HomeMy WebLinkAboutTRAILHEAD VILLAGE TOWNHOMES - PDP - 43-02C - CORRESPONDENCE - (3)The fire lane shall have appropriate maintenance agreements that are legally binding and enforceable, and be designated on the plat as an Emergency Access Easement. The minimum required width of 20 feet shall be maintained throughout the length of the fire lane. Number: 78 Created: 3/30/2006 [3/30/06] TURNING RADII: PFA acknowledges applicant's comment that minimum turning radii throughout the tracts is 25 feet inside, 50 feet outside. Number: 79 Created: 3/30/2006 [3/30/06] ADDRESSING: Address numerals and building letters shall be visible from the street fronting the property, and posted with a minimum of six-inch (6) numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). In addition, each individual unit shall also display its appropriate address numeral on both the "front" and "rear' of the unit. Number: 80 Created: 3/30/2006 [3/30/06] WATER SUPPLY: Fire hydrant(s) are required. Minimum spacing and flow requirements for this project are 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; Department: Transportation Planning Issue Contact: Kurt Ravenschlag Number: 66 Created: 3/29/2006 [3/29/06] Place any sidewalk outside of ROW in a public access easement. Department: Zoning Issue Contact: Jenny Nuckols Topic: ZONING Number: 3 Created: 10/21 /2005 [3/22106] [10/21/05] One handicap parking space needs to be van accessible and signed as such. Van accessible spaces are an overall width of 16'. 3-22-06 PLEASE NOTE ON THE SITE PLAN WHICH SPACE WILL BE VAN ACCESSIBLE Number: 7 Created: 10/24/2005 [3/22/06] [10/24/05) Page 3 of 3 - elevations - note building height, building materials and colors 3-22-06 Please note material colors Be sure and return all of your redlined plans when you bring revisions to us. You will not need to do another formal round of review. Please address the comments above and work with the reviewers individually to resolve. Once I hear back from everyone that they are OK with the plans, I will be ready to schedule the public hearing (administrative) for you. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6206. Sincerely, AA neWeln P City Planner Page 4 Number: 61 Created: 3/29/2006 [3/29/061 (PH) For any utility stubs that will be existing, please change the line type to existing and label as existing per Trail Head. Department: Light & Power Issue Contact: Alan Rutz Topic: General Number: 50 Created: 3/27/2006 [3/27/06] Continue to show the electric meter locations on the Overall Utility Plans. Please remove the electric lines. They will not be installed as shown on the Utility Plans. Number: 51 Created: 3/27/2006 [3/27/06] Streetlights are not installed on private drives unless requested by the developer. Number: 52 Created: 3/27/2006 [3/27/06] An electronic submittal, AutoCAD drawing, is required for the electric design. Drawing should consist of site plan, utility and landscape plans. Email drawing to arutz@fcgov.com Number: 53 Created: 3/27/2006 [3/27/06] Please relocate the following electric meters. On Overall Utility Plan Sheet G9 of G20. For Building A move meter to east end of building. For Building C move meter to east end of building. The gas meters will need to be moved to the west side of these buildings. Department: Natural Resources Issue Contact: Doug Moore Topic: Preliminary Landscape Plan Number: 54 Created: 3/28/2006 [3/28/06] Existing trees and buffer didn't print on plan and irrigated bluegrass seed or sod is incorectly shown within the buffer where native species need to be planned. Please also provide a native see schedule. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 76 Created: 3/30/2006 [3/30/06] SECONDARY ACCESS LANES: PFA acknowledges the two lanes shown to provide secondary access and are designated for "Emergency Vehicles Only'. These two easements shall be constructed of an all-weather driving surface (asphalt or concrete) that can support the weight of fire apparatus. The applicant said they would install a gate and Knox Lock at each of these access lanes; however, PFA would prefer signage only, and if private vehicles begin using the emergency access drives as a public street, then install a gate and Knox Lock. (All specifications for fire lanes shall apply to these two Emergency Access Easements; see comment 77 for