HomeMy WebLinkAboutCAMBRIDGE LOFTS APARTMENTS - PDP - 6-03C - CORRESPONDENCE -(12/19/03) The tree cut-outs donl count as landscape dislands and don't break up the parking aisles into 15
or fewer spaces in a row. Please review - also it creates 2 non -conforming spaces that are too short - but
people will still attempt to park in them - but not be able to pull all the way forward.
Number: 10 Created: 12/19/2003
(12/19/03) North end parking aisle shows 16 spaces, southe nd shows 17, only 15 in a row without an
intervening island are allowed
Number: 11 Created: 12/19/2003
(12/19/03) Would prefer the site plan to only show site itmes, not landscape items - the landscaping is/should
be shown on the landscape plan
Number: 12 Created: 12/19/2003
(12/19/03) Plant Notes #4 - add of working - value of landscpaing "and installation"
Number: 13 Created: 12/19/2003
(12/19/03) On the south end where the diamond cut-out for the tree is located there is only 2.5 ft og sidewalk
- check with engineering on their standards
Number: 14 Created: 12/19/2003
(12/19/03) Label building envelope, footprint, dimensions, distance to property lines
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
plea feel free to call me at (970) 221-6750.
Yo s Trul ,
I
Troy One !
City lann r
Page 8
Stormwater is ready for hearing. Additional comments may follow during final plan submittal
Number: 56 Created: 1 /1 /2004
Please coordinate the landscape plan with the utility plans. Shrubs are proposed over the concrete pan
Topic: Erosion/Sediment Control
Number: 57 Created: 1 /1 /2004
1. Please provide required calculations to support plan and surety calculations at final plan review. -
2. The site slopes west to east, yet there is no protection along Shields Street. What protection will be
provided there to protect areas downstream?
Department: Traffic Operations
Topic: Traffic Study
Number: 54
(12/15/03) The TIS dated 12/08/03 is acceptable.
Department: Transfort
Topic: General
Number: 53
[12/31/03] No comments.
Issue Contact: Eric Bracke
Created: 12/31 /2003
No issues from Traffic Operations
Issue Contact: Garold Smith
Created: 12/31 /2003
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: General
Number: 45 Created: 12/30/2003
(12/30/03) Use a tapping saddle to make the fire line connection to the existing water main. Label fire line as
Ductile Iron Pipe (D.I.P.).
Number: 46 Created: 12/30/2003
(12/30/03) Separate water and sewer services are required for each use (i.e. commercial verses residential).
Number: 47 Created: 12/30/2003
(12/30/03) Curb stop and meter pit may not be located in the sidewalk or any other traveled way.
Number: 48 Created: 12/30/2003
(12/30/03) Provide a 10 foot utility easement on either side of the existing sanitary sewer main. Maintain 10
foot clear separation between the existing sanitary sewer main and any permanent structure (i.e. trash
enclosure, canopies, etc.). Will existing sanitary sewer manhole covers need to be raised or lowered? If so,
provide all detail necessary.) Provide a water tight manhole cover for the existing manhole which will be
located in the proposed curb and gutter.
Number: 49 Created: 12/30/2003
(12/30/03) Maintain the required landscape/utility separation distances on the landscape plans.
See site, landscape and utility plans for other comments.
Department: Zoning Issue Contact: Jenny Nuckols
Topic: Landscape Plan
Number: 52 Created: 12/31 /2003
(12/18/03) The tree cut-outs donl count as landscaped islands and son't break up the parking into rows of 15
or fewer spaces
Topic: Zoning
Number: 9 Created: 12/19/2003
Page 7
3. Compacted road base shall be used during the construction phase only. The permanent fire lane shall
consist of asphalt or concrete and shall be required to support 40 tons
4. The fire lane shall be platted as an "Emergency Access Easement' on the final plat.
1997 UFC 901.2.2.1; 901.3; 901.4.2; FCLUC; PFA Policy 85-5 (B)
Number: 4 Created: 12/18/2003
[12/18/031 ADDRESS NUMERALS:
Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch
numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable).
NOTE: If addressed off 1113 W. Plum St., an addressing pattern that coincides with existing buildings shall be
maintained.
1997 UFC 901.4.4
Number: 5 Created: 12/18/2003
[12/18/031 WATER SUPPLY: Commercial
No commercial building can be greater then 300 feet from a fire hydrant.
Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must
be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2
Number: 6 Created: 12/18/2003
[12/18/031 SPRINKLER REQUIREMENTS:
Buildings that are three or more stories in height shall be fire sprinklered. There shall be a minimum 6-inch fire
line unless hydraulic calculations can support a smaller fire line.
