HomeMy WebLinkAboutCSU SOUTH DORMITORY - SITE PLAN ADVISORY REVIEW - 50-02A - CORRESPONDENCE - (3)20. Any damage to public sidewalk, curb, gutter or any other appurtenances must be repaired or replaced as necessary. 21. The Engineering Department will require submittal of Utility Plans for installation of underground utilities and other public improvements. A Utility Coordination meeting will be necessary, especially since Pitkin is private. Dedication utility easements will need to be arranged among all the utility providers. In addition, emergency access easements will necessary. 22. Parking stalls must be setback from the public street by the minimum distance which is determined by the level of traffic volume on the public street. Driveways along Pitkin should align or should be separated by a sufficient distance. 23. In the parking lot, be sure to provide walkways that are separate and distinct from the drive aisles in order to prioritize the pedestrian and minimize conflicts with cars. 24. A Development Construction Permit is required. The baseline fee is $300 and then fees are added incrementally as per the number of inspections that are required. For further information regarding civil engineering issues or preparation of the Utility Plans, please call Sheri Wamhoff, 221-6605. 25. For an estimate of the Capital Improvement Expansion Fee, payable at the time of building permit, please contact the Building Inspection Division, 221-6760. Keep in mind fees are adjusted annually. 26. The Department of Natural Resources provides "climate -wise" information with regard to building and land development. Please contact Sandy Hicks, 221-6600. 27. The Department of Natural Resources advises that any existing trees be inspected by the City Forester. If found to be significant, and if the trees are to be removed, then mitigation trees must be provided. The construction phase will require a Fugitive Dust Permit from the Larimer County Health Department. Also, trash enclosures should be sized to accommodate various containers for recycling. A single trash hauler should be used. For further information on natural resource issues, please contact Doug Moore, 221-6750. 28. A neighborhood meeting will be required. Please contact the Planning Department when you are ready to proceed to this stage. We will prepare an area notification map. You are responsible for providing self-adhesive mailing labels for all property owners of record within the notification area. Postage is $.50 cents per name. The City Current Planning Department will set up and moderate the meeting. existing 15-inch diameter sanitary sewer in Shields. There is an existing 10-inch diameter sanitary sewer in Lake Street connecting to the eight -inch that runs northwest through the proposed parking lot, and then to Burton/James Court. There is an existing six-inch water line connecting to an eight -inch waterline in James Court. Any cutting of a public street will require a permit from the Engineering Department. 14. The water main system should be looped to the 18-inch line from Shields to James. An estimate of the wastewater flows must be provided to determine sewer capacity. 15. Water conservation standards for landscaping and irrigation will apply. Plant investment fees and water rights (or cash -in -lieu) are due at the time of building permit issuance. The fees are based on the size of the water tap. The raw water requirement is based on estimated annual usage. In addition, there is a small plan inspection fee. For further information regarding water and sewer issues, please contact Roger Buffington, 221- 6681. 16. The site will be served by the Poudre Fire Authority. They will require that a fire hydrant be within 300 feet of the building capable of delivering a minimum of 1,500 gallons per minute at 20 p.s.i. An automatic fire extinguishing system will be required. An automatic fire alarm system will be required. A fire pump may be required depending on water supply. The contractor providing the fire protection systems must be licensed in the City of Fort Collins and submit plans. A permit will be issued upon complete review of plans and all criteria addressed. The drive on the west side must be a designated fire access road. One other side of the building must be accessible as well. Designated fire lanes must feature curbs painted red and "No Parking — Fire Lane" signs. The address must be visible from the public street on which the building fronts. For further information, please contact Ron Gonzales, 221-6570. 17. The Street Oversizing Fee will be payable at the time of building permit issuance. Please contact Matt Baker, 970-221-6605 to determine an estimate of this fee. In addition, the City collects the Larimer County Road Fee. Keep in mind these fees are adjusted annually. 18. A Transportation Impact Study will be required. Please contact Eric Bracke, Traffic Operations Engineer, 221-6630, to determine the scope of the study. A T.I.S. must also address alternative modes such as bike, pedestrian and transit levels of service. Please be aware that the T.I.S. may indicate the necessity of constructing off -site public improvements in order to provide safe access to and from the project for all modes. For example, a sidewalk may be needed to connect the project to the existing transit stop on Shields Street. 19. Please contact John Daggett, Senior Transportation Planner, 221-6190, who worked with C.S.U. on the campus transportation master plan. Non -vehicular access to the main campus needs to be promoted and facilitated. Raised crosswalks should be provided across Pitkin. 4. There are a variety of other development standards in the H-M-N zone. These are found in Section 4.24(E) of the Land Use Code. Also, there are residential building standards in Section 3.5.2. Wherever these standards conflict, Section 4.24 shall prevail. 