HomeMy WebLinkAboutRIGDEN FARM 5TH FILING, LOT 1 REPLAT, RIGDEN LOFTS AT SETTLER'S GREEN - PDP - 56-98AT - CORRESPONDENCE - (5)This completes staff (and outside reviewing agencies) review and comments
at this time. Red -lined plan from City departments are included with this
comment letter. Additional comments and red -lined plans may be
forthcoming. Another round of staff review really is necessary, primarily
because of the requested reduced rear yard setback. This proposal is
subject to the 90-day revision re -submittal requirement (from the date
of this comment letter, being July 2, 2007) as set forth in Section
2.2.11(A) of the Land Use Code. Be sure and return all red -lined plans
when you re -submit. The number of copies of each document to re -submit
is shown on the attached REVISION ROUTING SHEET.
If you have any questions regarding these issues or any other issues related
to this project, please feel free to call me at 221-6341.
Yours Truly,
�� V
Steve Olt
City Planner
cc: Marc Virata
JR Engineering
Planning & Zoning file #56-98AT
Page 6
Number: 21 Created: 6/27/2007
[6/27/071 Change the sewer service clean -outs to the traffic rated type and
substitute to correct detail.
Number: 22 Created: 6/27/2007
[6/27/071 Revise the configuration of the water service coming off Custer as
noted on the red -lined plans.
Number: 23 Created: 6/27/2007
[6/27/071 Provide copy of the HOA documents which makes the HOA
responsible for the common sewer service.
Number: 24 Created: 6/27/2007
[6/27/07] Provide blow-up details of service lines where split occurs
showing reducers and sizes. Curb stops and service lines downstream must
be 3/4-inch.
Number: 26 Created: 6/28/2007
[6/28/071 There is an electric vault along Rigden Parkway that is not
shown on the plans and is in conflict with the new water service. Move
water service to provide a MINIMUM of 5 foot clear separation from the vault
(and street light pole??).
Department: Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number: 1 Created: 6/ 19/2007
[6/ 19/07] The plans show a 6' setback (typical). The LMN zone requires an
8' rear setback from an alley. Front setbacks in the LMN are 15', sides are
5' and corner sides are 15'. Please review your layouts.
Number: 2 Created: 6/ 19/2007
[6/ 19/07] There is a maximum density of 8 dwelling units allowed in the
LMN which works out to be a minimum of 5445 square foot per lot per
dwelling unit. These lots are about half that size - how does that affect the
overall density of the project?
Number: 3 Created: 6/ 19/2007
[6/ 19/07] With these units be alley accessed, one won't be able to park a
car in the driveway without with hanging into the alley. Verify with
Engineering if this is acceptable.
Number: 4 Created: 6/20/2007
[6/20/071 Elevations aren't necessary for single family lots. If you chose to
have the elevations as part of the recorded documents any changes that
might be made would require a minor amendment. Are all of the units
going to look exactly the same?
Page 5
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 17 Created: 6/27/2007
[6/27/071 WATER SUPPLY: Fire hydrant locations must be shown on the
plans. Fire hydrants, where required, must be the type approved by the
water district having jurisdiction and the Fire Department. Hydrant spacing
and water flow must meet minimum requirements based on type of
occupancy. Minimum flow and spacing requirements for residential
structures within Urban Growth Area are 1,000 gpm at 20 psi residual
pressure, spaced not further than 400 feet to the building, on 800-foot
centers thereafter. These requirements may be modified if buildings are
equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2
Number: 18 Created: 6/27/2007
[6/27/071 ADDRESS NUMERALS: Address numerals shall be visible from
the street fronting the property, and posted with a minimum of six-inch (6)
numerals on a contrasting background. (Bronze numerals on brown brick
are not acceptable). 97UFC 901.4.4
Department: Stormwater-Water-Wastewater Issue
Contact: Wes Lamarque
Topic: Erosion/Sediment Control
Number: 28 Created: 6/29/2007
[6/29/07] Please provide inlet protection for the nearest downstream inlet
from the site.
Department: Stormwater-Water-Wastewater Issue
Contact: Roger Buffington
Topic: Plat
Number: 25 Created: 6/27/2007
[6/27/071 Provide copy of plat for review.
Department: Stormwater-Water-Wastewater Issue
Contact: Wes Lamarque
Topic: Stormwater
Number: 27 Created: 6/29/2007
[6/29/071 No comments relating to storm water.
Department: Stormwater-Water-Wastewater Issue
Contact: Roger Buffington
Topic: Water/Wastewater
Number: 19 Created: 6/27/2007
[6/27/071 Reduce the size of the new water service to 1.5-inch.
Number: 20 Created: 6/27/2007
[6/27/071 Add clean -outs on the sewer service as shown on the utility plan.
Page 4
Topic: General
Number: 5 Created: 6/26/2007
[6/26/07] The proposed layout does not appear to comply with LCUASS
"Garage Door Set Back" requirements specified in 7-11 F as well as rear
setback requirements in the Land Use Code. After discussion among City
Staff including a site visit to the original Settler's Green project where a 6'
setback modification was granted, we're not in support of granting any
further variances/modifications to the 8' setback requirements in both
LCUASS and the Land Use Code. It's become apparent that in reducing the
setback to 6', residents and visitors are not discouraged from parking
parallel in front of the driveway and extending their vehicles onto the alley.