1997 UFC 1003.2.9: 902.2.1
Number: 7 Created: 12/18/2003
[12/18/031 FIRE ALARM REQUIREMENTS:
A fire alarm system is required for this proposed project. 1997 UFC 1007.2.9.1.1
Number: 8
Created: 12/18/2003
[12/18/031 KNOX BOX:
Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new building equipped with a
required fire sprinkler system or fire alarm system.
1997 UFC 902.4; PFA POLICY 88-20
Department: Police
Topic: General
Number: 43
Issue Contact: Joseph Gerdom
Created: 12/29/2003
(12/29/03) Lighting Plan needed. Recommend that ground access to stairwells be well lit, avoid landscape
materials that provide concealment, provide openings - viewports - in stairwell design. Need specific type
and location of plant materials.
Department: Streets
Topic: General
Number: 69
(1/8/04) OK.
Department: Stormwater Utility
Topic: Drainage
Number: 55
Issue Contact: Beth Sowder
Created: 1 /8/2004
Issue Contact: Wes Lamarque
Created: 1 /1 /2004
Page 6
Number: 39
(12/23/03) Sheet 3, Add the street cut note:
Created: 12/23/2003
Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering
Inspector. All repairs to be in accordance with City street repair standards.
Number: 40 Created: 12/23/2003
(12/23/03) Provide details: 701, 702, 707, 1601, 1602, 1606
Department: Excel Energy Issue Contact: Len Hilderbrand
Topic: General
Number: 72 Created: 1 /8/2004
[1/8/04] Any relocation, cutoff's or installation of gas facilities will be at developers expense.
Number: 73 Created: 1 /8/2004
[1/8/04] No trees planted with in 4' of gas lines. (existing or future mains, services, etc.)
Number: 74 Created: 1 /8/2004
[1/8/04] Plat shows wrong legals for area/ 67W Should be/ 15. 7N. 69W
Department: Light & Power Issue Contact: Doug Martine
Topic: Light & Power
Number: 1 Created: 12/12/2003
(12/12/03) The developer will need to coordinate power requirements, transformer locations, and electric
development charges with Light & Power Engineering (970)221-6700.
Number: 2 Created: 12/12/2003
(12/12/03) The existing transformers serving Cambridge apartments will need to be relocated. The existing
wood fence enclosure around these transformers is not Light & Power approved anyway.
Department: Natural Resources Issue Contact: Doug Moore
Topic: Tree Preservation Standards
Number: 42 Created: 12/29/2003
(12/29/03) Contact Tim Buchanan, City Forester for an evaluation of existing trees to be removed. If trees are
being mitigated then mitigation trees need to be shown and labeled on landscape plan. Limits of
development (L(?D), details showing protective fencing and tree protection notes are also needed in utility
set. Notes may be obtained from the City Forester. L.U.C. 3.2.1(F), 3.2.1(G)
Department: Park Planning
Topic: General
Number: 70
[1/8/04] No comment.
Issue Contact: Craig Foreman
Created: 1 /8/2004
Department: PFA Issue Contact: Michael Chavez
Topic: General
Number: 3 Created: 12/18/2003
[12/18/031 .REQUIRED ACCESS:
A fire lane is required. The fire lane shall be visible by painting and signage, and maintained unobstructed.
The criteria for a required fire lane contain several conditions that must be met.
1. Buildings three stories or more in height must have access to a 30 foot unobstructed access roadway
on at least (1) one side for aerial operations.
2. Inside turning radius shall be 25 feet and outside turning radius shall be 50 feet.
Page 5
0
Number: 32 Created: 12/23/2003
(12/23/03) Dedicate the fire Zane on the plat, label as "Emergency Access Easement".
Number: 33
(12/23/03) Provide two ties to aliquot corners.
Created: 12/23/2003
Number:77 1 Created:l/9/2004
(1 /9/04) All of the plat language is wrong. Please see the attached for the correct language.
Number: 78 Created: 1 /9/2004
(1 /9/04) Correct the project title.
Number: 79 Created: 1 /9/2004
(1 /9/04) Spell out all abbreviations.
Number: 80 Created: 1 /9/2004
(1 /9/04) Dedicate the emergency access lane required by PFA.
Number: 81 Created: 1 /9/2004
(1 /9/04) See comments under General that effect the plat. See redlines.
Topic: Site Plan
Number: 20 Created: 12/23/2003
(12/23/03) Show all easements, label and dimension.
Number: 21 Created: 12/23/2003
(12/23/03) Remove landscaping.
