HomeMy WebLinkAboutSPANJER OFFICE BUILDING - PDP - 25-01 - CORRESPONDENCE - (6)Water Supply - No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 97 UFC 901.2.2.2 92 Water Supply requirment still need to be addressed. The location of the fire hydrant needs to be on the site plan.. Department: Police Issue Contact: Joseph Gerdom 90 The lighting plan needs to be reworked to provide greater security and less light spillage. Every lot has inadequate lighting with several also having excess. Topic: Landscape Plan 132 No lighting information to evaluate landscaping/lighting impacts on security and safety issues. Topic: Plat 144 5/28: Review of Site Lighting Plan: Plan shows no lighting level grid (foot candle), no lighting at access points, or lighting in parking lot. Department: Stormwater Utility Topic: Drainage 134 No comments. Department: Transportation Planning Topic: Site Plan 142 no comments Issue Contact: Wes Lamarque Issue Contact: Kathleen Reavis Department: Zoning Issue Contact: Jenny Nuckols Topic: General 131 See plant note #10 - it is referencing the Town of Johnstown Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, STEVE OLT City Planner Page 3 Rick Lee of the Building Department indicated that he is forwarding a copy of the various codes that the City Building Department will enforce. From the brief information provided it is apparent that some of the exterior walls of the office building and storage building will need to be one -hour construction per Table 5-A. These rated walls must be carried to the roof deck above. 89 Current Planning's comments are on red -lined plans that are being forwarded to the applicant. Department: Engineering Issue Contact: Susan Joy Topic: Plat 143 4/19/02: Not necessary to show the temporary easements on the plat, however, if it is preferred that it is, the owner of lot 6 will have to sign off on the plat. Please provide the temp easement by separate document or, at the very least, a letter of intent prior to the public hearing - see attached. Topic: Utility Plans 141 4/19/02: Please contact Mike Chavez with PFA at 416-2869 for their requirements on bollards in the emergancy fire access. 5/28/02: Please see attached specifications for the bollards required by PFA. Please change the Landscape, Site, and Utility plans from the chains/bollards to one of the two systems spec'd. Department: Light & Power Issue Contact: Alan Rutz 93 Contact Light & Power with electric load requirements. Department: Natural Resources Issue Contact: Doug Moore Topic: Natural Resources 74 Trash Enclosure - Please include a detail of the trash enclosure with the next submittal. *** REPEATED COMMENT 1/1612002 *** Department: PFA Issue Contact: Michael Chavez 58 Address Numerals - Address numerals shall be visible from the street fronting the property,and posted with a minimum of 6-inch numerals on a contrasting background. 97 UFC 901.4.4 59 Page 2 STAFF PROJECT REVIEW Citv of Fort Collins Land Images Date: 5/30/2002 Trista Sigler 215 W. Magnolia St. 202 Fort Collins, CO 80521 Staff has reviewed your submittal for SPANJER OFFICE BUILDING, #25-01, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt 75 Robert Lopez of AT&T Broadband (cable TV) indicated that they have fiber optic line on the west side of South College Avenue from Harmony Road to Cameron Drive, then it crosses to the east side of College Avenue. 76 Len Hilderbrand of Excel Energy (Public Service) indicated that no trees may be planted within 4' of gas lines. 77 A copy of a comment letter received from Terry Farrill of the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District is attached to this comment letter. 78 Tim Buchanan, the City Forester, indicated that the Landscape Plan has 3 Autumn Blaze Maple trees as street trees between the sidewalk and curb. This species (Autumn Blaze Maple) is not on the "City Street Tree List". The applicant needs to change the Autumn Blaze Maples to an approved species off of the attached Street Tree List. 79 Matt Baker of the City's Street Oversizing Department asked that the applicant please show proposed improvements (sidewalk, curbline, etc.) to the South College Avenue Frontage Road. Please contact Matt, at 224-6108, if you have a question about his comment. Page 1