HomeMy WebLinkAboutOLD TOWN NORTH, NORTH FLATS - PDP & MODIFICATION OF STANDARDS - 28-99D - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTCross Section --Alley S-2 100-yr Event
Cross Section for Irregular Channel
Project Description
Worksheet
Alley S-2 100-yr
Flow Element
Irregular Channel
Method
Manning's Formula
Solve For
Channel Depth
Section Data
Mannings Coefficient
0.016
Channel Slope
0.006000 ft/ft
Water Surface Elevation
0.43 ft
Elevation Range
0.00 to 0.54
Discharge
9.00 cfs
?fo-sue A
0.55
0.50
0.40
0.30
0.20
0.10
0.00
-0+20.0
-0+15.0-0+10.0-0+05.0 0+00.0 0+05.0 0+10.0 0+15.0 0+20.0
V.20.0N
H:1
NTS
Project Engineer: JR Engineering
x:\3950000.all\3953500\alley s-2.fm2 JR Engineering FlowMaster v7.0 [7.0005]
11/20/06 03:33:01 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1666 Page 1 of 1
Alley S-2 100-yr Event
Worksheet for Irregular Channel
Project Description
Worksheet
Alley S-2 100-yr
Flow Element
Irregular Channel
Method
Manning's Formula
Solve For
Channel Depth
Input Data
Channel Slope 0.006000 ft/ft
Discharge 9.00 cfs
Options
Current Roughness Method Improved Lotter's Method
Open Channel Weighting Method Improved Lotter's Method
Closed Channel Weighting Metho. Horton's Method
Results
Mannings Coefficient
0.016
Water Surface Elevation
0.43 ft
Elevation Range 0.00 to 0.54
Flow Area
4.4 ft'
Wetted Perimeter
28.96 ft
Top Width
28.94 ft
Actual Depth
0.43 ft
Critical Elevation
0.42 ft
Critical Slope
0.007074 ft/ft
Velocity
2.05 ft/s
Velocity Head
0.07 ft
Specific Energy
0.49 ft
Froude Number
0.93
Flow Type
Subcritical
Roughness Segments
Start End
Mannings
Station Station
Coefficient
-0+20.0 0+18.5
0.016
Natural Channel Points
Station Elevation
(ft) (ft)
-0+20.0 0.54
-0+01.5 0.17
0+00.0 0.00
0+01.5 0.17
0+18.5 0.51
Project Engineer: JR Engineering
x:\3950000.all\3953500\alley s-2.fm2 JR Engineering FlowMaster v7.0 [7.0005]
11/20/06 03:32:54 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA +1-203-755-1666 Page 1 of 1
JR Engineering, Ltd.
2620 E. Prospect Rd., Ste. 190, Fort Collins, CO 80525
RATIONAL METHOD PEAK RUNOFF
(100-YEAR)
LOCATION:
NORTH FLATS
PROJECT NO:
39535.00
COMPUTATIONS BY:
ES
SUBN4ITTED BY:
JR ENGfNEERING, LTD.
DATE:
11/20/2006
100 yr storm, Cf = 1.25
DIRECTRUNOFF
I CARRYOVER
TOTAL
REMARKS
Des.
Point
Area
Design.
A
(ac)
C Cf
tc
(min)
i
(in/hr)
Q (100)
(cfs)
from
Design
Point
Q (100)
(cfs)
Olt 00)t0t
(cfs)
1
MF
0.09
0.91
5.0
10.0
1.01
1.0
2
SF
0.70
0.85
5.0
10.0
7.44
T4
3
ALLEY S-2
0.05
1.00
5.0
10.0
0.57
0.6
Q=CiA
Q = peak discharge (cfs)
C = runoff coefficient
I = rainfall intensity (in/hr) from IDF curve
A = drainage area (acres)
rota) = 9.0
I = 84.682 / (10+ tc)o 7975
39535.00 FLOW.XLS
JR Engineering, Ltd.
