HomeMy WebLinkAboutHOWES/CANYON MIXED-USE (CORTINA) - PDP - 45-02 - CORRESPONDENCE - REVISIONS (3)Number 76 There is a note on this profile that requires all joints be encased on this storm run. Number 77 The correct Water and Sewer Services have been shown on the Landscape Plan. We were asked to remove all utilities from the Site Plan by the Zoning Department during the last round of comments. Utility Plans Number 106 The floor drains will be connected to the storm. This will be detailed with the building plans — Sand -oil separator was removed. Zoning Number 78 The project name will be Cortina (Canyon/Howes Mixed Use Building) Please let us know if you have any further issues or questions about this project. Sincerely, Cathy Mathis VF Ripley Associates Stormwater Utility General Number102 Variance is attached. Number103 Revised grading in driveway to address this concern. High point is T' above flowline in street. Number104 See revised. Number105 Added flow calculation to report. Basin was previously defined. Erosion/Sediment Control Number 65 There will be inlet protection around the existing inlet. Because of the existing street and curb that we wish to salvage, this is the best we can do. Transoortation Plannina Parking Number 58 The bike rack has been relocated along Canyon Avenue at the northwest corner of the building. Also, bike parking is available in the underground parking level for the residents. Number 59 The handicap parking stall has been moved from the little parking lot to Canyon Avenue, farther north than was requested by Transportation Planning. This location works better for grades and accessibility. Water/Wastewater General Number 73 Revised note as requested Number 74 Added stationing as requested. Number 75 Added lowering detail to sheet 11. Number 81 The ramp has been changed. Overall Utility Plan Number 39 Added information as requested Number 82 Both driveways are concrete to ROW Number 83 This will be drained into a sump and pumped out of the building. Since it is inside the building, it will be detailed with the building plans. Site Plan Number 13 We are in the process of obtaining an encroachment permit. Number 16 Redlines have been addressed on the site and landscape plan. Storm Drain Profile Number 98 See revised notes. Utility Plan Cover Sheet Number 79 Revised benchmark information. Number 91 Revised numbering as requested. Light & Power: General Number 72 Acknowledged. PFA General Number 93-97 All Acknowledged. Number 85 Centerline stationing was provided on previous submittal. See redlines. Number 86 Revised slope to 0.5% minimum. Detail Sheet Number 87 Removed details as requested. Revised ramp detail as requested. Number 89 Added detail #1101. Number 101 Added detail as requested. Drainage Number 88 Layers were turned on as requested. General Number 36 Revised as requested. Number 90 A letter of intent has been submitted to the Engineering Dept. Number 92 The applicant feels that it is not necessary to obtain an easement from the property owner to the south of the Linden Press. The construction staging area will be located along Canyon Avenue and on the small parking lot area on -site. Number 99 Roof drains are collected underground and piped to the Stormceptor — the only water going through the stormceptor Number 100 At this point, all we have is what is on the utility plans. The applicant will be utilizing a structural engineer as the architectural plans become more finalized. Grading Plan Number 28 Contour lines are provided. In this small of an area, the spots better represent the grading rather than the contours. Number 80 The ramps for the driveways now match. 0 \/ F:F1 iiP'GyASSOCIATES INC Landscape Architecture Urban Design Planning April 4, 2003 Bob Barkeen City of Fort Collins Planning Department 281 North College Avenue PO Box 580 Fort Collins, CO 80522 RE: Response to Staff Comment letter dated March 12, 2003 Dear Bob, RECEIVED ,`"� 0 rl %.3 CURRENT PLANNING The comments below address the issues raised by city staff regarding the Cortina (Canyon/Howes Mixed Use Building) Advanced Planning Redlined Site Plan: We have gladly accommodated the requests of the Advanced Planning Department. The 909 turn at the corner has been softened. There is now a more continuous lower level sidewalk. For handicap access reasons, we had to have a ramp at both ends of the upper level sidewalk. The lower level walk has been increased to 7' wide along the entire Canyon Avenue frontage as requested. Current Planning: Utility Plans Number 107 The underground storage issue has been resolved. We are showing the new layout -on the Utility Plans sheets. The number of parking spaces has been changed to match the latest parking garage plans. Number 108 A modification request has been submitted and it is the applicant's desire to have both the Modification and the PDP go the P & Z at the same time. Engineering: Canyon Avenue Profile Number 84 Elevations were added as requested on profiles. Phone 970.224.5828 Fax 970.224.1662 401 West Mountain Ave. Suite 201 Fort Collins, CO 80521-2604 vtripley.com