5. Please consider providing special amenities for bicycle parking since the site is part of the C.S.U. campus. Be sure to provide the required minimum in accordance with Section 3.2.3. Bike parking should be spread around the facility for convenience. 6. Electrical power will be provided by Fort Collins Utilities. The source is from existing system at the northwest corner of the site. The location of the transformer and meter must be coordinated with Light and Power. The transformer must be both accessible (within ten feet) to hard surface for emergency change -out and screened for safety and aesthetic purposes. 7. A Commercial One ("C-1") Form must be completed by a licensed electrical contractor to determine entrance capacity. The construction phasing schedule should be coordinated with Light and Power. Normal electrical development fees and charges will apply. Light and Power will have to make a determination as to whether the project is considered commercial or residential. Any change to the existing electrical system or facilities will be at the developer's expense. Since Pitkin is private, Light and Power will not provide streetlighting. 8. The existing overhead power line must be placed underground and located in a dedicated utility easement of sufficient width as determined by the Light and Power. 9. Please be aware that on the west side of the north -south drive, there should be sufficient land area set aside for the placement of electrical transformers that may be needed to serve the larger area. For further information, please contact Rob Irish, 221-6700. 10. This site is in the Spring Creek drainage basin where the new development fee is $2,175/acre which is subject to the runoff coefficient reduction and due with building permit issuance. For monthly fees, please contact Jean Pakech at 221-6700. 11. The site is on Stormwater inventory map #6J. A copy can be obtained from the Utilities office at 700 Wood Street. Onsite detention with a two-year release rate is required and extended detention is needed to treat the runoff. The standard drainage and erosion control reports and construction plans are required and they must be prepared by a professional engineer registered in Colorado. 12. The outfall for the site is the stormsewer in Pitkin Street which is undersized so that is why onsite quantity detention is required. If parking lot detention is proposed, it must not be deeper than one foot. For further information, please contact Glen Schlueter, 221-6700. 13. There is an existing six-inch diameter water main in Shields. There is an existing 18-inch diameter water main running north -south about 400-500 feet east of the site. There is an CONCEPTUAL REVIEW STAFF COMMENTS City of Fort Collins ITEM: C.S.U. Student Housing — Main Campus MEETING DATE: October 10, 2002 APPLICANT: Mr. Mathew Thompson, Kiewit Construction, 7200 S. Alton Way, Bldg. A, Suite 300, Englewood, CO. 80112 LAND USE DATA: Request for a 700-student undergraduate student dormitory located on the south side of West Pitkin Street, on the site of the Ropes Course, south of Ellis and Edwards Halls. There will be no food services. There would be 175 two -room suites, each suite having the capacity of four persons. The building would be three -stories. There would be parking for about 200 cars (with the option of developing and adjacent property to allow a total of 350 cars). The site is 4.7 acres. The building footprint is 33,000 square feet. COMMENTS: The site was mistakenly considered part of the C.S.U. main campus in March of 1997 when the city-wide rezoning was done to implement City Plan. This mistake will be corrected and the site will be placed within the H-M-N, High Density Mixed -Use Neighborhood zone district. A "dormintory" is permitted as an accessory use to the C.S.U. main campus, subject to review by the Planning Director or Hearing Officer. The minimum parking requirement is 350 cars. This standard may be modified. If a Modification of Standard is requested, the request must be forwarded to the Planning and Zoning Board as either a stand-alone request or consolidated into a Project Development Plan (P.D.P.) Or, if it can be demonstrated that the required number of spaces are provided off -site, then a Modification would not be necessary. 2. In the H-M-N zone, the maximum building height is five stories. The minimum setback from Pitkin Street is 30 feet. For all setbacks, building walls over 35 feet in height shall be set back an additional one foot beyond the minimum required, for each two feet or fraction thereof of wall or building that exceeds 35 feet in height. Terracing or stepping back the mass of large buildings is encouraged. For any structure over 40 feet, a special height review would be required in accordance with Section 3.5.1 of the Land Use Code. 3. Please note that in the H-M-N zone, under Section 4.24(E), new buildings shall provide doorways that face the street, at grade level or slightly elevated. In addition, the doorway facing the street shall be the principal entrance, with a sidewalk connection t the street. The layout of the building does not comply and a Modification of Standard would need to be submitted. COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. PO. Box580 Fort Collins, CO80522-0580 (970)221-6750 CURRENT PLANNING DEPARTMENT Community Planning and Environmental Services Current Planning City of Fort Collins October 10, 2002 Mr. Mathew Thompson Mewit Construction Company 7200 S. Alton Way, Bldg. A, Suite 300 Englewood, CO 80112 Dear Mr. Thompson: For your information, attached is a copy of the Staff's comments for the C.S.U. Student Housing Project — Main Campus which was presented before the Conceptual Review Team on October 10, 2002. The comments are offered by staff to assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to call me at 970-221-6750. Sincerely, Ted Shepard Chief Planner cc: Project Planner File 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020