2620 E. Prospect Rd., Ste. 190, Fort Collins, CO 80525
RATIONAL METHOD PEAK RUNOFF
(10-YEAR)
LOCATION:
NORTH FLATS
PROJECT NO:
39535.00
COMPUTATIONS BY:
ES
SUBMITTED BY:
JR ENGINEERING, LTD.
DATE:
11/20/2006
10 yr storm, Cf = 1.00
DIRECT RUNOFF
CARRY OVER
TOTAL
REMARKS
Design
Point
Tributary
Sub -basin
A
(ac)
C Cf
tc
(min)
i
(in/hr)
Q (10)
(cfs)
from
Design
Point
Q (10)
(cfs)
Q(10)tot
(cfs)
MF
0.09
0.73
5.0
4.78
0.31
0.3
SF
0.70
0.68
6.0
4.55
2.17
2.2
ALLEY S-2
0.05
1.00
5.0
4.78
0.22
0.2
Q=CfCiA
Q = peak discharge (cfs)
C = runoff coefficient
Cf = frequency adjustment factor
I = rainfall intensity (in/hr) from OF curve
A = drainage area (acres)
I otas 2.1
I = 41,44 I (10+ tc)° 1174
39535.00 FLOW.XLS
LOCATION:
PROJ ECT NO:
COMPUTATIONS BY
SUBMIVULD BY:
DATE':
100-yr storm
NORTII FLATS
39535.00
ES
JR ENGINEERING, LTD.
1 1 /20/2006
Cf = 1.25
TOC-100
STANDARD FORM SF-2
TIME OF CONCENTRATION - 100 YR
SUB -BASIN
DATA
INITIAL /OVERLAND
TIME (ti)
TRAVEL TIME / GUTTER OR CHANNEL FLOW
(ft)
tc CHECK
(URBANIZED BASIN)
FINAL
tc
REMARKS
DESIGN
PONIT
SUBBASIN(s)
(1)
Area
(ac)
(2)
C
(3)
C'Cf
Length
(ft)
(4)
Slope
(%)
(5)
ti
(min)
(6)
Length
(ft)
(7)
Slope
(%)
(8)
n
Manning
rough.
Val.
(ft/s)
(9)
It
(min)
(10)
tc=
ti+tt
(11)
Total
(It)
(12)
tc=(1/180)+10
(min)
(13)
(min)
(14)
1
MF
0.09
0.73
0.91
40
2.0
1.7
90
0.6
0.016
1.6
0.96
2.7
130
10.7
5.0
2
SF
0.70
0.68
0.85
50
2.0
2.5
160
0.6
0.016
1.6
1.71
4.2
2101
11.2
5.0
3
ALLEY S-2
0.05
1.00
1.00
10
2.0
0.5
90
0.6
0.016
1.6
0.96
1.4
100110.6
5.0
EQUATIONS:
tc=ti+tt
ti=[1.87(1.1-CCf)L0.5)/S1/3
tt = Wel.
Velocity from Manning's Eqquation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual)
final tc = minimum of ti + tt and urbanized basin check
min. tc = 5 min. due to limits of OF curves
Page 2
JR Engineering, Ltd.
2620 E. Prospect Rd., Ste. 190, Fort Collins, CO 80525
LOCATION:
PROJECTNO:
COMPUTATIONS BY:
SUBMITTED BY:
DATE:
10-yr storm
NOWITI FLATS
39535.00
I? S
JR f NGINEFRING, LTD.
1 1 /20/2006
Cf = 1.00
STANDARD FORM SF-2
TIME OF CONCENTRATION - 10 YR
SUB -BASIN
DATA
INITIAL /OVERLAND
TIME (ti)
TRAVEL TIME / GUTTER OR CHANNEL FLOW
(tt)
tc CHECK
(URBANIZED BASIN)
FINAL
tc
REMARKS
DESIGN
PONIT
SUBBASIN(s)
(1)
Area
(ac)
(2)
C
(3)
Length
(ft)
(4)
Slope
(%)
(5)
ti
(min)
(6)
Length
(ft)
(7)
Slope
(%)
(8)
n
Manning
rough.
