HomeMy WebLinkAboutA - Z PARTY RENTAL - PDP - 11-99 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWsubmittals as of January 1999. Staff is requesting they be used on all current
development proposals. The applicant asked if the existing ditch could be lined or
a retaining wall installed to allow more use of the land. The flow rate needed to
design this would be one of the items the master plan would determine. Without
that, the site design engineer may have to determine that flow rate. There is some
older preliminary design information at the Utility Office but it does not use the new
precipitation rates. Please contact Glen Schlueter at 221-6589 with any questions
regarding these comments.
7. The Current Planning Department stated the following:
a. The I, Industrial District is described in Division 4.23 of the Land Use Code
(Article 4, pp. 152 - 160).
b. General Development Standards (such as parking and landscaping
requirements) are described in Article 3 of the Land Use Code.
C. In the event of a conflict between a standard or requirement contained in
Article 3 and Article 4, the standard in Article 4 shall prevail.
d. Pursuant to Section 2.2.2 of the Land Use Code, a neighborhood meeting
is nQt required if all land uses are subject to Administrative (Type 1) Review.
e. Please contact Ginger Dodge at 221-6750 to schedule -a 'develo`pment-
application submittal appointment:
Please contact the Current Planning Department at 221-6750 with any questions
regarding these comments.
3. The Water and Wastewater Utility stated that there is a 12-inch water main in
Riverside Avenue and an 8-inch water main between Riverside Avenue and
Academy Court. There are 8-inch and 15-inch sanitary sewer mains in Riverside
Avenue. The 8-inch sewer main is the closest to the subject property. A connection
should be made north of the existing manhole. The City's Water Conservation
Standards for Landscaping and Irrigation will apply. Water and Sewer Plant
Investment Fees (PIFs) and water rights will be due at the issuance of building
permit. Please contact Roger Buffington at 221-6681 with any questions regarding
these comments.
4. The Engineering Department stated that the Street Oversizing Fee for warehouse
uses is $0.74 per square foot. The fee for specialty retail is $3.95, per square foot.
Please contact Matt Baker at 224-6108 to determine the exact amount of the street
oversizing fee for the proposed use. A multi -modal Transportation Impact Study
(TIS) could be required. Please contact Eric Bracke (224-6062) and Kathleen
Reavis (224-6140) to discuss the parameters for the TIS. Additional right-of-way
may need to be dedicated along Riverside Avenue as 57.5 feet of right-of-way is
needed from the centerline of the Riverside Avenue to the property line for a 4-lane
arterial street. Standard Utility Plans and a development agreement will be
required. Curb, gutter and detached sidewalk is required along Riverside Avenue.
Drive aisles should intersect at 90 degree angles with Riverside Avenue.
Preliminary designs (horizontal and vertical alignment) for Riverside Avenue are
required for 1,000 feet beyond the limits of development. The Choice Streets
Program goes into effect on January 1, 1999. This program includes inspection
fees and paving requirements for cuts to existing streets. Additional comments will
be made during the review of the development application. Please contact Tim
Blandford at 221-6750 with any questions regarding these comments.
5. The Transportation Planning Department stated that if less than 50 peak hour
tN vehicle trips are generated by the site, there could be a partial or complete waiv_ef
�A16ssPL-'( of the requirement for a Transportation Impact Study. Bike parking must be
provided near the building entrances. Direct pedestrian connections must be
provided between the primary entrance(s) and the public sidewalk. Please contact
Kathleen Reavis at 224-6140 with any questions regarding these comments.
6. The Stormwater Utility stated that the property is located in the Spring Creek
Drainage Basin (inventory grid #11-J). The stormwater development fees for new
development in this basin are $2,175 per acre, subject to the runoff coefficient
reduction. The standard drainage and erosion control reports and plans are
required and they must be prepared by a professional engineer registered in
Colorado. Water quality must be addressed. Extended detention is the preferred
method. The Spring Creek Master Plan is being revised to address this area but
may not be completed by the time the site development plans are submitted.
Therefore, the standard detention requirement of a 2 year historic release rate with
a 100-year developed inflow is required. One-half of the adjacent street must be
detained on -site as well. The new precipitation rates will apply to any new
6gilCONCEPTUAL REVIEW STAFF COMMENTS
City of Fort Collins
MEETING DATE:
ITEM:
December 7, 1998
A-Z Party Rental.
APPLICANT: George Brelig
RBB Architecture, Planning, Interior Design
315 E. Mountain Avenue
Suite 100
Fort Collins, CO 80524-2913
LAND USE DATA: Request for a 10,000 square equipment rental establishment
on approximately 0.99 acres. The subject property is located
on the east side of Riverside Avenue between existing r
development at 1554 and 1608 Riverside. Y
COMMENTS:
1. The Zoning Department stated that the property is currently zoned I, Industrial o
District. Equipment rental establishments are permitted in the I, Industrial District °0 d
subject to Administrative (Type 1) Review. If additional uses are proposed for the
3,000 square foot "Tenant" space, please verify whether the proposed uses are i
permitted in the Industrial District subject to Type 1 or Type 2 review. If a mixture
of Type 1 and Type 2 land uses are proposed on the site, or if modifications of ,
standards are required, then the entire development application will be subject to
Planning and Zoning Board (Type 2) Review. A minimum 30,foot.deep landscaped
setback is required between the building and Riverside Avenue. A minimum 30 foot
deep landscaped setback is also required along the east property line as.it..adjoins
a non-residential district (POL) boundary line. Any outdoor storage areas must be
screened by solid fencing. Please contact Gary Lopez at 221-6750 with any
questions regarding these comments. 27,1 -6760
2. The Light and Power Utility stated that electric power is available from Riverside
Avenue. Please coordinate a transformer location with the Light and Power Utility
Engineering Department. The transformer must be located within 10 feet of a paved
surface. The Current Planning Department will also require screening of the
transformer. Normal development charges will apply. Any relocation of existing
electric facilities will be at the developers expense. Please have your electrician
submit a C-1, Commercial Use form to the Light and Power Utility. Please contact
Rob Irish at 221-6700 with any questions regarding these comments.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box580 Fort Collim, CO 80522-0580 (970)221-6750
CURRENT PLANNING DEPARTMENT
f � �
Commui.-,y Planning and Environmental L,ervices
Current Planning
DEC
City of Fort Collins
December 11, 1998
George Brelig
RBB Architecture, Planning, Interior Design
315 E. Mountain Avenue
Suite 100
Fort Collins, CO 80524-2913
Dear George,
For your information, attached is a copy of the Staffs comments concerning the A-Z Party
Rental, which was presented before the Conceptual Review Team on December 7, 1998.
This is a request for a 10,000 square equipment rental establishment on approximately
0.99 acres. The subject property is located on the east side of Riverside Avenue between
existing development at 1554 and 1608 Riverside.
The comments are offered informally by Staff to assist you in preparing the detailed
components of the project application. Modifications and additions to these comments may
be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the review
process, please feel free to call me at 221-6206.
Sincerely,
Michael Ludwig, AIC
City Planner
xc: Stormwater Utility
City Planner
File