HomeMy WebLinkAboutSWIFT ADDITION TO FOSSIL LAKE P.U.D. - COUNTY REFERRAL - 33-01(I) - CORRESPONDENCE - (5)Management Area. The whole intent of the Resource Management Area is to provide an
area for wildlife undisturbed from human activity. Have the applicant talk to Doug
Moore about this issue. A substantial fence that is extremely difficult (or impossible)
for a person to cross needs to be located between tract H and the Resource Recovery
Area with this proposed configuration. It would help if tract H was designed in such a
way that a solid row of lots were provided in a configuration that wouldn't physically give
any opportunities for pedestrians to get into the tract.
11. Park Planning - Show the trail on the site plan.
12. Park Planning - When the trail approaches Lake Ranch Road from the west, it should not
cross at mid block, but rather cross at the intersection of Shallow Pond Drive and Lake
Ranch Road. Otherwise if the trail goes through the open space tracts along the
western edge of the property, the design looks fine. See the purple line on the redlined
plans.
13. Please see the attached comment sheets from Traffic Operations, Engineering, and
Transportation Planning.
14. I have not received any comments from 5tormwater or Natural Resources. If and when
I do, I'll forward them on. I recommend that the applicant call Basil Hamdan and Doug
Moore directly to discuss.
I forwarded the redlines directly to the applicant. If you have any questions regarding
these comments, please contact me or any of the departments listed above.
nce�elyl,
tl,�
cc: - Applicant
File
4
the two stubs at the southeast corner of the project can be eliminated.
Otherwise, the connections must remain.
7. Current/Advance Planning - Fossil Creek Reservoir Sub -area Supplemental Regulations
I.F.5.a.(2) states that "if any block face is over 700 feet long, then walkways connecting
to other streets shall be provided at approximately mid -block or at intervals of at least
every 650 feet, whichever is less." The northern block face of Green Spring Drive is
required to have an additional mid -block pedestrian connection to satisfy this
requirement. It looks like the most appropriate location for this would be along the
west side of lot 8, connecting all the way down to Shallow Pond Drive.
8. Current/Advance Planning - Fossil Creek Reservoir Sub -area Supplemental Regulations
I.F.4.f. requires that 90% of the dwellings in this project be located within a maximum
of one-third mile of a one acre public or privately owned park. Such park must meet the
design criteria required in I.F.4.f (1)-(5). The most recent approved preliminary
layout shows a 1.6 acre park at the northeast corner of Lake Ranch Road and
Shallow Pond Drive. This park is necessary in order to satisfy this standard, and
must not be removed. It does not appear that the neighborhood center west of this
site has any component that would satisfy this "small neighborhood park" criteria
specified in I.F.4.f (1), which states the following: "Location. Such parks shall be highly
visible, secure settings formed by the street layout and pattern of lots and easily
observed from streets. Rear facades and rear yards of dwellings shall not abut more
than two (2) sides or more than fifty (50) percent of the perimeter frontage of the
park." The neighborhood center's garden area to the southeast of the pool complex is
not formed by the street layout, is not easily observed from streets, and is abutted by
rear facades and rear yards on more than 2 sides and more than 50% of the perimeter
frontage of the park. If my memory serves me correct, there is an area across the
street to the west of the neighborhood center in the Fossil Lake PUD that may possibly
qualify as this small neighborhood park. If so, it still does not satisfy this requirement
for the Swift Addition because this park is too far away to satisfy the requirement
that 90% of the units be within a third of a mile from the "small neighborhood park."
9. Current/Advance Planning -For clarification, the Fort Collins Land Use Code defines
"lot width" as follows: "Lot width shall mean the horizontal (plan view) distance between
the side lot lines as measured along a straight line parallel to the front lot line or the
chord thereof. The minimum lot width shall be measured between the side lot lines
along a line that is parallel to the front lot line and located at the minimum front
setback distance from the front lot line. In the case of cul-de-sac lots, the minimum lot
width may be measured between the side lot lines along a line that is parallel to the
front lot line and located at the actual front building line." Please use this definition
when reviewing the minimum lot width of 100 feet that is required in the Urban Estate
Area. On wedge shaped lots, this will require the building to be set back quite a ways
from the street.
