HomeMy WebLinkAboutCAMBRIDGE LOFTS APARTMENTS - FDP - 6-03D - CORRESPONDENCE - (3). . . 0 Water/Wastewater: 1. If there is to be a restaurant(s) in the "common space" in the building then a grease interceptor would be required. 2. The 2" water service must be for residential. The notes on the utility plan must be flipped. Light & Power: 1. The existing transformer is the electric source for this building. It needs to be in a utility easement. Some of the transformers in this area are old and antiquated and maybe should be replaced. Transportation Planning: 1. Handicapped ramps need to be shown on the utility plans and they must meet the ADA accessibility requirements. 2. How does the western drive into this site tie into the existing curb, gutter, and sidewalk along Plum Street? Planning: 1. It is being suggested that the applicant look further at the architecture on the north and south sides of the building. Is there to be windows, glazing on the 3zd floor? 2. It is being suggested that Boston Ivy be added to the north side of the building and 2 ornamental trees be included in the planting area on the south side of the building. Be sure and return all redlined plans if or when a re -submittal is made. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, Steve Olt, City Planner cc: Susan Joy Chris Ray Tricia Kroetch Current Planning File #6-03D Page 4 [5/18/041 There are minor discrepancies between the utility plans and the site and landscape plans. Please clean up the Plum Street sidewalk configuration between the plan sets. Keep in mind that the sidewalk needs to continue to the edge of the property line and connect to the existing sidewalk. [1/12/04] The sidewalk along Plum Street will need to continue to the edge of the property line to the east. Please include a sidewalk that crosses the driveway to the eastern property line (see red lines for alignment). Department: Water Wastewater Issue Contact: Roger Buffington Topic: Plat Number: 111 Created: 5/21/2004 [7/14/041 [5/21/041 Will there be any restaurants in the building? If \so, provide grease interceptor. Topic: Utility Plans Number: 128 Created: 7/14/2004 [7/14/04] Check labeling of water services. A 1" water service is not adequate for 12 units. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 14 Created: 12/19/2003 [7/6/04] Same comment [12/19/03] Label building envelope, footprint, dimensions, and distance to property lines. The following comments were expressed at staff review on July 14, 2004: Engineering: 1 Engineering is ready for mylars. 2. The easement along Plum Street must be labeled on the Site & Landscape Plans. Stormwater: 1. The Finished Floor Elevation of the building is not high enough. Stormwater has already talked to Trisha Kroetch, the applicant's engineer, about this. Page 3 Topic: Site Plan Number: 90 Created: 5/10/2004 (7/13/041 Please correct the easement along Plum to be a 24' Public Access and Utility Easement (see utility and plat plans). [5/10/041 Site plan does not match the utility plans. Topic: Utility Plans Number: 92 Created: 5/10/2004 [7/14/041 Correction required to the emergency access easement variance. The min widths and radii were not met at the "pinch" point and it needs to be reworded to reflect that. [5/10/041 Sheet 2 - please be a little more specific on the variance granted in line 48. Include the section, the actual requirement, and then the variance itself. Also, include the variance to the emergency access easement minimum widths and radii granted by PFA. Department: Natural Resources Issue Contact: Doug Moore Topic: General Number: 129 Created: 7/14/2004 [7/14/041 No issues. Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Drainage Number: 126 Created: 7/13/2004 The F.F. elevation for the building needs to be 18-inches above the flowline of the gutter in Shields. This is required due to the flow depth allowed in an arterial street to be 18-inches in the 100-year storm. Number: 127 Created: 7/13/2004 Please change detail of 5-foot chase to have a 6-inch concrete support. See redlined plans. Department: Transportation Planning Issue Contact: Tom Reiff Topic: Transportation Number: 84 Created: 1/12/2004 [7/13/041 The additional ramps along the walkway connecting Shields St. to the existing Cambridge House apartment complex are still not shown on the utility plans. Please correct. [5/18/041 A few additional access ramps still need to be added to the plans (see red lines). [1/12/041 Please include all access ramps associated with sidewalks on all the plan sets including the utility and site plans. Number: 87 Created: 1/12/2004 (7/13/041 Utility plans need to clearing show how the sidewalks changes along Plum Street will connect to the existing sidewalk. Page 2 STAFF PROJECT REVIEW Citvof Fort Collins e Eastpoint Studio Date: 07/21/2004 c/o Donald Brookshire 3207 Kittery Court Fort Collins, CO. 80526 Staff has reviewed your submittal for CAMBRIDGE LOFTS APARTMENTS, FC - TYPE I (LUC), and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 130 Created: 7/21/2004 [7/21/041 The Current Planning Department is ready for mylars of the Site Plan, Landscape Plan, Building Elevations, and subdivision plat (3 sets of the plat, at least 1 with original signatures) to be submitted. Department: Engineering Issue Contact: Susan Joy Topic: General Number: 125 Created: 7/13/2004 [7/13/041 Ready for mylars with the remaining items addressed (do not need to resubmit). Topic: Landscape Plan Number: 26 Created: 12/23/2003 [7/13/041 Please correct the easement along Plum to be a 24, Public Access and Utility Easement (see utility and plat plans) and show the emergency access easement. [5/10/041 Repeat comment. [12/23/031 Show all utilities and easements (dimensioned and labeled). Topic: Plat Number: 109 Created: 5/18/2004 (7/13/041 (5/18/041 From Technical Services: Boundary and legal close. Number: 123 Created: 7/13/2004 (7/13/041 Repeat from last round of redlines: What are all the extra leaders for? Number: 124 Created: 7/13/2004 [7/13/041 From Technical Services: Typo in Legal, Section 12 should be Section 15 (see redlines). Page 1