HomeMy WebLinkAboutEAGLE CLIFFS - FDP - 22-02A - CORRESPONDENCE -3
A utility coordination meeting is encouraged. The developer can contact Light & Power Engineering (221-
6700) to request a design of the electric system. There is a $50.00 per lot deposit required to initiate the
electric design. This deposit will be credited to normal electric development charges if the electric system
doesn't need to be re -engineered when the plat/utility plan is approved.
99
Previous L&P comments from round 1 still apply.
Department: PFA Issue Contact: Michael Chavez
Topic: Site Plan
96
All previous comments have been acknowledged and resolved.
Department: Police
Topic: Landscaping
72
No comments.
Issue Contact: Joseph Gerdom
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Erosion/Sediment Control
105
1. It is still unclear looking at the erosion control plan what is to be done to revegetate the area south of the
houses north of Fossil Creek and in the detention pond. One small note indicates reseeding per the
landscape plan. Reseeding alone won't protect an area until whatever is planted grows. If the seeding is
done in December or later, it won't grow until spring. All disturbed areas need to be stabilized within 30 days
unless otherwise authorized by Stormwater. It would be good to include a note on the detention pond, also
to include mulching with the seeding.
Topic: Floodp/ain
106
Please see minor comment on site and landscape plans.
Department: Transportation Planning Issue Contact: Tom Reiff
Topic: General
88
No comments
Department: Zoning Issue Contact: Gary Lopez
Topic: Zoning
83
Please indicate on elevations over all height of multi family units.
Red lined drawings are available at the Current Planning front desk. At a minimum,
Engineering, Technical Services and Stormwater will need to see revised prints
before mylars may be submitted. Be sure and return all of your redlined plans when
you re -submit.
If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at (970) 221-6750.
Yours Truly,
Bob Barkeen
City Planner
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
VF RIPLEY ASSOCIATES Date: 11 /26/2002
C/O RACHEL LINDER
401 WEST MOUNTAIN AVENUE, SUITE 201
FORT COLLINS, CO 80521
Staff has reviewed your submittal for EAGLE CLIFFS PDP & FC, and we offer the
following comments:
ISSUES:
Department: Current Planning Issue Contact: Bob Barkeen
Topic: General
80
The front elevation of patio home 'C' does not appear to meet the requirements of Section 3.5.2(E), garage
setback 4 feet from the face of the dwelling.
98
Building colors are not included with the building materials/elevations. Please include this information. Multi-
family buildings should have a different color for each building.
Department: Engineering Issue Contact: Katie Moore
Topic: General
86
Please see plans for any additional comments.
100
The parking spaces in the cul-de-sac should be 19' deep to the face of curb even with the overhang
(LCUASS Dwg 19-Ola)
101
Driveways used instead of ped. Ramps need to meet ADA requirements. One driveway in the cul-de-sac
also needs to meet ADA requirements. Please see the attachment and include the detail in the plans.
102
Reminder - Mylars will not be signed until the City is provided copies of the completed offsite easements.
Topic: Plat Cover Sheet
104
The notary should be located in Larimer County, not Weld County.
Topic: UP sheet 11
103
The cross -slopes in the cul-de-sac bulb are not meeting the minimum of 2%. Please correct. The slope within
the parking spaces there also does not appear to meet the 2% minimum.
107
Please add a line showing the crown going into the cul-de-sac.
Topic: UP sheet 4 and 5
92
Please provide at least 2' of leeway before grades drop off beyond back of sidewalks.
(11.19.02) The 2' of leeway is required whether the slope drops off or rises.
Department: Light & Power Issue Contact: Doug Martine
Topic: Utilities
2
Due to minimal utility construction space, locations of driveways, electric & gas meters must be determined
prior to approval. Once these have been agreed to the locations cannot be changed.
Page 1