Vel.
(ft/s)
(9)
It
(min)
(10)
tc=
ti+it
(11)
Total
(ft)
(12)
tc=(1/180)+10
(min)
(13)
(min)
(14)
MF
0.09
0.73
40
2.0
3.3
90
0.6
0.016
1.6
0.96
4.3
130
10.7
5.0
SF
0.70
0.68
50
2.0
4.2
160
0.6
0.016
1.6
1.71
6.0
210
11.2
6.0
ALLEY S-2
0.04591
1
10
2.0
0+51
90
0.6
0.016
1.6
0.96
1.41
100
10.61
5.0
EQUATIONS:
tc=tl+tt
tl=[1.87(1.1- CC,) L0.5S1/3
It = Wel.
Velocity from Manning's Eqquation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual)
final tc = minimum of ti + It and urbanized basin check
min. tc = 5 min. due to limits of IDF curves
39535.00 FLOW.XLS
SUMMARY
DRAINAGE SUMMARY TABLE
Design
Point
Tributary
Sub -basin
Area
(ac)
C (10)
C (100)
tc (10)
(min)
tc (100)
(min)
Q(10)tot
(cfs)
Q(100)tot
(cfs)
DRAINAGE
STRUCTURE
/REMARKS
MF
0.09
0.73
0.91
5.0
5.0
0.3
1.0
SF
0.70
0.68
0.85
6.0
5.0
2.2
7.4
ALLEY S-2
0.05
1.00
1.00
1 5.0
5.0
0.2
1 0.6
9.0 TOTAL TO ALLEY S-2
Page 5
Client: .4 14
Project: .K,U
Subject: Vir"L
By: �Chk. By:
-Povv Is
- Job No: D-
- Date: 28 4 J-R ENGINEERINC
A Westrian Company
Sheet No: of
f
___3__
I
I
IT
E-11
LLL
F
_�
T
�
-�
I _
_I
1A,
SLY
F
110 AA
V 9
T
-
------
- - --
---
------
- ---------
1.
-
-I
F-
--
t
F-
646-01-98 Shear Engineering Corporation 12/21/2001
;dah Old Town North 9:15 AM
grmine Runoff Coefficients for Single Family and Town Home Lots
,e Family Lots
aDimensions 40.00 ft x 1 85.00 Ift
s 3400.00 sf = 0.08 ac.
s` Im A C A*C W
P A*%Im P
sf
8na,ding Area 1910 0.95 1814.50 100% 1910
Drive/ walks Area 405 0.95 384.75 100;- 405
Lawn Area = remainder 1085 0.10 108.50 0w 0
p-Jy^ Lot Area (A) = 3400 sf 2315
Total A*C = 2307.75
C2 = (Total/A) 0.68 % Impervious 68.09�
L100 = 1.25*C2 0.85 - C100 cannot be > 1
Roof Drives and walks
L x W = Area
ft ft sf
L x W = Area
ft ft sf
40.00 4.00 1160.00
15.00 3.00 1 45.00
8.00 25.00 1200.00
34.00
40.00
11360.00
25.00
22.00
1 550.00
Total
11910.00
Total 1405.00
Tow^l Home Lots
Lot Dim__-ion-s-----�70.00 ft x 18.00 ft
P_rea = 1260.00 sf = 0.03 ac.
A C A*C Imp A*Imp
sf
Building Area 970 0.95 921.50 100% 970
Drive/ walks Area 102 0.95 96.90 100% 102
La"fm Area = remainder 188 0.10 18.80 0% 0
Avg Lot Area (A)= 1260 1 19JL
Total A*C = 1037.20 % Impervious 85.08%
C2 = (Total/A) 0.82
C100 = 1.25*C2 1.00 - C100 cannot be > 1�
Roof Drives and walks
L x W = Area L x W= Area
ft ft sf ft ft sf
38.00 18.00 664.00 18.00 4.00 72.00
22.00 13.00 286.00 10.00 3.00 30.00
970.00
S.-
' �-rati0nal
r ocks Typ
Page 3 of 44
1 102.00
LOCATION:
North Flats
PROJECT NO:
39535.00
COMPUTATIONS BY:
E. SCHNEIDER
SUBMITTED BY:
JR ENGINEERING, LTD.