information.) Number: 77 Created: 3/30/2006 [3/30/06] FIRE LANE: A fire lane is required throughout all drive aisles in Tracts F and G, and Green Lake Court and Flagstaff Court. The fire lane shall be visible by painting and signage, and maintained unobstructed. A fire lane plan shall be submitted for approval prior to installation. The fire lane shall be a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. Page 3 Number: 55 Created: 3/29/2006 [3/29/06] Provide ELCO, Boxelder, and Western Gas signature blocks on the plat. Number: 56 Created: 3/29/2006 [3/29/06] Property lines are shown encroaching into the Western Gas easement. No structures may be located in the easement, including footings. Number: 57 Created: 3/29/2006 [3/29/06] (PH) Please modify the Tract descriptions to say "PUBLIC access easement, not just "access easement." Number: 62 Created: 3/29/2006 [3/29/06] Horizontal control plan is not showing any labels or dimensions. Number: 67 Created: 3/29/2006 [3/29/06) (PH) Your key maps are still showing the old layout. Topic: grading plan Number: 58 Created: 3/29/2006 [3/29/06] (PH) Please clarify hatch patterns on the sidewalk and on the streets. Number: 65 Created: 3/29/2006 [3/29/06] (PH) The area on the west end of Green Lake Ct. appears to exceed the allowable drainage from a private drive onto a public ROW. The limit is 750 s.f. Topic: Landscape plan Number: 70 Created: 3/29/2006 [3/29/06] Please check with Excel that you're maintaining enough separation from street trees. Number: 71 Created: 3/29/2006 [3/29/06] (PH) Please label utility lines on the landscape plan. Also, label and dimension all easements. Topic: Technical Services Number: 74 Created: 3/29/2006 [3/29/06] Tech. Services Comments: 1. Boundaries close. Boundaries do not match Trail Head plat. (Does this plat change the south line of Lot 7/B18?) 2. Suggestion that line and curve tables be moved to the cover sheet. 3. Tracts should be emergency access also. Topic: utility plan Number: 59 Created: 3/29/2006 [3/29/06] Please check with utilities that you have adequate separations. Along Campfire Dr., only 3' between gas and water services. Along Vine Dr., only 5' between gas and electric mains. Number: 60 Created: 3/29/2006 [3/29/06] (PH) Label and dimension easements and ROW. Page 2 STAFF PROJECT REVIEW City of Fort Collins VF RIPLEY Date: 03/31/2006 AMY JOHNSON/CATHY MATHIS 401 WEST MOUNTAIN AVENUE, SUITE 201 FORT COLLINS, CO 80521 Staff has reviewed your submittal for TRAILHEAD VILLAGE TOWNHOMES PDP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Anne Aspen Topic: General Number: 69 Created: 3/29/2006 [3/29/06] 1 think the sidewalk solution works well, as does the new parking lot layout. Thanks for your time and effort to address these issues. Topic: Architectural Elevations Number: 72 Created: 3/29/2006 [3/29/06] Please submit material spec boards or label elevations with colors. Refer to 4.4(E)(4)(d) for more detail. Remember too that per 4.4(E)(4)( c) there need to be at least 3 distinctly different designs. Topic. Landscape plan Number: 73 Created: 3/29/2006 [3/29/06] The ring walkway is technically a major walkway spine and as such, needs to be lined on both sides with trees. Since the project is right up against the property line, there is little room to provide this. Perhaps you could add a few crabapples on the residential side. Number: 75 Created: 3/29/2006 [3/29/06) The parking that faces the existing trees and buffer needs to be screened. Again, since the project is right up against the property line, this may be challenging. Screening can either be taller shrubs or a combination fence and landscaping. My suggestion would be to change the parking spaces to compact dimensions and use shrubs for screening so that the view out to the trees is minimally obstructed. Number: 81 Created: 3/31/2006 [3/31/06] Ensure that the proposed street trees are properly spaced and not in the required utility separation areas. Topic: Lighting Plan Number: 68 Created: 3/29/2006 [3/29/06] The lighting plan is beautiful! 1 wish I had a gold star sticker to put on it. Good fixture_ choices, good lighting levels, and good shielding. Bravo!! Department: Engineering Issue Contact: Dan DelLaughter Topic. General Number: 32 Created: 11 /1 /2005 (3/29/06] [11/1/05] See redlines for additional minor revisions. Page 1