HomeMy WebLinkAboutRAM'S CROSSING - PDP - 22-03 - CORRESPONDENCE - REVISIONS (3)2) Drainage Report
a) Please state the building foundation is slab -on -grade. This is noted on the plans, but not in the report.
S&A: First paragraph under Developed Site section.
b) On Page 1, please state this site is in the Canal Importation floodplain, not just the Canal Importation basin.
S&A: Added to page 1.
c) Please attach the Anderson report. It's referenced, but not attached.
S&A: Attached Anderson report
Department: Traffic Operations
Topic: Traffic
Number: 31
1111201031 No problems
S&A: Acknowledged.
Department: Water Wastewater
Topic: General
Number: 16
112/10/031
Issue Contact: Eric Bracke
Created- 1112012003
Issue Contact: Jeff Hill
Created. • 712812003
Additional fees may be assessed on this additional usage. Contact Mary Young for additional fee information
221-6700.
S&A: Acknowledged.
Number: 36 Created. • 1211012003
1121101031 Provide profiles of all proposed storm sewers.
S&A: See Sheets 5 & 6
Number: 37 Created: 1211012003
[121101031 Provide complete details for the adjustment of the existing sanitary sewer manhole
(see detail attached to plans).
S&A: See Sheet 6.
Redline drawings are available at the Current Planning front desk. Be sure and return all of your
redlined plans when you re -submit.
K you have any questions regarding these issues of any other issues related to this project,
please feel free to call me at (970) 221-6750.
Yours Truly,
Bob Barkeen
City Planner
Page 2
im am
RESPONSES FOR CITY COMMENTS
L'iatintia�rtL'nEi.ins By TAS and S&A
THE ARCHITECTS'STUDIO 12/15/2003 Date: 121,112003
CARR BIEKER
151 W. MOUNTAIN AVE.
FT. COLLINS, CO 80524
The Architect's Studio and Stewart & Assoc. have resonded to City Comments as follows:
Staff has reviewed your submittal for RAM'S CROSSING POP - TYPE I alIC/ AND FINAL PLAN,
and we offer the following comments:
ISSUES:
Department: Engineering
Topic: Engineering
Number: 32
112181031 No Problems
S&A: Acknowledged
Issue Contact: Dave Stringer
Created: 121812003
Department: Stormwater Utility Issue Contact: Wes Lamarque
Topic: Drainage
Number. 19 Created: 713112003
112/9/031
REPEAT COMMENT- There still needs to be a detail regarding the orifice plate and dimensions, as well as how it
is to be attached to the inlet.
Please provide details for the water quality outlet structures on the plans. An outlet structure similar to the City's
standard would be preferred. They can be a smaller version and would provide a better design regarding
aesthetics and space usage. An area inlet in the middle of the pond sticking out of the ground may be less
appealing visually.
S&A: Details for orifice plate added to Sheet No. 6.
Number. 33 Created: 121912003
There is a tree still being proposed on top of an area inlet as per previous comment. Please
relocate tree.
S&A: Tree has been relocated.
Topic: Erosion/Sediment Control
Number: 34 Created. 121912003
1. The plan has the wrong erosion control notes. Please use the "new" Loveland/Ft. Collins/Larimer County
notes for sediment and erosion control. Please add to these any notes specific to the construction of this
project.
S&A: Notes have been revised. See Sheet 6.
2. There is no erosion control plan that indicates the BMP's to be used and their location.
S&A: There are now. See Sheet 4.
3. There are no PS or EFF calculations.
S&A: Added PS & EFF to Storm Drainage Report.
Topic: Floodplain
Number: 35 Created.121912003
1) Sheet 2 of 6- Reference Map. Please change the note to add the word floodplain after Canal Importation Basin.
S&A: Added floodplain to Sheet 2 of 6.