Loading...
HomeMy WebLinkAbout607 COWAN ST. - PDP - 35-99 - CORRESPONDENCE - (4)No Text 25. Coordinate the sidewalk system through out the development with Transportation Planning Services. Additional comments and the required number of revised plans may be forthcoming as the various departments and reviewing agencies continue to review this request. Please provide a written response to each of the above comments with the submittal of plan revisions. In addition, a revised site development plan drawn to scale which is clearly dated and labeled shall be submitted to address the above. Section 2.2.11 of the Land Use Code requires that an applicant submit revisions based on this letter within 90 days or the project application becomes null and void. Your response to the City's concerns is due by March 21, 2000. A 30-day extension to this deadline is available. Request for an extension should be directed to the Current Planning Director. If remaining issues are those that do not require plan revisions, a status report verifying continuing efforts toward resolving the issues is required within the same timeline. The burden of demonstrating compliance with all Land Use Code criteria is with the applicant. Please contact me at 970.221.6750 and/or e-mail: rfuchsPci.fort-collins.co.us if you should have any questions or concerns related to these comments. Sincerely, 1A i> Ronald G. Fuchs City Planner cc: Current Planning File #35-99 D:\My DocumentstPlanning Documentwlyrtle Court #35-99Unyrtle court first filing comments.doc Page 7 of 7 architectural feature may not exceed 24:12 and the covered porch may be flat whenever the roof of such porch is also considered to be the floor of a second -story deck. All roof pitches shall be shown on all building elevations. i) Per Section 4.7(F)(3) requires that whenever a lot has frontage along an alley, any new off-street parking area located on such lot must obtain access from such adjoining alley; provided, however, that such alley access shall not be required when a new detached garage is proposed to be accessed from an existing driveway that has a curbcut along a public street, or when alley access is determined by the City Engineer to be a hazard to persons or vehicles. This standard has not been met. j) Per Section 4.7(F)(4) site design permanent open off-street parking areas for all permitted principal uses, other than single-family dwellings, shall not be located any closer to a public street right-of-way than the distance by which the principal building is set back from the street right-of-way. This provision shall not be construed to preclude temporary parking in driveways. It is unclear to staff if this standard is met. 15. Since the site is located within the neighborhood sign district, please indicate type of signage. .16. Please clarify on the plan legend the respective individual track and open space areas. 17. Please show the location of all transformers on the revised Site and Landscape Plans. They must be located no more than 10 feet from a paved surface and must be screened from view. 18. Please provide a detailed light plan (spec. sheet for all wall and pole mounted fixtures) insuring that all lighting apparatuses are shielded down, which meets Section 3.2.2(D)(3)(e) and 3.2.4(A) — (D). a) According to Section 3.2.4(D)(7) a maximum of 10 foot-candles is allowed at any single point as result of on -site lighting. According to Section 3.2.4(D)(8) of the Land Use Code, lighting levels shall not exceed 0.1 foot-candle at a point 20 feet beyond the property line as a direct result of on -site lighting. 19. Please show the location of all transformers on the revised Site and Landscape Plans. They must be located no more than 10 feet from a paved surface and must be screened from view. 20. Verification of the irrigation system connection points to ensure all landscaping is continuously maintained per Section 3.2.1 [J]. 21. All signs will require an additional sign permit outside this comment review. 22. Please note all exterior mechanical devises, meters, et cetera, must be screened. 23. Please label the sheet plan sets Sheet 1 of 5, Sheet 2 of 5, et cetera in the lower right hand corner of each applicable sheet. 24. Return all redlined documents with plan revisions, including all redlined plans with Current Planning comments. Page 6 of 7 h) Please indicate and label all building elevations, such as: Building A — north elevation, south elevation, east elevation, and west elevation; Building B — north elevation, south elevation, east elevation, and west elevation; and, et cetera. i) Scaled design elevations for all proposed structures need to be submitted and must be compatible with the overall development based upon Land Use Code standards including Section 3.4.7 Historic and Cultural Resources. j) Scaled design elevations for the trash enclosures and all building elevations need to be submitted. 