Number: 22 Created: 12/23/2003
(12/23/03) Remove contours.
Number: 23 Created: 12/23/2003 .
(12/23/03) Correct all overlapping labeling and increase font size to meet the minimum requirement. See
appendix E6 for additional sconability, requirements.
Number: 24 Created: 12/23/2003
(12/23/03) Dimension Scott Avenue ROW, existing and proposed.
Topic: Utility Plans
Number: 34 Created: 12/23/2003
(12/23/03) Correct the preamble title to read "Utility Plans for..."
Number: 35 Created: 12/23/2003
(12/23/03) Provide two project bench marks referencing the City's datum.
Number: 36 Created: 12/23/2003
(12/23/03) See Bob Zakely for revegatation methods and specific notes required on the plans.
Number: 37 Created: 12/23/2003
(12/23/03) Show, dimension, and label the fire lane required by PFA.
Number: 38 Created: 12/23/2003
(12/23/03) See the attached checklist for other comments. The highlighted items were reviewed with the first
round of review. The remaining items are reviewed after hearing and in the final compliance review.
Page 4
Number: 19 Created: 12/23/2003
(12/23/03) Dimension Scott Avenue ROW, both existing and proposed.
Topic: General
Number: 15
Created: 12/23/2003
(12/23/03) Project title needs to be consistent between the plan sets. All sets should read "Cambridge House
Lofts" or whatever the project title is that you decide on.
Number: 41 Created: 12/23/2003
(12/23/03) This project is responsible for dedicating their half of the current local street width (5l'total) and
for the design and construction of Scott Avenue. There is currently 20' of ROW for Scott Avenue. That means
that this project needs to dedicate an additional 15.5, or (51-20)/2. However, you may dedicate the
additional width as a Public Access, Utility, and Drainage Easement instead so that the applicant still retains
the current use of the property as currently shown.
In addition, this project is responsible for dedicating their half of a minor collector with parking along Plum.
There is currently 40' of ROW and a total of 76' is needed. That means that this project must dedicate an
additional 18' of ROW on Plum. They do NOT need to dedicate the utility easement along Plum.
No additional ROW along Shields is required.
Number: 50 Created: 12/31 /2003
(12/31 /03) A variance request will need to be submitted by a licensed engineer if the emergency access
easement does not meet standards.
(9/25/03) From the modification request: Upon submittal of a PDP, the fire lane must meet the minimum
requirements as shown in 7.8 of LCUASS and the Emergency Access section 3.6.6 in the COFC Land Use
Code. Such emergency access lanes must be in a dedicated emergency access easement (can be done
by separate document). Please contact PFA to determine if such easements are required. Please label and
dimension the width and inner/outer radii of the emergency access lane so that we can determine whether
or not the lane meets minimum requirements.
Topic: Landscape Plan
Number: 26 Created: 12/23/2003
(12/23/03) Show all utilities and easements (dimensioned and labeled).
Number: 27
(12/23/03) Remove contours.
Created: 12/23/2003
Number: 28 Created: 12/23/2003
(12/23/03) See appendix E6 for sconability requirements.
Topic: Plat
Number: 29 Created: 12/23/2003
(12/23/03) Most of the plat language shown is incorrect. Please seethe attached for the correct plat
language.
Number: 30 Created: 12/23/2003
(12/23/03) Spell out all abbreviated easement labels.
Number: 31 Created: 12/23/2003
(12/23/03) Change the "Pedestrian Access Easement' along Plum Street to read "Public Access Easement'.
Page 3
(1 /8/04) Scott Avenue is a public street directly west of the site. It is gravel and the right of way is only 25 feet
wide. At some point in the long mid to long term future, Scott Avenue will likely be widened and improved
by the creation of some sort of Special Improvement District or some other mechanism. Although such
improvements would not likely happen anytime soon, such widening would impact the parking along the
west edge of Cambridge House Apartments.. If Scott Avenue were to have a right of way width in
accordance with the local residential street standard, the right of way would need to be 51 feet wide. This
would mean that an addition 15.5 feet would be needed from the Cambridge House apartments property to
accomplish this. One potential solution staff is considering would be to have this project dedicate a 15.5 foot
wide access easement along the western edge of the property. The conditions by which the City would
exercise the use of this area would need to be carfully spelled out in the development agreement. It would
also need to be clarified in the developent agreement that the loss of on -site parking as a result of Scott
Street being built would need to be somehow accommodated by on -street parking, or some other solution
that doesn't adversely affect Cambridge House Apartment. I'm in the process of coordinate schedules, we
should meet on this issue next week.