Number: 15 Created: 6/26/2007
[6/26/071 I don't believe the driveway approaches intersecting the alley
meet 9.4.2 of LCUASS regarding entrance angles. While a variance request
is required, City staff has agreed in concept to supporting such a variance
(the justification provided should be thoroughly stated).
Number: 31 Created: 6/29/2007
[6/29/071 In addition to the garage door setback requirements specified in
7-1 IF noted in #5, please note the fence setback requirement should fences
be proposed.
Topic: Plat
Number: 6 Created: 6/26/2007
[6/26/071 Please add the following note to the plat (if the applicant does not
elect to add the note, then a development agreement for the project will be
required):
"The Development Agreement for Settler's Green P.D.P. dated 9/5/2001,
between the City, Settler's Green Registered LLLP and Rigden Farm LLC
shall apply to the property shown on this replat."
Number: 30 Created: 6/29/2007
16/29/071 Technical Services offers the following comments:
1. Boundary closes.
2. Curve in the "tie" to boundary does not match Rigden Farm Filing 5.
3. Show adjoining streets and how dedicated.
4. What are the additional dashed lines? (setback should not be shown on
the plat)
5. 6' utility easement not locatable. Can eliminate lines -- see redlines.
Page 3
Number: 13 Created: 6/26/2007
16/26/071 Sidewalk widths for all walks shown on the Site Plan must be
provided.
Number: 14 Created: 6/26/2007
[6/26/071 The NEW PROJECT ROUTING SHEET indicates that the
required Site and Landscape Plans are combined on one sheet; however,
nothing on the plan really says what the existing or proposed landscaping
is. There are 5 "apparent" trees in the parkways, with no labeling, and Notes
#2 states that "All landscaping in front of this project is in and maintained
by the Rigden Farm HOX. Please label the existing street trees as such and
note that all landscaping on the individual lots will be by the individual lot
owners. Is there an overall Rigden Farm HOA that is maintaining these
street trees or are there multiple HOA's in this development? If so, which
one is this development part of?
Number: 32 Created: 7/2/2007
[7/2/07) The width of the public alley, both the right-of-way and the paved
surface, must be shown on the Site Plan.
Number: 33 Created: 7/2/2007
[7/2/07) The requested 6' rear yard setback is less than the required 8'
setback, requiring a request for a modification of the standard set forth in
Section 3.5.2(D)(3) of the Land Use Code. A request for a modification of this
standard was granted with the original Settler's Green @ Rigden Farm in
2001; however, this is a new PDP submittal and the requested substandard
setback must again be evaluated. There is some doubt as to whether or not
City staff will support a 6' setback because of now existing conditions and
circumstances along the alley.
Department: Engineering Issue Contact: Marc Virata
Topic: Construction Plans
Number: 7 Created: 6/26/2007
[6/26/071 Add the following note to the plan set: Damaged curb, gutter
and sidewalk existing prior to construction, as well as streets, sidewalks,
curbs and gutters, destroyed, damaged or removed due to construction of
this project, shall be replaced or restored in like kind at the Developer's
expense prior to the acceptance of completed improvements and/or prior to
the issuance of the first Certificate of Occupancy. The limits of the repairs
will be identified in the field by the City Engineering Inspector prior to and
over the course of the project and will not be shown on the plans.
Number: 29 Created: 6/29/2007
[6/29/071 Please expand the patching limits shown on the construction
drawing to the median of the roundabout sputter.
Page 2
STAFF PROJECT REVIEW
ON of Fort Collins
Dana McBride Date: 07/02/2007
Dana McBride Homes, Inc.
1510 Hillside Drive
Fort Collins, CO 80524
Staff has reviewed your submittal for RIGDEN FARM, 5th FILING, LOT 1
REPLAT, RIGDEN LOFTS AT SETTLER'S GREEN - PDP (TYPE 1), and we
offer the following comments:
ISSUES:
Department: Current Planning
Topic: General
Number: 16
[6/26/071 No comments.
Issue Contact: Dana Leavitt
Created: 6/26/2007
Department: Current Planning Issue Contact: Steve Olt
Topic: Site Plan
Number: 8 Created: 6/26/2007
16/26/07] On the Site Plan, what is meant by "9' Building Setback (Typ.)",
as shown on Lots 1 & 3? Is that 9' line really just the utility easement?
Number: 9 Created: 6/26/2007
[6/26/07] Please dimension all building walls, on the inside, to the nearest
foot. This should be for all 5 buildings, or labeled as Typ.
Number: 10 Created: 6/26/2007
[6/26/07] Topographic lines should not be shown on the Site Plan.
Number: 11 Created: 6/26/2007
16/26/07] The standard Owner's Certification, Notary Public, and Director
of Planning signature blocks must be included on the Site Plan, no later
than Final Development Plan submittal. An example of these signature
blocks is attached to this comment letter.
Number: 12 Created: 6/26/2007
[6/26/071 The lot(s) line along the public alley is getting lost in the multiple
lines in that location on the Site Plan.
Page 1