HomeMy WebLinkAboutRIGDEN FARM, THE COLONY - PDP - 56-98AC - CORRESPONDENCE - (5)If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at (970)221-6341.
Yours Truly,
Steve Olt
City Planner
cc: Marc Virata
Reno Cappelli
Current Planning File #56-98AC
Page 9
'Water/Wastewater:
The 2 service stubs at the northeast corner of the property need to be
abandoned.
2. Abandonment of some easements and right-of-way is necessary.
Transportation Planning:
1. Transportation Planning likes the mid -block crossing. Has Eric Bracke of
Traffic Operations been contacted to see if it is OK with him?
Current Planning:
1. The parking lot screening, along Custer Drive and to the properties to the
east and south, is insufficient. Additional tree and shrub plantings are
needed.
2. The building foundation plantings are weak.
This completes staff (and outside reviewing agencies) review and comments at this
time. Some additional red -lined plans from the Current Planning Department are
included with this comment letter. Another round of formal staff review is not
necessary;'however, the issues expressed in this letter must be addressed prior to a
public hearing being scheduled. Please submit all necessary documents to the
Current Planning Department and they will be distributed to the appropriate
departments and agencies. This proposal is subject to the 90-day revision re -
submittal requirement (from the date of this comment letter, being July 25, 2005)
as set forth in Section 2.2.11(A) of the Land Use Code. Be sure and return all red -
lined plans when you re -submit. The number of copies of each document to re-
submit is shown on the attached Revisions Routing Sheet.
Page 8
Number: 45 Created: 7/13/2005
[7/13/05] The existing water and sanitary sewer main stubs located at the
north east corner of this site must be used or abandoned in Custer drive.
Provide all information necessary for the abandonment (i.e., remove pipe from
manhole, Fill opening in manhole, etc.).
Number: 46 Created: 7/13/2005
[7/13/05] See site, landscape and utility plans for other comments.
Additional comments from City staff and outside reviewing agencies:
Light & Power:
1. Light & Power will install the lighting on Kansas Drive. There are
requirements for separations between light poles and street trees.
2. Please coordinate the transformer locations with Light & Power.
3. Please show electric facilities on the utility and Landscape Plans.
4. Please coordinate the meter locations with Light & Power.
Engineering:
Has a revised variance request letter been submitted to the City for review?
2. The applicant needs to document the ADT's for the driveways.
3. How is Kansas Drive to be dedicated?
Stormwater:
1. How is the storm water from the parking lots going to get to the inlet?
Page 7
Topic: Plot
Number: 51 Created: 7/15/2005
[7/15/05] Call out the existing drainage easement along the west property line.
Please place the inlets and rundown area at the east parking lot within a
drainage easement.
Topic: Utility Plans
Number: 49 Created: 7/15/2005
[7/15/05] Provide pans for the run downs from the parking lot curb cuts to the
inlet locations.
Department: Transportation Planning Issue Contact: David Averill
Topic: 6enerol
Number: 39
[7/12/05] Previous comments addressed.
Department: Water Wastewater
Topic: General
Number: 6
Created: 7/12/2005
Issue Contact: Jeff Hill
Created:4/4/2005
[7/13/051
[4/4/05] Final Comments- Label sizes of fire lines, show and label the
tees/G.V.s on the fire lines, label lengths of water mains between fitting, label
curb stops and meter pits, Provide profiles of sanitary sewer mains, include a
general note to core drill all openings into existing manhole and reshape bench.
Number: 42
Created:7/13/2005
[7/13/05] Clearly define all aspects of water and sanitary sewer line
construction (i.e. Distances, diameter, fittings, thrust blocks, etc.).
Number: 43
Created:7/13/2005
[7/13/05] Will the proposed sanitary sewer service for lot one be in conflict
with the proposed 8-inch water main? If the sanitary sewer service crosses
above or within 18-inches vertically of the proposed water main, then provide
concrete encasement 10 feet each way at the water main crossing.
