to the contractor that care should be taken during layout and construction of the site due to the basis of design. • Comments requiring Drainage and Erosion Control Report. Direction was given by Basil Hamdan in a meeting on May, 18°t 2005 that only a general letter of compliance would be required due to the size of our site and its incorporation into the existing master drainage report for the Shops at Rigden Farms. Erosion Control information is provided on Sheet 5, Erosion Control, on the proposed plans. A letter of compliance has been submitted several times on approximately 6/28/05, 1/4/06, and additional comments have been addressed and are being submitted on 2/09/06. • Comments regarding spill containment measures. The proposed Grease Monkey and Carwash are self contained businesses with material handling taking place internally. The risk of spills that may contaminate the stormwater system is extremely minimal. A Kristar Inlet Fitter has been proposed on the inlet that will receive flows from the majority of the site that may be felt to be at risk This fitter is noted for installation on Sheet 4, Utility, and a detail is provided for review on Sheet 7, Details 2. Sincerely, Kurt Kowar, P.E. Principal Insite Engineering phone: 720.339.3759 • fax: 720.528.7867 • email: kkowar@insiteeng.com • www.insiteeng.com