HomeMy WebLinkAbout637 COWAN STREET - FDP - 21-03A - CORRESPONDENCE - (8)Department: Natural Resources Topic: General Number: 87 [10/13/04] No issues. Issue Contact: Doug Moore Created: 10/13/2004 Department: Water Wastewater Issue Contact: Jeff Hill Topic: Utility plan Number: 86 Created: 10/11/2004 [10/11/04] Provide the documentation for the 10 foot utility easement on the proposed sanitary sewer service and place the service centered in the utility easement. Permanent structures are not permitted with in the utility easement. See site, landscape and utility plans for other comments. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 84 Created: 9/21/2004 [9/21/04] 1 can't reference my previous comments because I did not receive any of the revised plans except 2 sheets for landscaping. Please provide the rest of the plans so I can review them. Topic: zoning Number: 7 Created: 6/25/2003 [9/21/04] 9-26-03 -1 don't see any dimensions etc noted for the proposed new building. 6-25-03 - Note building envelope, dimensions and distance to property lines on site plan. 9-21-04 - did not receive a site plan to re -review Number: 8 Created: 6/25/2003 [9/21/04] Add one more street tree along Cowan Number: 10 Created: 6/25/2003 [9/21/04] Show handicap ramps where sidewalk meets drive aisle or note that the walkway and drive aisle are at the same grade/elevation Number: 13 Created: 6/25/2003 [9/21/04] No parking lot landscaping is being shown Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Bob Barkeen Page 2 4--a City of Fort Collins BARRY SCHRAM P.O. BOX 270887 FT. COLLINS, CO 80527 STAFF PROJECT REVIEW Date: 10/29/2004 Staff has reviewed your submittal for 637 COWAN STREET PDP - AND FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Katie Moore Topic: General Number: 73 Created: 10/9/2003 [9/21/04] The legal description provided has an incorrect length for one side of the easement. Please revise. Also, the deed of dedication needs to be in the format used for Type II projects, with City Clerk acceptance (see attached). [5/4/04] A new legal description and sketch for the drainage easement was received, but the deed of dedication for the easement was not. Please contact me if you need a copy of the City's standard language again. [11/7/03] The blank easement dedication language was received, and redlines on it note the typos and language that needs to be changed. The sketch should not be an exhibit to the easement dedication. It would also be helpful to consolidate the pages instead of leaving so much empty space on each page. Recording fees are based on the number of pages being recorded. When consolidating, however, please retain a 1 ,x4" empty area on each page for the Larimer County Clerk and Recorder to use. Original comment: Please show the drainage easement on the overall utility plan and complete the necessary dedication paperwork (attached). The legal description must be supplied by a licensed surveyor in the state of Colorado, and the easement should accommodate any water from the ROW draining onto this property. Topic: Zoning Number: 85 Created: 9/21 /2004 [9/21/04] Please review Appendix E-6 of the LCLIASS, and revise all plans to meet the scanability requirements. Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 1 Created: 6/20/2003 [9/20/041 Developer will need to coordinate electric facilities with Light & Power Engineering. The electric meters will need to be near the N.W. corner of the new duplex. Number: 2 Created: 6/20/2003 [9/20/04] Light & Power Development Charges, plus electric system modification costs will be charged to the developer. Given the current information available, these costs will be about $8000.00. Page 1