HomeMy WebLinkAboutSOUTHGLEN PUD, 2ND FILING REPLAT - MAJOR AMENDMENT - 31-99A - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTm d c 0 m 5 0- E 0 U fr= L l 0 a) LO m =n .S . 0) Z Lu r�� Rj it�' b3z Z•% 3 ci } r.tlZC Gi2)> `/z(-39ciCr.yZ� G.Go f+a P = �J�� rED PEPv,16TF� Q.Z 4fS.23 > T rr7z• ,,V t r.v 1c Z34 �` SIP` �'��,e.z= 6•?G�+ Y� = iV1 pA/nnrJ� ^� n D, dlLr y (. e,; , ri A = cry...-I..�t.�l C"a, I.tl$6/0,orb (0,U) (060S24) (G.G)= ZZ.50 �F5 Grp : 1, L(4 tt 5 �0,11S) z/tip o.00sz{,) �1.39) : I.oI ifs F = (zsEPL),FT-wo Fern cc. , t-A/vi hG LI.Z, Fok Lct oA.)4> SttAn� p? lru. LF. t.f±dr&l t 1 f- 6 South Glen P.U.D. 2nd Filing Replat Jim Sell Design, Inc. 22237/11/02 EMS Table DA: Street capacity: Minor Event Theoretical capacity: Revised Mannings equation Q = 0.56'Z/n,S'*YW where: Q = theoretical gutter capacity Z = reciprocal of cross slope (ft/ft) n = roughness coeff. S = channel slope y = depth of flow at face of gutter )ft) Section z fVft n s ft/ft y ft Q cfs 3.58 0.013 0.00526 0.396 0.945815 B 10.2 0.013 0.00526 0.396 2.694781 C 10.2 0.013 0.00526 0.281 1.079492 D 50 0.013 0.00526 0.281 5.291627 Total theoretical Q = Qe + QA - Qr,+ Qn — 7.85 cfs Qa=al = Qtheoretical ; F where F = Reduction Factor from Fig 4-2 of the City of Fort Collins Drainage Criteria Manual, for S=0.00526ft/ft, F = 0.69 Total actual Q = 5.42 cfs -7 6, -,;, (',o e Oft 4 06 - 6(. a e-,ro — A 3 sq 444 ? C4 South Glen P.U.D. 2nd Filing Replat Jim Sell Design, Inc. 2223 7/11 /02 EMS Table CA: Summary of discharge calculations Basin ID Description Stewart I in/hr Fort Collins I in/hr Stewart I in/hr Fort Collins I in/hr Q2 (existing) cfs Q2 (revised) cis ,Percent.,:, j'.t,Change,z :>. 'VT(cfs) Q2 (existing) Q2 (revised) cfs Percent .,.Change :'" .=, .. (e +2.002.00 Percent 'Change QIOO (existing) cfs Q1oo (revised) (cis) Percent Change A 0.64 0.64 ,,, rt30.00.:..: 0.56 0.56 0.00 0.00 2.58 2.58 0.00 B 3.70 3.70 ;u•-,0:00: , .: 3.28 3.28 ...0.00. 13.87 13.87 0.00 15.47 15.47 0.00 C 3.06 3.14 ,2.62.-,,:- 3.67 3.77 ,.2;62 • 11.65 11.95 2.62 16.94 17.39 2.62 D 0.90 0.90 .::0.00e.;I ; 0.80 0.80 .,-,-,,0.00 2.69 2.69 0.00 3.72 3.72 0.00 E 0.38 0.38 < 0.00 ~ : , 0.33 0.33 3, - 0.00'. 1.37 1.37 .0.00 1.47 1.47 0.00 F 0.68 0.86 ;-,,26.40 ., , 0.60 0.75 26.40 .. ,. 2.71 3.42 26.40 2.79 3.53 26.40 SUM OF total going 9.35 9.61 , 2.77;.,=, 9.23 9.49 2.75 +1. 34.29 35.31 2.98 42.99 44.17 2.75 A -F topond) Difference 0.26 0.25 1.02 1.18 btwn existing and revised South Glen P.U.D. 2nd Filing Replat Jim Sell Design, Inc. 2223 7/11/02 EMS Table B.1: Runoff Coefficient Summary for existing condition (as referenced from 1996 JR report) Sub -Basin ID Description Area (ac) C2 C,M (=Ci 1.25) T2 min 12 (from Stewart) (inlhr 12 (Ft. Collins 99) Tim min I1W (from Stewart) IrN1r l,m (Ft. Collins 99) 02 (Stewart 1) cfs 02 (Ft. Collins 1) aim (Stewart 1) cfs aim (Ft. Collins I) A art 0.74 0.30 0.38 7.00 2.90 2.52 6.00 7.2 9.31 0.64 0.56 2.00 2.58 B art 1.88 0.82 1.03 11 2.4 2.13 9 7.2 8.03 3.70 3.28 13.87 15.47 Brevisedfrom C rom 2.6 0.56 0.70 7 2.1 2.52 6 6.4 9.31 3.06 3.67 11.65 16.94 6D rom 0.41 0.73 0.91 6 3 2.67 5 7.2 9.95 0.90 0.80 2.69 3.72 6E art 0.7 0.3 0.38 21 1.8 1.56 20 5.2 5.6 0.38 0.33 1.37 1.47 994 F from Stewartl 0.86 0.35 0.44 13 2.25 1.98 11 7.2 7.42 0.68 0.60 2.71 2.79 1994 Table B.2: Revised Runoff Coefficient Summary for Proposed Conditions, South Glen P.U.D. 2nd Filing Rapist Sub -Basin ID Description Area (ac C2 C1W (=Cz 1.25) T2 min 12 (from Stewart) in/hr 12 (Ft. Collins 99) Tim min 11W (from Stewart) INhr lim (Ft. Collins 99) O2 (Stewart 1) cts 02 (Ft. Collins 1) aim (Ft. Collins 1) kea A from Stewart 0.74 0.30 0.38 7.00 2.90 2.52 6.00 7.2 9.31 0.64 0.56 2.58 1994 B from Stewart 1.88 0.82 1.03 11 2.4 2.13 9 7.2 8.03 3.70 3.28 15.47 1994 C revised JSD 2.6 0.57 0.72 7 2.1 2.52 6 6.4 9.31 3.14 3.77 11.95 17.39 2002 D revised from 0.41 0.73 0.91 6 3 2.67 5 7.2 9.95 0.90 0.80 2.69 3.72 JR 1996 E from Stewart 0.7 0.3 0.38 21 1.8 1.56 20 5.2 5.6 0.38 0.33 1.37 1.47 1994 F revised JSD 0.86 0.44 0.55 13 2.25 1.98 11 7.2 7.42 0.86 0.75 3.42 3.53 2002 South Glen P.U.D. 2nd Filing Replat