Project: HFROKGHT5
Planner: CAr4,5--�ot1 c`o-s TrafOcOperations:
Engineer. Vl ew
Items Requested
Site land I Plat I Utility F-2�yther Items
X u �.
�r/wastewate x I < I -.y- Ix
Ic Operadons
s. Planning
it Resources " I I 1 J
Planning
Other:
Note: All redlined Items should be returned with the resubmlMV revisions.
Date:
Redlined Items Being Returned
Site I Land I Plat I Utility Draina e
xI�i/lam
Other items Being Returned
55
Please remove water quality outlet structure detail on sheet 14 due to a
modified structure being proposed. If purpose is to show well screen and
orifices, than mark out and note only pertinent information.
Department: Water Wastewater Issue Contact: Jeff Hill
24
Repeat Comment 9/17/02 Show locations of gas and electric on the overall utility
plan. The location proposed for electric and gas is not the usual location. Has gas
and electric approved these locations? Perhaps electric and gas need to have a
sign off area on this plan.
Topic: General
57
No water services are permitted on a dead end water main beyond the last
fire hydrant,
58
Provide full concrete encasement on the existing 8-inch sanitary sewer main
if the proposed water main cross below or within 18-inches vertically of the
sanitary sewer main.
59
Multiple landscape plans are confusing. Provide only one landscape plan for
this project.
See site, landscape and utility plans for other comments,
Please return all of your redlined plans when you re -submit. As soon as the above
issues are satisfactorily addressed, final mylar copies of the plans may be submitted
for recordation.
If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at (970) 221-6750.
Sincerely,
AMERON GLOSS
Current Planning Director
Page 2
STAFF PROJECT REVIEW
CAvof Fort Collins
Torgerson Architects Date: 9/25/2002
Mikal Torgerson
211 Jefferson
Fort Collins, CO 80524
Staff has reviewed your submittal for CHEROKEE FLYING HEIGHTS Final
Compliance #17-00/13, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Cameron Gloss
Topic: General
56
No requirements for the Final Compliance Review
Department: Engineering Issue Contact: Marc Virata
Topic: General
62
The landscape plans appear to show a street light (by way of symbol) proposed
within the western boundary. of the additional right-of-way granted for Taft Hill Road.
This or any other permanent type of structure should be relocated away from right-
of-way. Ensure that information is coordinated between site, landscape, and utility
plans.
63
Attached is an "Information for Development Agreements” Sheet which should be
filled out in order to begin the Development Agreement process.
Topic: Utility Plans
60
Previous redlines were apparently not received. These would be helpful to ensure
any minor comments not typed on DMS but documented on redlines were
addressed.
61
This project was formally submitted and is required to be reviewed under older
Street Standards. Engineering would like the applicant/engineer to look at providing
a radius style driveway (20' radii) off of Taft Hill Road (which would be required
under the new street standards) instead of the driveway pan. Engineering views it
as an advantage to allow faster turning movements off of Taft Hill Road.
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
54
Please see comment in drainage report,