Page 6
Number: 4 Created: 3/18/2005
[7/11/05] Transformer location has yet to be coordinated with Light and
Power. The transformer cannot be located within the City's right-of-way.
Proposed utilities must be shown on utility plans.
[3/18/05] Coordinate transformer location(s) and meter locations with Light
and Power. Transformers can be located no more than loft from a paved
surface that can be accessed by City trucks and equipment.
Department: Police Issue Contact: Joseph Gerdom
Topic: 6enerol
Number: 47 Created: 7/13/2005
[7/13/05] Majority of both parking lots/drives are under the required 1.0fc.
Plant materials are shown on photometric blocking fire sprinkler room door.
Would recommend low plant materials in front of ground floor windows (less
than 24" mature height).
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Drainage
Number: 40 Created: 7/12/2005
[7/12/05] Please clarify how flows from the parking lot will enter the pipe on
the east and west sides, more detail is needed at final.
Topic: Erosion Control
Number: 50
[7/15/05]
At final provide security deposit
Topic: Landscaping
Created:7/15/2005
and efficiency calculations.
Number: 48 Created: 7/15/2005
[7/15/05] Show and identify any landscaping that will be placed on this site to
satisfy the buffering requirement of the Brooklyn Row Housing development to
the west.
Topic: Overflow
Number: 41 Created: 7/12/2005
[7/12/05] Make sure that any landscaping that is placed within the overflow
area will not block the drainage.
Page 5
Number: 44 Created: 7/13/2005
[7/13/051 The plans indicate that the realigned Kansas Drive is to be
dedicated by separate document, yet there is a plat for the development which
can convey right-of-way. The plat does not indicate that right-of-way is to be
dedicated although it is dimensioned out. Please clarify.
Topic: Landscaping
Number: 52 Created: 7/15/2005
[7/15/05] Please ensure that the landscaping installed within the site distance
easement meets the requirements of the restrictions within the site distance
easement. Colorado Blue Spruce is definitely not allowed within the easement.
Department: Light & Power Issue Contact: Monica Moore
Topic: General
Number: 3 Created: 3/18/2005
[7/11/05] Proposed Streetlights must be shown on both utility plans and
Landscape plans.
[3/18/05] Street trees along Kansas Drive must maintain minimum clearances
to streetlights (40ft. For shade trees and 15ft for ornamental trees). Contact
Light and Power to initiate streetlight design.
Number: 38 Created: 7/11/2005
[7/11/05] Light and Power will provide and install street lighting along Kansas
Drive. The Site Photometric Plan shows private lighting in the City right-of-
way. Private lighting CANNOT be installed along public streets within the
City's right-of-way.
Topic: Utility Plans
Number: 2
Created: 3/18/2005
[7/11/05]
(3/18/05] Show existing electric facilities on overall utility plan. Any
relocation of existing facilities will be at developer's expense.
Page 4
Topic: Genera/
Number: 12 Created: 4/5/2005
[7/12/05] The response letter indicates this was resolved. A revised variance
request was not received and is required.
[4/5/05] The variance request letter attempts to justify the variance for the
alignment offset on Kansas partially based upon a rationale that the geometry
of a non -offset Kansas Drive alignment creates a hardship in developing the
property and that meeting City criteria for horizontal alignment would make the
parcel practically undevelopable. I cannot agree with this rationale. The
particular product type proposed by the development may make meeting design
criteria difficult, but a different product type could allow for the road to
connect without an offset. The previous development proposal on the project
(Posto Bella), in fact, met City requirements and did not result in an offset in
the design of Kansas Drive. Defining a situation as hardship cannot be used if
only for one specific product type. While the City's Traffic Engineer has
indicated that he likely would accept the offset in Kansas Drive, the variance
request needs to amended to reword or eliminate the "hardship" argument.
