HomeMy WebLinkAboutCITY OF FORT COLLINS VEHICLE STORAGE BUILDINGS - FDP - 23-03B - CORRESPONDENCE - (3)[6/3/04] See additional comments on relined plan sheets. Please return redlines plans with
next submittal
Department: Light & Power Issue Contact: Doug Martine
Topic: Light & Power
Number: 76 Created: 7/16/2004
[7/16/04] No comments
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Yours Truly,
Bob Barkeen
City Planner
Page 2
STAFF PROJECT REVIEW
Citvof Fort Collins
BHA DESIGN Date: 07/20/2004
RUSS LEE
4803 INNOVATION DR
FT. COLLINS, CO 80524
Staff has reviewed your submittal for CITY OF FTC VEHICLE STORAGE BUILDINGS PDP
- TYPE I AND FINAL PLAN, and we offer the following comments:
ISSUES:
Department: Engineering Issue Contact: Katie Moore
Topic: Civil plans
Number: 72 Created: 6/18/2004
[7/14/04] The offsite design needs a vertical curve - the grade break is over 1 % and the
maximum is 0.4%.
[6/18/04] Street design - C11 - The maximum grade break allowed is 0.4% and should be
met even when tying to existing grades.
Number: 75 Created: 7/14/2004
[7/14/04] Please work with Real Estate services to dedicate the easement for the water line
for the water district. Dedication of this easement will require Council approval.
Number: 77 Created: 7/16/2004
[7/16/04] The drainage alignment legals were checked for closure and are fine. The utility
and drainage easement on -site legal was checked and was fine. This item should be re-
named as an alignment or area (remove the word easement).
Department: Engineering Issue Contact: Dave Stringer
Topic: Civil plans
Number: 46 Created: 6/3/2004
[7/14/04] Please provide copies of these completed easements ASAP. The legals were
checked for closure and are fine.
[6/3/04] Need off -site easements for storm sewer work and any work out side of property.
Number: 49 Created: 6/3/2004
[7/14/04] The 10' radius curves provided are inadequate. Minimum 25' interior and 50'
exterior radii are required on emergency access easements. Please revise and resubmit
legals and re -name as an alignment (vs. easement).
[6/3/04] Need to dedicate emerengcy access easement by separate document and to
standard, with curves as opposed to 90-degree turns.
Number: 55 Created: 6/3/2004
[7/14/04] Repeat: How will under drain pipe tie into slope of pond, show detail.
[6/3104] Sheet C15 and C17 -How will under drainpipe tie into slope of pond, show detail,
Provide better detail of subdrain bedding and fabric system, fabric type, size of aggregate
and etc.
Number: 56
[7/14/04]
Created: 6/3/2004
Page 1