10. Current/Advance Planning - The configuration of Tract H seems to encourage
pedestrian access between the backs of the residential lots and the Resource
3
4. Current/Advance Planning - Fossil Creek Reservoir Sub -area Supplemental Regulations
II.B.2 requires that "the local street system shall provide multiple direct connections to
and between local destinations such as parks, schools, shopping." The approved
Preliminary PUD has a configuration of it's local street system in a manner that does in
fact have streets and blocks that provide multiple direct connections between the lots
in the neighborhood and the two streets that connect to the north of the site, where
the future school and public park sites. These connections (from the approved
Preliminary PUD) qualify as direct connections as a result of a grid -like network of
streets that channel traffic toward either of the two connections. The grid street
pattern typifies the ideal system of directness where one can go north or south, east or
west to easily get to one's destination. The problem we see with curvilinear residential
configurations with a predominance of cul-de-sacs is that the local street connections
are forced to follow a circuitous route, which is the opposite of directness. The
proposed new configuration of Green Spring Drive and North Shore Lane changes the
approved grid -like nature of the layout so that the local street network provides a
circuitous connection rather than the required direct connection between the lots in
the neighborhood and the two streets that connect to the future school and park north
of the site. Such a deviation of the requirements would require either a Modification of
Standards in accordance with the process spelled out in Section 4.2.1.1-1 of the Larimer
County Land Use Code or Alternative Compliance as specified in the Fossil Creek
Reservoir Sub -area Supplemental Regulations II.B.8.
5. Current/Advance Planning - Fossil Creek Reservoir Sub -area Supplemental Regulations
II.B.2 goes on to state the following: "Local streets must provide for both intra- and
inter -neighborhood connections to knit developments together, rather than forming
barriers between them. The street configuration within each parcel must contribute to
the street system of the neighborhood." The proposed new configuration does not
provide adequate intra-neighborhood connections that allow the neighborhood to
knit together,, but rather proposes a local street system that forms barriers in the
connectivity within the neighborhood itself. The cul-de-sac at the southern end of
Green Spring Drive unnecessarily dead -ends when it could easily be connected with
Rocky Stream Drive, therefore creating an unnecessary barrier to the connectivity of
the local street network within the neighborhood. The design of the two cul-de-sacs
that are part of Southview Court limit the street connectivity of lots 3 thru 18 to one
point of connection with the remainder of the neighborhood, thereby creating another
unnecessary barrier rather than the required intra-neighborhood local street
connections. We would like to reiterate that the approved Preliminary PUD is fine with
regard to this standard, however the proposed reconfiguration of the PUD does not
satisfy the standards. Such a deviation of the requirements would require either a
Modification of Standards in accordance with the process spelled out in Section 4.2.1.1-1
of the Larimer County Land Use Code or Alternative Compliance as specified in the
Fossil Creek Reservoir Sub -area Supplemental Regulations II.B.8.
6. Current/Advance Planning - If the land to the east and south of this property gets
restricted from development through the provision of a conservation easement, then
F1
COmmc y Planning and Environmental
Current Planning
City of Fort Collins
September 28, 2001
Matt Lafferty
Lorimer County Planning Department
P.O. Box 1190
Fort Collins, CO 80522-90
-vices
City staff has reviewed the proposed changes to the approved preliminary layout of the
Fossil Lake P.U.D. - Swift Addition that has been informally submitted by the applicant
for comment, and we offer the following comments.
DEPARTMENTAL CONTACTS:
Current Planning -
Advance Planning -
Engineering Department-
5tormwater Utilities -
Natural Resources Development Planner
Transportation Planning
Traffic Engineering
COMMENTS:
Troy Jones
221-6750
Pete Wray
221-6376
Sheri Womhoff
221-6605
Basil Hamden
221-6681
Doug Moore
221-6750
Tom Reiff
416-2040
Ward Stanford
221-6820
Current/Advance Planning - We strongly feel that the proposed change in the
configuration to the approved Preliminary Fossil Lake PUD - Swift Addition is a
substantial change to the approved plans and should be treated as a new project
with full review and a full schedule of hearings. We feel the new configuration does
not meet the Fossil Creek Reservoir Sub -area Supplemental Regulations in several
fundamental ways, and therefore needs revisions bringing it up to standards or
Alternative Compliance requests and/or Modifications to the standards. We would like
to reiterate that this project will be annexed very soon after approval, so we feel very
strongly that our interpretations of the language in the Fossil Creek Sub -area
Supplemental Regulations be enforced during the review of this project.
2. Current/Advance Planning Please clarify where the trails and pedestrian paths are on
the site plan.
3. Current/Advance Planning - Fossil Creek Reservoir Sub -area Supplemental Regulations
II.B.1 defines "local street system" as "the interconnected system of collector,
connector, and local streets providing access to development from an arterial street."
This term is used in many of the following comments.
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020