Loading...
HomeMy WebLinkAboutSEVEN OAKS ACADEMY'S LITTLE ACORNS - PDP - 48-01 - CORRESPONDENCE -7. Please indicate by which measurement the P.D.P. exceeds the minimum required amount of parking. Is it the two per three employees or one space per 1,000 square feet of building. 8. There is a sight distance easement dedicated on the existing plat. This easement should be shown on the Landscape Plan. Also, Public Service/Excel indicates that there is a gas line located in the eight foot easement on the south side of Richmond Drive. This should also be shown on the Landscape Plan. Please indicate that these existing constraints preclude the uniform spacing of street trees along Richmond. 9. Please add two street trees along the east side of the building. These trees are needed to comply with Section 3.2. 1 (D)(1)(c) - fidl tree stocking. 10. Be sure to indicate the exact species, size and quantities of shrubs along Richmond Drive and other shrub beds. Along Richmond, it would be consistent to match the plantings installed with the first building. 11. Please revise the Landscape Plan to indicate that the scale is actually 1" = 20', not 1" = 30'. 12. On the architectural sheet, please indicate under "Notes" that exterior materials are intended to match the existing building. 13. Please indicate the surface material of the play area. 14. On the Lighting Plan, the written description of the light fixture did not reproduce and is unreadable. 15. Staff recommends a Minor Amendment be submitted for the existing building (Lot 3A), after Final Compliance for the P.D.P. (Lot 3B). As always, please call if you have any questions or concerns about these comments, or to set up a meeting with the appropriate Staff. Sincerely: Ted Shepard Chief Planner I Comm. .y Planning and Environmental, .vices Current Planning January 24, 2002 Mrs. Cathy Mathis V-F Ripley and Associates 401 West Mountain Avenue Fort Collins, CO 80521 Dear Cathy: Staff has reviewed the request for Seven Oaks Academy's Little Acorns P.D.P. and offers the following comments: See attached comments and redlines from Engineering, Stormwater, Water&Wastewater. 2. A Modification of Standard will be required because of the difficulty in complying with the "build -to line" standard. This is Section 3.5.3(B)(2)(b) — Orientation to Build -to Lines for Streetfront Buildings - which requires the building to be no more than 15 feet from the Richmond Drive right-of-way. Because Staff agrees that it is desirable to maintain a consistent relationship with the existing building along Richmond Drive, we will support such a Modification of Standard request. The request should include written and graphic materials that explain how the proposed building orientation promotes the purpose of the standard. 3. Staff recommends that a four -foot wide attached sidewalk be installed along the east side of the property, along the private drive, that would connect to the six parking spaces on the south. This walk would allow the P.D.P. to comply with Section 3.2.2(C)(6) — Walkways — and help tie the building to the convenience store. 4. Please provide parking lot dimensions, including aisle width, stall length and width. Be sure that the stalls are no less than 17 feet in length. 5. Please verify with Stormwater that the raised crosswalk will not block storm flows. If so, then a sidewalk chase may needed. Also, be sure to label the width of the crosswalk on the Site Plan. 6. Please indicate on the Site Plan the locations, if any, of the Transfort bus stops. ?8l North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020 6 Is a 6-inch fire line required? 7 Provide stationing of sanitary sewer service from the downstream manhole. Provide inverts of existing manholes in the adjacent vicinity. 8 Provide the following standard details with the next submittal: Sewer bedding, Sewer service, Thrust block, Meter pit. Department: Zoning Issue Contact: Jenny Nuckols Topic: General 11 Please remove topo lines from final site plan 12 Label building envelope, dimensions and footprint, covered entrys should be included. 13 Note the distance to property lines 14 Show back-up distance in new parking lot area 15 All parking spaces are being shown as compact. This isn't considered a long-term parking lot as most cars will be used for dropping off/ picking up of kids. 3.2.2(L) 16 New trash enclosure needs to be gated, Please make large enough to also hold recyclables 17 Show handicap stall dimensions on site plan. 18 Note the distance between the new building and the existing 19 Need to show street trees along the private drive and along Richmond Dr. 3.2.1(E)(4) 20 See section 3.2. 1 (E)(4)(b) regarding parking lot screening 21 Review fill -tree -stocking section 3.2. 1 (D)(1)(c). This may not meet those requirements. 22 On landscape plan, need to see the shrub bed area in reater detail. Call -out whats going to be planted and how many etc... 23 Is there a sidewalk along the private drive. Check with eng for their standards. Page 2 i-1 6aSTAFF PROJECT REVIEW City of Fort Collins V.F. RIPLEY ASSOC. Date: 1/22/2002 CATHY MATHIS 401 W. MOUNTAIN AVE. #201 FT. COLLINS, CO 80521 Staff has reviewed your submittal for SEVEN OAKS ACADEMY'S LITLE ACORNS PDP - TYPE I (LUC), and we offer the following comments: ISSUES: Department: Light & Power Issue Contact: Doug Martine Topic: Electric 1 Developer will need to coordinate power requirements and electric development charges with Light & Power engineering (221-6700). Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Drainage 9 Stormwater review is incomplete due to largely incomplete submittal. Grading plan is undecipherable and confusing. Submittal is lacking required minimum specifications for review. Included is a partial checklist of specifications required for submittals. If you have any questions or would like to set up a meeting, please call Wes Lamarque or Glen Schlueter at 221-6700. Topic: Erosion/Sediment Control 10 1. Please submit an erosion control surety calculation. 2. Please change plan note #2 to indicate what the plan shows, that silt fencing will be installed on the south, east, and north perimeters of the project. Department: Water Wastewater Issue Contact: Jeff Hill Topic: Site and Landscape 2 Show all existing and proposed water/sewer lines on the landscape plans and provide the required landscape/utility separation distances. Topic: utility plan 3 all existing water and sewer stubs must be used or abandoned at the mains. Show all existing water/sewer stubs and clearly define whether they are to be use or abandoned. Clearly define all abandonment procedures. 4 If food preparation is to be performed on site, then a grease trap will be required. Show and label location as well as provide grease trap detail. 5 Show and label locations of existing gas and electric mains on the overall utility plans. Provide a minimum 4 feet of separation between proposed curb stops/meter pits and gas/electric mains. Page 1