Loading...
HomeMy WebLinkAboutRIGDEN FARM, 11TH FILING, BROOKLYN PARK ROW HOUSES - FDP - 56-98AH - CORRESPONDENCE -REVISION ROUTING SHEET Item: Date Received: Planner: 5 r T Engineer: /Q/X,ec �/ie,&W Ckv of fort Coli ins CURRENT PLANNING Building Inspection oil ■■■■■■■■■ ■■■■■■■ Engineering Pavement Light& Power Natural Resources Street Oversizing Water &Water ■■■■■■■■■e■■■■■■ ................ If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours ZYuly, SC�teve OltW City Planner cc: Marc Virata Interwest Consulting Group King Surveyors Project File #56-98AH Page 3 Topic: Erosion Control Plan and Report Number: 70 Created: 9/30/2005 [9/30/051 1. Your calculations don't reflect the BMP's being utilized. Please correct. 2. On plan sheet #2, please delete the notes under the heading "Grading and Erosion Control Notes". The notes labeled "Standard Erosion and Sediment Control Construction Notes" are sufficient. 3. Per your report, there must be a note on the plan indicating seeding and mulching of all disturbed areas. 4. The plan needs a legend indicating BMP's being utilized. 5. What is protecting the east side of the development from sediment transport? 6. Etc. Topic: Utility Plans Number: 76 Created: 10/ 11 /2005 [ 10/ 11 /051 Please provide more spot elevations along the property boundary, in order to make sure that the site can be developed without getting on the neighboring properties, it seems that the construction of the storm line along the south property line might necessitate a temporary construction easement from the church. Number: 77 Created: 10/ 11 /2005 [ 10/ 11 /051 The detail of the tie in if the ADS pipe into the existing elliptical sewer should call for the existing HERCP pipe to be collared at the joint with the proposed ADS pipe, in order to make sure that this connection will be water tight. Department: Water Wastewater Issue Contact: Roger Buffington Topic: Utility Plans Number: 75 Created: 10/ 11 /2005 [ 10/ 11 /05] Change sanitary sewer manhole to 4 foot diameter. The mylars for this development proposal may now be submitted. Be sure and return all red -lined plans when you re -submit. Page 2 STAFF PROJECT REVIEW M. Torgerson Architects Date: 10/ 17/2005 c/o Troy Jones 223 North College Avenue Fort Collins, CO. 80524 Staff has reviewed your submittal for RIGDEN FARM, 11TH FILING, BROOKLYN PARS ROW HOUSES - FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Marc Virata Topic: Construction Plans Number: 72 Created: 10/5/2005 [10/5/05[ Provide a second benchmark for vertical control. Number: 74 Created: 10/5/2005 [10/5/05[ On Sheet 7 please rearrange the details such that the approval block can be located on the bottom right corner. Topic: Number: 73 Created: 10/5/2005 [10/5/05[ The Landscape Plan incorrectly indicates that a drive over grate is to be provided, presumably for use on top of the concrete pans in the drive aisles. Topic: Plat Number: 71 Created: 10/4/2005 [10/4/05[ The concept of the plat being entirely Lot 1, with Lot 1 including building envelopes, and all of Lot 1 being owned by maintained by the HOA is, I believe, unique. Would a title company have any issues with the underlying property in which a condo is defined being owned and maintained by the HOA? It is my understanding that the City Surveyor and consultant's surveyor discussed this situation recently. Department: Stormwater Utility Issue Contact: Basil Mandan Topic: Details Number: 78 Created: 10/ 11 /2005 [ 10/ 11 /051 Please change the detail subtitles to water details rather than storm water details. Page 1