Number: 66 Created: 1 /8/2004
(1 /8/04) The scale on the conceptual landscape plan and the site plan seems to be the some but one is
labeled at 1 "=20' and the other is labeled at 1 "=30'. Please clarify.
Number: 67 Created: 1 /8/2004
(1 /8/04) Specify colors of materials on the elevotions.and bring in samples of the brick and concrete block.
Number: 68 Created: 1 /8/2004
(1/8/04) We can tentatively plan to take the project to the Feburary 19th Planning and Zoning Board
meeting, provided we come to an agreement on how best to deal with Scoff Avenue.
Number: 75
[1/8/04] Water Conservation has no comments.
Created: 1 /8/2004
Number: 76 Created: 1 /8/2004
[1/8/04] See the attached comment sheet from Building Inspection.
Number: 82 Created: 1 /9/2004
(1/9/04) See attached redlines from Current Planning.
Number: 83 Created: 1 /9/2004
[1/9/04] The sidewalk along the south side of the new building must be a minimum of 6 feet wide [LUC
3.2.2(C)(5)]•
Topic: Plat
Number: 59 Created: 1 /8/2004
(1 /8/04) The plat is not a minor subdivision. We don't do minor subdivisions anymore. The plat should also be
titled "Cambridge Lofts Apartments PDP."
Department: Engineering
Topic: Existing Site Plan
Number: 16
(12/23/03) Remove landscaping.
Number: 17
Issue Contact: Susan Joy
Created: 12/23/2003
Created: 12/23/2003
(12/23/03) See appendix E6 for scanability requirements. Correct all overlapping labeling and increase the
font size to meet the minimum.
Number: 18 Created: 12/23/2003
(12/23/03) Sidewalk is shown between the two driveway entrances on Plum but no sidewalk to the east and
west of those some drives. Is there any existing out there? If so, please show. If not, why not?
Page 2
J
STAFF PROJECT REVIEW
City of Fort Collins
EASTPOINT STUDIO Date: 01/09/2004
DONALD BROOKSHIRE
3207 KITTERY CT
FT. COLLINS, CO 80526
Staff has reviewed your submittal for CAMBRIDGE LOFTS APARTMENTS PDP - TYPE I
(LUC), and we offer the following comments:
ISSUES:
Department: Post Office
Topic: General
Number: 71
[1/8/04] No Concerns.
Department: Current Planning
Topic: General
Number: 58
Issue Contact: Carl Jenkins
Created: 1 /8/2004
Issue Contact: Troy Jones
Created: 1 /8/2004
(1 /8/04) The Conceptual Landscape Plan calls the project "Cambridge House PUD." The Existing Site Plan
and the proposed Site Plan calls the project "Cambridge Lofts." The elevation sheet calls the project
"Cambridge House Lofts." All sheets need to use the some name. Also, the project is a Project Development
Plan, not a PUD. We have therefore entered the name in our system as "Cambridge Lofts Apartments PDP."
Please change the title of all drawing sets, including civil engineering drawings to this name. If you don't like
the name we chose, you can choose a different one. Let us know what you want the name to be and make
sure all the drawing sheets say the new name.
Number: 60
Created: 1 /8/2004
(1 /8/04) Shrubs are shown within an area shown on the utility plans to be a concrete channel at the
southeast corner of the site. Please resolve this conflict.
Number: 61 Created: 1 /8/2004
(1 /8/04) Donl show any trees on the site plan, only show them on the landscape plan. This includes not
showing existing trees.
Number: 62 Created: 1 /8/2004
(1 /8/04) Advance Planning, Current Planning and Transportation Planning all need to review a detail at a
larger scale to the sidewalk and landscape areas on the east and south sides of the new Shields Street
building. As currently shown, it's just too small of a scale to get an understanding of what's exactly proposed.
It's not clear what's proposed within the planting beds, and the paving patterns are a little confusing at this
scale.
Number: 63 Created: 1 /8/2004
(1 /8/04) Along the northeastern corner of the site, extend a sidewalk along the street frontage. If the existing
tree is in the way, it can be removed, because it is considered a nusionce species of tree. Tim Buchanan, the
City Forester should be contacted first.
Number: 64 Created: 1 /8/2004
(1 /8/04) The new tree porposed along the south property line midway between the new building and the
existing apartments is not considered to be feasible to have there because of the location of the sewer line in
that vicinity. You should remove this tree from the plans. The landscape diamond should remain where
shown, but have a shrub.
Number: 65
Created: 1 /8/2004
Page 1