14. The following comments apply to the Neighborhood Conservation, Medium Density District (N-C-M) (LUC Section 4.7): a) It is unclear if Section 4.7 (D) Land Use Standards (1) Density/Intensity of Development is met -with this project development plan. The Land Use Code requires that the minimum lot area shall be the equivalent of two (2) times the total floor area of the building(s), but not less than the following: five thousand (5,000) square feet for a single-family or two-family dwelling and six thousand (6,000) square feet for all other uses. For the purposes of this subsection, "total floor area" shall mean the total gross floor area of all principal buildings as measured along the outside walls of such buildings, including each finished or unfinished floor level, plus the total gross floor area of the ground floor of any accessory building larger than one hundred twenty (120) square feet, plus that portion of the floor area of any second story having a ceiling height of at least eight (8) feet located within any such accessory building located on the lot. (Open balconies and basements shall not be counted as floor area). b) Per Section 4.7(E) (3) Minimum rear yard setback shall be five (5) feet from existing alleys and fifteen (15) feet in all other conditions. c) Per. Section 4.7(F)(1)(b) the primary entrance to a dwelling shall be located along the front wall of the building, unless otherwise required for handicap access. Such entrance shall include an architectural feature such as a porch, landing or portico. d) Per Section 4.7(F)(1)(c) accessory buildings and attached garages shall have a front yard setback that is at least ten (10) feet greater than the front setback of the principal building that is located on the front portion of the lot. e) Per Section 4.7(F)(1)(d) a rooftop or second floor addition shall not overhang the lower front or side exterior walls of the existing building. f) Per Section 4.7(F)(1)(e) front porches -shall be limited to one (1) story, and the front facades of all one- and two-family dwellings shall be no higher than two (2) stories. g) Per Section 4.7(F)(1)(f) in the event that a new dwelling is proposed to be constructed on the rear portion of a lot which has frontage on two (2) streets and an alley, the front of such new dwelling shall face the street. h) Per Section 4.7(F)(1)(g) the minimum pitch of the roof of any building shall be 2:12 and the maximum pitch of the roof of any building shall be 12:12, except that additions to existing dwelling units may be constructed with a pitch that matches any roof pitch of the existing dwelling unit. Additionally, the roof pitch of a dormer, turret or similar Page 5 of 7 rack. Then, these areas can receive special landscaping treatment to minimize their visual impact. m) Section 3.2.2(C)(5) and 3.2.2(D) requires that six-foot walkways within the site provide direct well direct well-defined and separated circulation routes for vehicles, bicycles, and pedestrians (please coordinate with Transportation Planning). All pedestrian ways and sidewalk widths shall be shown on the respective plans. n) Surrounding the multi -family unit footprints, shrubs and perennial plants shall be shown on the site and noted in the legend. o) Per Section 3.2.2(J) requires the vehicular use area be set back from a property line with a five (5) foot landscape strip. The west and east property lines adjacent to the vehicle parking areas do not provide a sufficient five- (5) foot landscape strip. Please clarify if there is a collective parking arrangement (recorded joint access agreement), if existing or proposed, this agreement shall be submitted and included with this Project Development Plan. p) In order to verify the actual number of parking spaces required for this project development plan, additional information shall be submitted by means of a data table and floor plans. This information is required in order to comply with LUC Section 3.2.2(K). 