HomeMy WebLinkAboutSIDEHILL, FILING ONE - PDP - 32-01B - CORRESPONDENCE - MEETING COMMUNICATIONLight & Power -Monica Moore
• Stormwater pipe on Strawfork Drive is less than 5' away from electric lines. Need minimum of
5' clear from outside of pipe.
Electric & gas service meter locations on multifamily buildings needs to be pinned down.
Minimum of 3' separation between electric and gas meters. Detail to be provided of meter
location and layout on building.
Electric meters need to be on the electric stub side and electric meters shall not be placed at
same location as window wells.
• On single family units James Company prefers electric meter on house side and gas meter on
garage side of unit.
Water/Wastewater-Jeff Hill
• Randall confirmed with everyone in attendance that Water/Wastewater has no problems with
sanitary sewer services being underneath driveways.
• If sanitary service is under driveway then driveway location must be dedicated by an access
easement on plat.
• As a rule of thumb Water/Wastewater prefers sanitary service to be either north or east of water
service. Due to tree/utility service separation problems Eldon asked if we could bend that rule
and just have sanitary 10' either side of water service with sanitary being underneath driveway
always. This will allow for plenty of separation between trees and services in all instances. Jeff
to check with Roger Buffington.
• Water service to be on centerline of lot.
• Water services will not be allowed under driveway and shall maintain a minimum distance of 3
feet from driveway.
• Water service must come into front of house, no service allowed to be on the side.
• The City prefers no water mains in alleys.
• Services to lots on Filing Two will not be shown at this time. James Company, Cityscape and
JR Engineering will try to pin down lot layout and then provide a revision to Filing One utility
plans prior to commencement of construction.
AT&T -Dennis Greenwalt
• Cable and Phone to be serviced from the rear of lots. Will need side yard easements on various
lots to reach rear.
Xcel Energy -Connie Woodard
• Power poles on north side of Drake Road will need to be undergrounded at developer's
exspense.
• Connie was not sure if 15' utility easement was enough room to accommodate electric and gas.
She will check with Len Hilderbrand and confirm. She will give Jon L. a call when confirmed.
(Followup: Connie called 1-30-03 and confirmed that 15' will be enough room.)
Jon Lofton of JR Engineering has prepared the preceding for documenting our recent meeting. Further
additions, clarifications, and amendments to any of the items contained herein are invited. Please direct
comments promptly to the writer so that the meeting minutes can be amended accordingly.
Copies: All in attendance
�AWJ)
Date of Meeting: January 29, 2003 Re: Johnson Property
2:30 PM
Location: City of Fort Collins Issue Date: February 3, 2003
Engineering
Subject: Utility Coordination Meeting
Submitted By: Jon Lofton
In Attendance: Susan Joy, City of Fort Collins
Troy Jones, City of Fort Collins
Jeff Hill, City of Fort Collins
Monica Moore, City of Fort Collins
Wes Lamarque, City of Fort Collins
Lou Cordova, City of Fort Collins
Tim Buchanan, City of Fort Collins
Dennis Greenwalt, AT&T Broadband
Connie Woodard, Xcel Energy
Merle Bush, James Company
Eldon Ward, Cityscape Urban Design
Joe Carter, Cityscape Urban Design
Randall Provencio, JR Engineering
Jon Lofton, JR Engineering
ITEMS DISCUSSED
En ing eering-Susan Joy
• There was much discussion about the need for a dedicated right turn lane from west bound
Drake onto north bound Timberline. Jon will check to see if ultimate plans for
Timberline/Drake intersection accounted for a right turn lane. (Followup: Plans for
Timberline/Drake show no dedicated right turn lane from Drake onto Timberline. I called Matt
Baker (Street Oversizing) to find out the reasoning on the intersection layout. Matt said that the
traffic study did not warrant a right turn lane at that location. East Drake is a two lane arterial
and west Drake is a four lane arterial. It made more sense to transition from the two to four lane
arterial on the east side of the intersection rather than the west side. The two through lanes are
not required on the east side of Drake but were put there for transition purposes. We could
possibly restripe one of the lanes to be a through/right or have a dedicated right turn with one
through lane. Susan Joy will bring up subject at next Transportation Coordination meeting on
Thursday Feb. 6 and will call JR Engineering immediately afterwards with the decision that was
made.)
Planning & Zoning Troy Jones
0 Trees along street may be counted per block and not necessarily one tree per lot.