Loading...
HomeMy WebLinkAboutOLD TOWN NORTH - ODP - 28-99B - CORRESPONDENCE -STAFF PROJECT REVIEW City of Fort Collins BHA DESIGN Date:'02/15/2002_ RLISSELLLEE 4803 INNOVATION DR FT. COLLINS, CO 80525 Staff has reviewed your submittal for OLD TOWN NORTH ODFY - TYPE II #28-99B, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Troy Jones Topic: General 21 All three parcels (A,B, and C) have frontage on the future realigned Vine Drive. Typically it is the responsibility of a development to provide street trees on the adjacent streets. As each of the ODP parcels come in for development, the developments within each parcel must contribute to the cost of the street trees for future Vine Drive. Because the street is not going to be built for quite some time, the cost of the street trees will need to be escrowed for each filing abutting future Vine. Coordinate this with Sheri Wamhoff when you work out the development agreement language for the first filing PDP. 22 The pedestrian/bicycle crossing shown across parcel C benifits both parcel C and Parcel A. If parcel A does not contribute to the cost of this crossing, it would not be a proportionate amount of cost for few units being developed in parcel C to bear. As the approval of parcel A approaches the final stages, we need to discuss how this cost of the pedestrian/bicycle crossing can be shared between the two parcels (A & C). Please coordinate this in the development agreement language with Sheri Wamhoff. Department: Engineering Issue Contact: Sheri Wamhoff Topic: General 19 The future Redwood Drive should be solid black as it abuts all parcels of this ODP. As shown, it does not extend the solid black line all the way along parcel C. Extend this solid line to include the entire portion that abuts parcel C. 20 The dashed line portion of Redwood should not be labeled as "by others." Remove this in both locations where it is shown (in the legend, and next to the line itself). Department: Water Wastewater Issue Contact: Jeff Hill 18 Is the existing 12-inch water main to be lowered to accommodate the proposed box culvert? Provide all information necessary for the construction. Clearly define all connections on the existing and proposed 12-inch water main. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to cal eat (970) 2 1-6750. Y u s(TVru�ly, T Y i INEnSJ Cit Pl ner Page 1