August 24, 2000 ► 6cannis"Road
Alphar0c,r'"b
30005
Jim Temple
VoiceStreatn Wireless Ta''7770.2631°°
2323 Delguy St. ww:no.zac.3lso
Denver, CO 80216 www.releseucture�.com
Please find attached drawings of our 604 UniPole System. Please note the
weak link joint at the 4041. height, which is a safety option on our pole. The
weak link joint ensures that in the unlikely event of a structural collapse, the
unit will fail at this point to reduce the radius of the impact zone from 60 ft.
to 20 ft. I should also point out that our UniPoles are usually loaded with
coaxial eablo and grounding lines, making the detachment of the upper
portion of the pole highly improbable. Please let nie know ii'you have any
questions or comments.
With best regards,
Sam Saleb40
Design Engineer