HomeMy WebLinkAboutFOSSIL LAKE PDP, 4TH FILING - PDP - 33-01G - CORRESPONDENCE - (7)Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
Number: 86 Created: 11 /4/2002
4/8/04
Please provide concrete reinforcement detail for water quality outlet structure.
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Grading Plans
Number: 99 Created: 4/8/2003
Please call out pipe invert elevations and top of grate elevation on grading plan.
Topic: Storm Line
Number: 97 Created: 4/8/2003
Please check with Light and Power for the alignment of storm line 2. It is currently running behind the
walk which is normally where Light and Power run their lines.
Topic: Storm sewer profiles
Number: 100 Created: 4/8/2003
Please call out 100 year HGL elevations on all storm sewer profiles.
Topic: Utility Plans
Number: 98
Created: 4/8/2003
Please call out size and type for all storm sewers and inlets on overall utility plans.
Department: Transportation Planning Issue Contact: Tom Reiff
Topic: General
Number: 96 Created: 3/28/2003
The newly proposed street (Fossil Lake Place) needs to be constructed with directional access ramps
at the Dripping Rock Lane and Ziegler intersections (see red lines). A new ramp on the west side of
Ziegler will also need to be constructed that aligns with the ramp on the east side and connects to the
sidewalk proposed with the county development to the west. This will then satisfy the pedestrian LOS
to the future community park.
Department: Water Wastewater Issue Contact: Terry Ferril
Topic: General
Number: 103 Created: 4/9/2003
Fort Collins - Loveland Water District and the South Fort Collins Sanitation District have reviewed the
above mentioned project and have no objections or comments.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project, please
feel free to c I meat (970) 221-6750.
ours ruly,
j
Tro s
ty PI nner
Page 3
Number: 90 Created: 11 /6/2002
[10/30/02] A minimum of 2 feet of cover above a pipe to the scarified subgrade needs to be provided.
Do not appear to be meeting this for Storm 2. 03/31/03 Repeat The minimum cover requirements are
not being met for the 24 inch storm sewer pipe. Need to look at using two pipes, squashed pipe or
changing hose ht system works. Need to meet the minimum cover requirements. The use of geogrid
does not solve this problem.
Number: 107 Created: 4/9/2003
General notes - need to note the variances approved in note 48.
Number: 108 Created: 4/9/2003
A variance was granted to use non directional ramps at Shallow Pond and Dripping Rock Lane, as it
would match what was across the street. This is not granted for the other intersections; provide
directional ramps at the intersection of Dripping Rock and Fossil Lake Place and Dripping Rock Lane
and Ziegler Road. Both of these T intersections shall have ramps on 3 legs.
Number: 109 Created: 4/9/2003
Need to show the steps in the sidewalks on the site and landscape plans.
The steps can not be in any sidewalk connection from a unit that is to be handicap accessible.
Number: 110 Created: 4/9/2003
Need to provide additional elevations at the sw driveway intersection.
Number: 111 Created: 4/9/2003
The plan and profile sheets indicate that a 4 foot pan is to be used, but in accordance with detail 7-30
it would be a 6 foot pan. Please adjust.
Number: 112 Created: 4/9/2003
At the north end of the street - if the improvements are not to be constructed to the property line then
money will need to be provided prior to the issuance of the first building permit for the portion not to
be constructed. Also it looks like there might be a spot that would hold water in the area beyond the
pavement, but since the utilities will be installed in this area and the ground will be disturbed for that
the grading can probably be done such that that doesn't happen.
Number: 113 Created: 4/9/2003
Don't meet the minimum vc lengths for the curves closest to Ziegler rd. Request a variance and I will
approve it.
Number: 114 Created: 4/9/2003
Remove Detail 16-6F this is not needed with the truncated domes. Need to add the truncated dome
detail, use either the CDOT or Greeley detail. Note that this detail is just for the dimensions and
texture of the colored area of the ramp.
Department: Excel Energy Issue Contact: Len Hilderbrand
Topic: General
Number: 104 Created: 4/9/2003
No Problems.
Number: 105 Created: 4/9/2003
Meter locations will need to be coordinated closely with PSCO to ensure clearance requirements.
Number: 106 Created: 4/9/2003
Contact Connie Woodard 225-7843 to schedule estimates and installation.
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
� E
ALLER LINGLE ARCHITECTS P.C. Date: 04/09/2003
BRAD MASSEY
712 WHALERS WAY, #B-100
FT. COLLINS, CO 80525
Staff has reviewed your submittal for FOSSIL LAKE PDP - 4TH FILING - TYPE I (LUC), and we offer
the following comments:
ISSUES:
Department: Current Planning Issue Contact: Troy Jones
Topic: General
Number: 70 Created: 9/5/2002
[4/8/03] There's a balance that needs to be achieved between having enough light for safety [LUC
3.2.4(C)], and having an unobtrusive degree of brightness [LUC 3.2.4(D)(3)&(5)]. If available, use
smoked glass type for the Progress Lighting P548231 fixture. The Manor House 77611 fixture should
be toned down from 175 watts to 70 watts, used smoked glass, and use any available refractor or
louvered reflector that will direct the light downward.
[1117102] Repeat Comment. As soon as the lighting plan is submitted, I'll comment on it. Joe
Gerdom from the Police Department will also comment. Submit 3 copies when it's ready. Make sure
it satisfies the standards in 3.2.4 of the LUC.
[915102] Lighting Plan needs to include specifications of the poles, pole fixtures, and wall mounted
fixtures. Section 3.2.4(D)(3) of the LUC requires that fixtures be fully shielded and shall feature sharp
cut-off capability so as to minimuze up -light, spill -light, glare and unnecessary diffusion on adjacent
property. The specs are necessary to determine compliance with this standard.
Number: 101 Created: 4/9/2003
The site plan must be labeled in the lower right hand corner as sheet 1 of 5, the lansdscape plan as
sheet 2 of 5, and the building elevations as sheets 3, 4, and 5 of 5.
Number: 102 Created: 4/9/2003
There are 141 trees proposed on the landscape plan. Section 3.2.1(D)(3) of the LUC requires that no
more than 15% of those are a single species. This means that no more than 21 trees can be a single
species. There are 27 Pinyon Pine's proposed. Please revise the proposed quantities of the various
trees so that no more than 21 of a single species are used.
Number: 115 Created: 4/9/2003
As soon as we receive the letter of intent for the off -site easement refered to in comment # 26, we are
ready to schedule the public hearing. I'd like to tentatively shoot for May 1, 2003 at 5:30 p.m. Does
this work for you? We will need the letter of intent by April 16, 2003 in order to be able to make the
May 1 st date work. We are required to mail notice of the hearing at least 2 weeks prior to the
hearing.
Department: Engineering Issue Contact: Sheri Wamhoff
Topic: General
Number: 26 Created: 9/3/2002
Will need a letter of intent for the off -site easements before this item can be scheduled for a hearing.
03/31 /03 Repeat Need the off -site easement for the utilities beyond the property line to the north.
The easement or a signed letter of intent from the property owner granting the easement is needed
prior to scheduling the project for hearing.
Number: 88 Created: 11 /6/2002
[10/30/02] Identify the type of sleeve to be used to sleeve the irrigation line. 3/31/03 The irrigation line
under the roadway needs to be sleeved. It was previously noted that way, but is no longer noted.
Page 1