DATE:
9/28/2006
Updated Determination of Runoff Coefficients for Town Home Lots
Town Home Lots
Block Dimensions
Area
182 ft
15470 sf
A
sf
x
=
C
85
0.355
A*C
ft
ac
%I
A*%I
Roof Area
Asphalt Area
Paver Area
Sidewalk/concrete Area
Lawn Area = remainder
6463.2
0.95
6140.0
100
6463.16
2039.E
0.95
1937.6
100
2039.62
2910.0
0.95
2764.5
100
2910
36.0
0.95
34.2
100
36
4021.2
0.10
402.1
0
0
Avg Block Area (A)=
Total A*C=
C2 = (Total/A)
C100 = 1.25*C2
15470.0
% Impervious
11448.78
74.01
11278.5
0.73
0.91
Reference: "Final Drainage and Erosion Control Report for Old Town North Phase I"
Prepared by Shear Engineering Corporation, March, 2002
Conclusions: % Impervious of Town Home area decreased from original calculations (85% to 74%)
0siand ar Street — `
- I---- -
LEGEND
TOWN HOME BLOCK AREA
TOWN HOME ROOF AREA
--� TOWN HOME ASPHALT AREA
TOWN HOME PAVER/CONCRETE AREA
30 15 0 30
SCALE: 1" = 30'
TYPICAL TOWN HOME BLOCK
TO DETERMINE AREAS FOR %I
NORTH FLATS
SEPTEMBER 28, 2006
SHEET 01 OF 01
J•R ENGINEERING
A WrUlan Company
2620 East Prospect Road, Suite W • Port Couiri, CO 8053
07A—AGt-mma. c,,, o�a_omn .
September 29, 2006
J R ENGINEERING
A Westrian Company
Mr. Wes Lamarque
City of Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80522
RE: Drainage impact for changes to the Old Town North Phase 1 Development
Dear Wes:
We are pleased to submit for your review and approval this letter showing the drainage impacts from the
proposed changes to the townhome area of the Old Town North Phase 1 development. This area, named
North Flats, is the multi -family area located to the east and west of Blondel Street. The area will include
eight, two story, five-plex townhome units. Analysis of the proposed versus previously approved
conditions, as stated in the "Final Drainage and Erosion Control Report for Old Town North Phase 1"
dated March, 2002 and prepared by Shear Engineering Corporation, has indicated the percent
imperviousness for the townhome area would decrease by 11%. Therefore, stormwater runoff flows
would remain at or below previously approved conditions. Please refer to the attached spreadsheet and
drawing for calculations and information.
The area that includes alley S-2 was checked to ensure that during the major storm event, flooding of the
building located to the west of the southern half of alley S-2 would not occur. The area was chosen for
analysis because it is the area that takes the most flow during the major storm event. Our calculations
indicate that during the major storm event, flooding would not occur and the water surface elevation
would remain below the finish floor elevation of the adjacent building and within the existing drainage
easement. Please refer to the attached spreadsheet for these calculations.
JR Engineering has reviewed and concluded that the impact to the local drainage basin is improved and
negative impacts are not anticipated to the surrounding areas due to the proposed improvements. All
computations within this letter have been completed in compliance with the most recent rainfall data and
the City of Fort Collins Storm Drainage Design Criteria.
We appreciate your time and consideration in reviewing this submittal. If you have any questions or need
additional information please call (970) 491-9888.
Prepared by:
9�k�
Erika Schneider
Project Engineer
Reviewed by:
Joseph C. Sparone P.E.
Project Manager
0�'°,aoo uC
2620 East Prospect Road, Suite 190, Fort Collins, CO 80525 X:\3950000.all\3953500\Word\Letters\Drainage Letter.doc
970-491-9888 • Fax: 970-491-9984 • wJrengineering.com