13. The following comments apply to the architectural elevations: a) All single-family dwelling elevations shall comply with LUC Section 3.8.15. b) Section 3.5.1(A)-(H) requires a multi -family structure to achieve a compatible design characteristic throughout. It is unclear to staff if this has been met since the plans submitted do not show all residential building elevations and there appears.to be two (2) typical building footprints (two -unit and four -unit). Please indicate on the elevations the height of the ridgelines, eaves, roof pitch, et cetera. c) Please indicate all building dimensions, including doors, windows, and et cetera on the building elevations. d) Per Section 3.5.2(C)(1) requires that every multi -family front facade with a primary entrance to a dwelling unit shall face the adjacent street to the maximum extent practicable. Every front facade with a primary entrance to a dwelling unit shall face a connecting walkway with no primary entrance more than two hundred (200) feet from a street sidewalk. e) Per Section 3.5.2(C)(2) requires that every. building containing four (4) or more dwelling units shall have at least one (1) building entry or doorway facing any adjacent street that is smaller than a full arterial or has on -street parking. f) Per LUC Section 3.5.2(E)(4) - (F) the design of the garage must be sensitive to the overall development. Detail elevations shall be submitted. g) Please indicate all building colors (stone, bricks, et cetera) on the Building Elevations in accordance with Section 3.5.1(G) of the Land Use Code. Page 4 of 7 driveway locations and utilities shall be shown to ensure compliance with the Land Use Code. b) After revising the site/landscape, please make sure the minimum species diversity is provided in accordance with Section 3.2.1(D)(3) of the Land Use Code. c) The landscape plan shall include all proposed vegetation, species and size. Per Section 3.2.1(E)(2) landscape areas are those areas on the site that are not covered by buildings, structures, paving or impervious surface. . d) Per LUC Section 3.2.1(E)(4)(a) multi -family parking lot perimeter landscaping requires that trees be provided at a ratio of one (1) tree per twenty-five (25) lineal feet along a public street and one (1) tree per forty (40) lineal feet along a lot line parking setback area. e) Please note that LUC Section 3.2. 1 (E)(4)(b) addresses the need to screen parking areas and needs to be addressed with this project development plan. f) Per Section 3.2.2(M) and Section 3.2.1(E)(4) — (6) requires at least six (6) percent and/or ten (10) percent of the interior space of any multi -family parking lot is devoted to interior parking landscaping. The actual interior parking lot landscaping percentages have not been shown. Specifically, all parking lots need to meet the parameters addressed in LUC Section 3.2.1(5)(E)(a) — (e) including 3.2.2(B)(5)(a) walkways shall have one (1) canopy shade tree per forty (40) lineal feet of walkways planted in a . landscape strip within five (5) feet of such walkway. g) Per Section 3.2.1(E)(5)(c) parking lot landscaping shall be protected with concrete curbing. The required raised concrete curbs shall be shown on the site plan. h) The Land Use Code per Section 3.2.1(E)(6) requires that landscape and building elements be incorporated to screen the trash enclosures. A revised plan shall be submitted to meet these standards, including scaled design elevations of the enclosures. i) Please clarify, it appears that some of the existing trees may be removed with this proposed Project Development Plan and per LUC Sections 3.2.1(F) — (H) a detailed tree mitigation plan shall be submitted for review by the City. j) Address all visual clearance and sight distance triangle areas per Section 3.2.1(L) of the - Land Use Code. k) According to Section 3.2.2(C)(3) site amenities such as benches, bike racks, et cetera should be provided. Please show site amenities in the respective parks and open spaces. 1) Per Section 3.2.2(C)(4) please provide more bike racks at a ratio of at least one per multi -family building located near the entrance but out of the way of pedestrian walkways. Please add the bike rack locations to the Landscape Plan so there are no conflicts with shade trees. A good idea may be to establish the location of the electrical transformers, phone and cable t.v. pedestals and combine these facilities with the bike Page 3 of 7 P. Engineering/Pavement: Q. Mapping/Drafting: R. Engineering: S. Current Planning Department: provides the following: 1. Delineate all property lines and all rights -of -way improvements and widths and sidewalk widths on all plans. The plan shall include Cowan Street and Myrtle Street rights -of -way widths and improvements, alleys width and improvements, and sidewalk widths internal and abutting this project development plan. This information shall be included on all plans as required by the City of Fort Collins Development Manual. 