This subdivision plat request is scheduled to go to an administrative public hearing before a
hearing officer on Thursday, October 11, 2001, at 3:00 p.m., in conference room 'A' at
281 North College Avenue (see attached notification letter).
Please submit 5 copies of the subdivision plat reflecting all changes made in response to
this comment letter by Monday, October 8, 2001. Be sure and return all of your red -lined
plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Yours Truly,
OTEVOEOLV.-
City Planner
Page 4
n
Department: Engineering
11
Issue Contact: Katie Moore
A Development Agreement will be needed due to stormwater concerns.
15
Issue Contact: Katie Moore
Please correct the typos as redlined.
Department: Light & Power
2
Issue Contact: Bruce Vogel
No Comments
Department: Natural Resources
g
Issue Contact: Doug Moore
No Issues -
Department: PFA
g
Issue Contact: Michael Chavez
No Comment at this time.
Department: Police
3
Issue Contact: Joseph Gerdom
No Comments
Department: Stormwater Utility
16
Issue Contact: Wes Lamarque
The analysis performed by Ayres and Associates is agreed upon by the stormwater
utility. Before a building permit is issued,
a grading and erosion control plan is needed
for review.
Department: Zoning
1
Issue Contact: Jenny Nuckols
No Comments
Page 3
Water/Wastewater Department
1. Are the adjacent lots in the Wildwood Subdivision Lots 9 & 10, as shown, or 10 &
11 (see the plat of Wildwood Subdivision, 1st Filing).
Technical Services Department
The outside boundary and legal description do close. There are 2 calls in the
legal description that do not match the boundary.
2. There is a typo error in the legal description. The section # is incorrect.
3. The Southwest Corner, as described, does not match the City's records.
AT&T Broadband
1. AT&T Broadband would like to see the existing 6' wide utility easement along
Cedarwood Drive continue south through Lot 1. Also, can the existing 10' wide
utility easement at the northwest corner of the Elbrader Subdivision be continued
to the south, along the west side of this lot?
The Building Inspection Department has no comments.
The Advance Planning Department has no comments.
The Post Office has no comments.
Excel Energy (Public Service) has no comments.
17
Issue Contact: Steve Olt
Katie Moore of the Engineering Department indicated that there are typographical errors
on the subdivision plat.
18
Issue Contact: Steve Olt
Katie Moore of the Engineering Department indicated that the City's Technical Services
Department has some concerns regarding the subdivision plat. These concerns must be
addressed before the plat can be recorded.
19
Issue Contact: Steve Olt
Wes Lamarque of the Stormwater Utility indicated that the subdivision plat for the
property is not making the proposed storm drainage conditions any worse than the
existing conditions.
Page 2
aSTAFF PROJECT REVIEW
City of Fort Collins
AYRES ASSOC.
BRIAN NELSON
3665 JEK PKWY. BLDG 2, #200
FT. COLLINS, CO 80525
Date: 9/26/01
Staff has reviewed your submittal for ELBRADER REPLAT, TYPE 1 (LUC) #21-01, and we
offer the following comments:
ISSUES:
Department: Current Planning
12
Issue Contact: Steve Olt
The following comments were received from the identified departments and outside
reviewing agencies:
City Right -Of -Way Department
The sanitary sewer easement is recorded in Larimer County @ Reception
#96054959. A copy of this Deed of Easement is attached.
Stormwater Utility
The applicant's engineer should refer to the Prospect Road S.I.D. drainage study
This may determine if on -site detention is required. The standard is to detain for
100-year runoff and release at the 2-year historic rate.
2. Water quality extended detention is also required to treat runoff prior to it being
discharged off -site.
3. The grading along lot lines with adjacent properties is usually critical in these in -
fill situations; therefore, some off -site contours and spot elevations will be
needed to correctly verify grading.
4. The entire site is located in a low-lying area which receives runoff from a
drainage area to the west. Development on this property may cause a rise
in the 100-year water surface elevation, which would impact surrounding
buildings. This could result in the property being difficult to develop and
will require additional analysis. Otherwise, the standard drainage and erosion
control report is required and must be prepared by a professional engineer
registered in the State of Colorado. The report will need to be approved prior to
release of a building permit.