Jim Sell Design, Inc. 2223 7/11/02 EMS Table A.1: Runoff Coefficient Summary Sub -Basin ID Surface Description Area (sq ft) Area (ac) Total Area (ac) Area N Runoff Coefficienl Cf Weighted Runoff Coefficien Cf C (revised by Street 22906 0.53 20.22 0.90 0.18 R in 1996) Parking 18305 0.42 16.16 0.90 0.15 Buildings 17480 0.40 15.43 0.90 0.14 Grass/Open Space 54583 1.25 48.19 0.20 0.10 2.60 100.00 0.56 F (Stewart,'94) Impervious Area 0.11 12.79 1.00 0.13 Pervious Area 0.75 87.21 0.25 0.22 0.86 100.00 0.35 Table A.2: Revised Runoff Coefficient Summary for South Glen P.U.D. 2nd Filing Replat Sub -Basin ID Surface Description Area (sq ft) Area (ac) Total Area (ac) Area N Runoff Coefficient Ct Weighted Runoff Coefficien C, C (revised by Street 22906 0.53 20.22 0.90 0.18 SD in 2002) Parking 18305 0.42 16.16 0.90 0.15 Buildings 17480 0.40 15.43 0.90 0.14 Grass/Open Space 52643 1.21 46.47 0.20 0.09 House 1200 0.03 1.06 0.90 0.01 Parking 740 0.02 0.65 0.90 0.01 2.60 100.00 0.57 F (revised by Impervious Area 0.11 12.79 1.00 0.13 SD in 2002) Pervious Area 0.62 72.37 0.25 0.18 House 5240 0.12 13.99 0.90 0.13 Parking 320 0.01 0.85 0.90 0.01 0.86 1 100.00 0.44 E Glen Schlueter July 22, 2002 Page 3 of 3 G Minimizing the overlot grading will be a primary source of erosion control; however, erosion control, practices and devices will also be integrated with this plan so that the opportunities for' further erosion will _be reduced. A vehicle tracking control pad (20-feet by 20-feet) will be implemented at the access point to each lot. Silt fencing will be placed on the frontage of the three lots between the vehicle tracking control pads. 'Inlet protection will be placed at the 8-foot. Type R inlet north of the site on Albion Way south of the flowline. All erosion control measures are presented on the Drainage and Erosion Control Plan in the plan set. I hereby certify that this report (plan) for the drainage design of South Glen PUD 2nd Filing Replat was prepared by me (or under my direct supervision) in accordance with the provisions of City of Fort Collins Stormwater Utility Storm Drainage Design Criteria for the owners thereof. Thank you for your time in reviewing this letter report. If you have any questions, or require additional information, please do not hesitate,to call me. 9 Sincerely, Jim Sell Design, Inc. Kent Bruxvoort, P.E. Senior Engineer cc: Ed Stoner r E 0 F_VIROMCP MESV NM'223DOCADRAINAGE REPORTJ02.DOC v Glen Schlueter July 22, 2002. Page 2 of 3 year event (16.94 cfs to 17.39 cfs). Because the Rational Method cannot approximate runoff to this degree of accuracy,- we consider this increase in runoff to be negligible. Basin F, however, generates an additional 26 percent of runoff between the existing and proposed condition for both the 2-year event.(0.68 cfs to 0.86 cfs) and the 100-year event (2.79 cfs to 3.53 cfs). The increase in runoff for both Basins C and F are less than 1 cfs for the 2-year and 100-year events. A summary table presenting these discharges is included in°the appendix. A detention pond, as described in the 1994 Stewart report, collects runoff from the South Glen and the Park South neighborhoods, and releases into the New Mercer Canal. The JR report indicated that the contributing 2-year and 100-year discharge for the South Glen neighborhood is reduced by 0.67 cfs and 2.54 cfs, respectively, as a result of the South Glen PUD:5 h. Filing. The total increase in storm runoff from the South Glen neighborhood (Basins A, B; .C, D, E, and F) for the 2-year and 100-year*discharges with the 'intgnsities used in the Stewart (1994) report are 0.26 cfs and 1.02 cfs, respectively. Therefore, the total contributing runoff to the pond from the revised South Glen neighborhood (including the South Glen PUD 2°d Filing Replat) is less than the anticipated 2-year and 100-year runoff from the South Glen neighborhood when the pond was designed. Even though we feel that an increase in runoff of less than 1 cfs is negligible for this site, we analyzed Albion Way for -adequate street capacity for the minor and major events. The street has a capacity of 5.42 