2. The plan sets need to include building envelope/footprint dimensions and distance to nearest property lines as required by the City of Fort Collins Development Manual. 3. Please label the sheet plan sets Sheet 1 of 5±, Sheet 2 of 5±, et cetera in the lower right hand corner of each applicable sheet. 4. The plan set needs to include reference to the Index of Drawings on the first plan sheet page. 5. Provide an overall site plan showing the proposed site plan in relation to the surrounding area. This plan shall include an area beyond the property lines of the.proposal showing the area and uses within five hundred (500') feet o the proposal, exclusive of public right-of- way, at the same scale of the underlying proposal as required by the City of Fort Collins Development Manual. All plan set shall reference the project development plan. 6. The north arrow shall be shown on all respective plans as required by the City of Fort Collins Development Manual. 7. Existing and surrounding zoning shall be shown as required by the City of Fort Collins Development Manual. 8. All plans, diagrams and illustrative elevations shall include the appropriate verifiable scale. The overall site plan, site plan, and landscape plans shall utilize the same scale. 9. Site and Landscape Maintenance Agreements shall be submitted. 10. Please provide a formatted breakdown of densities per LUC Section 3.8.18 Gross Residential Acreage. Please provide diagrams clarifying how gross and net density were figured. 11. Clarification shall be submitted showing the proposed ownership of all dwelling units. 12. The following comments apply to the Site/Landscape Plan: a) Per LUC Section 3.2.1(D)(2) street trees shall be placed at thirty-foot to forty -foot spacing intervals in the center of all parkway areas (the parkway strip shall be in accordance with Design and Construction Criteria, Standards and Specifications for Streets, Streetscapes, Sidewalks, Alleys and Other Public Ways). The trees shall be placed at least eight (8) feet away from the edges of driveways and alleys, and forty feet (shade trees)/fifteen feet (ornamental trees) (LUC 3.2.1(K) from any street light. All Page 2 of 7 Commi y Planning and Environmental rvices Current Planning City of Fort Collins December 22, 1999 Mr. Mark Brannon Cowan Street Properties, LLC 2701 Alcott Street #485 Denver, CO 80211 RE: Myrtle Court Project Development Plan Dear Mr. Brannon: This letter is in response to plans for Myrtle Court Project Development Plan (Planning File #35-99) submitted on November 17, 1999. Please note that staff reviewed your plans and the Planning Division mailed a request for comments to several public agencies and departments. This development proposal is subject to and shall comply with all requirements set forth in the City's Land Use Code (LUC), specifically: Articles 2. Administration (Development Review Procedures); Article 3. General Development Standards; and, Article 4. (Zoning] Districts. The City of Fort Collins Land Use Code (LUC) requires that throughout all land use proceedings, the burden to comply with all applicable standards rest with the applicant. Staff, after reviewing materials submitted by the applicant, finds that revisions/re-design to the submitted plans dated 8.25.99 and 9/21/99 are warranted to meet the Viand Use Code. The following lists the agencies and departments that responded and the substance of their comments: A. Traffic Operations: submitted a checklist that identified several requirements. The checklist is attached to this report. B. Advance Planning: returned the checklist. C. Forestry: submitted a checklist that identified several requirements. The checklist is attached to this report. D. Park Planning: returned the checklist with their comments. E. Cable TV: submitted a response to the checklist and it is attached to this report. F. Water Conservation: responded back with their comments. G. Natural Resources: submitted a checklist that identified several requirements. The checklist is attached to this report. H. Post Office: returned their comment sheet. I. Light and Power: submitted a checklist that identified several requirements. The checklist is attached to this report. J. Public Service/New Century Energies: returned their comment sheet. K. PFA/Poudre Fire Authority: submitted a response to the checklist and it is attached to this report. L. Building Inspections: submitted a response to the checklist and it is attached to this report. M. Zoning: submitted a checklist that identified several requirements. The checklist is attached to this report. N. Stormwater: O. Transportation Planning: 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020