Number: 14 Created: 4/5/2005
[7/12/05] The response letter indicates that the driveway setback is
acceptable as shown. My recollection is that the information discussed over the
phone with the consultant would have it appear that a variance request would
not be needed, however the consultant should provide traffic count information
as part of the record to demonstrate that the criteria is being met.
[4/5/05] The distance from the flowline of Kansas Drive to the first parking
stall on each driveway is 20'. Please provide traffic volume information for
Kansas Drive and each parking lot to verify that the appropriate criteria in
LCUA55 Figure 19-6 is being met.
Number: 25 . Created: 4/5/2005
[7/12/05] Carried over as not being resolved.
[4/5/05] Add a note for the patching shown on the construction plan set that:
"Limits of street repair are approximate. Final limits to be determined in the
field by the City Engineering Inspector at the time the street cuts are made."
Page 3
Number: 57 Created: 7/25/2005
[7/25/05] Section 3.2.1 (D)(3) of the Land Use Code sets forth Minimum
Species Diversity requirements for trees. Several of the proposed trees do not
satisfy this requirement (see red -lined Landscape Plan).
Topic: Plot
Number: 54
Created:7/25/2005
[7/25/05] The Technical Services Department offered the following
comments:
a. The legal description closes but the plat does not match the legal
description.
b. The Point of Beginning needs to be labeled.
c. The Basis of Bearings Statement in the legal description does not match
Note #1.
d. The subtitle of the plat needs to say "Being a Replat of ..... ".
e. This is a preliminary review. Please re -submit for a more thorough review.
f. What is the 51' wide strip north - south across the plat?
Department: Engineering Issue Contact: Marc Virato
Topic: Construction Plans
Number: 11 Created: 4/5/2005
[7/12/05] This does not appear to have been addressed, as the curb return
radii for the Kansas/Custer intersection is not indicated.
[4/5/05] Please indicate the curb return radii for the street intersections and
driveway intersections with streets on the construction plan set.
Number: 27 Created: 4/5/2005
[7/13/05] The existing grade was not indicated on the plans.
[4/5/05] On sheet 7 of the construction plans, please show more of the
existing centerline (and label the grade) along Kansas Drive south of the site to
verify how the preliminary design ties into the existing roadway.
Page 2
STAFF PROJECT REVIEW
Cityof Fori Collins
JR Engineering Date: 07/25/2005
c/o Lee Watkins
2620 East Prospect Road, #190
Fort Collins, CO 80525
Staff has reviewed your submittal for RIGDEN FARM, 12TH FILING, THE
COLONY - PDP - TYPE I, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: General
Number: 53 Created: 7/19/2005
[7/19/05] Carl Jenkins of the Post Office indicated that for mail service,
centralized delivery of a minimum of 3 centralized box units (CBU, industry
type III) are required. Please revise the plan to show the required CBU
locations as approved by the U.S. Postal Service. In all cases the CBU's must be
located in the public right-of-way or a designated easement. Be advised that
the responsibility of purchase and maintaining the CBU's, with concrete pads, is
that of the owner/developer/builder/HOA. Prior to occupancy within the
development approved mail receptacles must be in place. A Delivery Agreement
must be in place prior to any delivery of mail. Please contact Carl Jenkins,
Growth Coordinator, U.S. Postal Service, 301 East Boardwalk Drive, Fort Collins,
CO. Phone #970-225-4130, cell #970-214-3668, fax #970-225-4139.
Number: 55 Created: 7/25/2005
[7/25/05] Please see Current Planning's red -lined plans that are dated
6/14/05. There are many comments made on the previous Site and Landscape
Plans dated 2/15/05 & 3/2/05 that have not been addressed with the current
re -submittal. Many are repeat, unchanged comments.
Topic: Landscaping
Number: 56 Created: 7/25/2005
[7/25/05] The parking lot and driveway tree and screening standards set forth
in Section 3.2.1(E)(4) of the Land Use Code are still not being met with the
revised Landscape Plan.
Page 1