cfs and 16.22 cfs for the 2-year and 100-year events, respectively. The 2-year discharge for Basin C (3.77 cfs with 1999 Fort Collins intensity) is significantly less than the minor event street capacity.. Basin C has a 100-year discharge of 17.39 cfs; however, a storm inlet is placed roughly midway along Albion Way, so that significantly less than one-half of Basin C contributes to the inlet from the south. As a result, significantly less than half of Basin C 100-year runoff is expected to travel northward from the South Glen PUD 2°d Filing Replat project in Albion Way. Thus, street capacity on the west side of Albion Way in front of the replatted lots is acceptable. An existing 15-inch storm sewer collecting'runoff from an apartment parking lot west of the site will 'be relocated into a 10-foot drainage tract between Lots 1 and 2. The relocation of this line will require a 10-foot by 5-foot concrete box to intercept a 15-inch storm line -from the cul-de-sac at the end of Albion Way. The existing manhole located in the right-of-way in front of Lot 1 will be removed. The 18-inch RCP pipe draining the manhole will be extended southward to drain the 10-foot by 5-foot concrete box. The plan and profile drawings for the storm sewer realignment are presented on sheet 6 of the adjoining plan set. 9 °• @NROR:cr ELM ANWUMD0(STRAINAGF. RFPORT] 02DOC Ul VJ July 22, 2002 Glen Schlueter -City of City of Fort Collins Stormwater Utility P.O. Box 580. 700 Wood Street Fort Collins, CO 80522 4. ImndrcnpeAn•biteehnr Fixtinerinq _ Fraizvznmentnl 6- Cananmzity P(nnnu,y RE: Drainage and Erosion Control Letter Report for South Glen PUD 2°d Filing Replat Dear Glen: The South Glen PUD 2"d Filing Replat consists of three single-family lots in lieu of an existing pool and associated facilities. The three lots will face Albion Way and comprise a total area of 0.51 acres. The Storm Drainage Report for South Glen P.U.D. Fourth Filing (Stewart and Associates, August 1994) and- the Final Drainage and Erosion Control Report for South Glen PUD - 5th Filing (JR Engineering, Ltd., July 1996) were referenced for this report. ' The rational method, used to calculate storm discharges in the Stewart and JR reports, was also used to calculate the expected change in discharge as a result of the 2°d Filing Replat. The replat site was originally contained within Basins C and F in the 1994 Stewart Report. Basin C was revised in -the JR Engineering. 1996 report as a result of site layout changes for the South Glen PUD Fifth Filing. Furthermore, runoff coefficients for Basins C and F were revised as part of this replat to incorporate the decreased permeability of the proposed structures and driveways. The revised runoff coefficient calculations are Included in the appendix. The 1996 JR Engineering report referenced times of concentration from.the 1994 Stewart Report. ,pThe Stewart values for; time of concentration were also used in the modified South Glen PUD 2"d Filing Replat Basins C and F calculations because the proposed site changes result in negligible changes, in time of concentration paths. "Because the time, of concentration values did not change with the revised basins, rainfall intensities presented in the Stewart report were also used to calculate discharges. These discharges were then compared to determine the degree of impact to Basins C and F. The discharges.for Basins C and F were also calculated with revised intensities since the City of Fort Collins intensity -duration frequency curves have been modified since the preparation of the Stewart and JR reports. Additionally, revised intensities were used to calculate discharges from the Stewart report for basins not disturbed by this project for comparison purposes. Using 1999 City of Fort Collins intensities, runoff for Basin C increases by 2.62 percent between the existing and proposed condition for both the 2-year event (3.06 cfs to 3.14 cfs) and the 100- EAPROJECT FILES\LAND12M3\DOCS\DRAINAGE REPORT 7 M.DOC AIM SELL DESIGN, INC. 153 WEST MOUNTAIN AVENUE FORT COLLINS, COLORADO 80524 970484.1921 FAX: 970484.2443 JIMSELLDESIGN.COM