HomeMy WebLinkAboutSEVEN OAKS ACADEMY'S LITTLE ACORNS - FDP - 48-01A - CORRESPONDENCE -Department: Zoning Issue Contact: Jenny Nuckols Topic: General 12 Label building envelope, dimensions and footprint, covered entrys should be included. 14 Show back-up distance in new parking lot area 18 Note the distance between the new building and the existing 23 Is there a sidewalk along the private drive. Check with eng for their standards. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, TED SHEPARD City Planner Page 3 General This facility shall comply with PFA Administrative Policy 86-13 for Day Care Facilities. Contact Ron Gonzales for a copy. 49 FIRE PROTECTION The building exceeds 5000 square feet, and shall be fire contained or fire sprinklered. Utility plans indicate a fire sprinkler system is to be installed. Topic: utility plan 43 WATER SUPPLY A hydrant is required within 300 feet of structure and shall deliver 1500 gpm @ 20 psi. Department: Police Topic: Site and Landscape 50 Lighting plan not clear on illumination at entrances. Department: Stormwater Utility Topic: Drainage Report 75 Please provide copies of Exhibit 4A in the report. Issue Contact: Joseph Gerdom Issue Contact: Basil Harridan Please submit two additional signed and stamped copies of the report for approval. Topic: Easements 69 Please provide copies of the drainage easements that are to be dedicated by separate document for all detention ponding areas. Topic: Utility Plans 74 Please show a side view of the proposed outlet box, as delineated on the reclined utility plans. Please address all comments on the reclined utility plans. Since these comments are of minor importance, we are now ready for mylars. Department: Transportation Planning Issue Contact: Tom Reiff Topic: Site and Landscape 24 (Repeat comment 3-5-02) Install a 5 foot attached walkway along the eastern edge of the property parallel to the private drive and connects to the sideway in front of the southern parking spaces (see site plan red lines). The sidewalk is necessary to provide pedestrian connectivity internal to all uses within the center and to provide safe access to businesses from surrounding residences. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General 71 No Comments Ready for Mylars Page 2 STAFF PROJECT REVIEW City of Fort Collins V.F. RIPLEY ASSOC. Date: 4/5/2002 CATHY MATHIS 401 W. MOUNTAIN AVE. #201 FT. COLLINS, CO 80521 Staff has reviewed your submittal for SEVEN OAKS ACADEMY'S LITLE ACORNS PDP/FC #48-01/48-01 A, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Sheri Wamhoff Topic: General 66 please submit copies of the drainage easements that need to be dedicated by separate document. These will need to be received in final format with filing fees prior to acceptance of the mylars for signature by the City. 72 Add to the legend on sheet 6 that the diagonally hatched areas are' areas where easements are to be provided by separate document' or some language to that effect. 73 Sheet 4, 5, 6, 7, 9. Remove building envelope label. The plat does not define the area outside of the easements as the building envelope. In fact there are no notes on the plat regarding the building envelope or its boundaries. Department: PFA Issue Contact: Ron,Gonzales Topic: General 44 ADDRESS The address is required to be visible from the street fronting the building, with minimum 6 inch numerals on a contrasting background. 45 FIRE ALARM SYSTEM A complete fire alarm system is required to be installed in accordance with NFPA 72, Fire Alarm Code. 46 KNOX BOX A knox box key box is required to be located at the front door. 47 KITCHEN FIRE PROTECTION A hood/duct fire protection system may be required in the kitchen Page 1