Loading...
HomeMy WebLinkAboutFIRST MAINSTREET BANK - PDP - 37-03 - REPORTS - RECOMMENDATION/REPORTFirst MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 13 The entire development plan is for 3 separate buildings (one bank and two office buildings) on a vacant 5.2 acre site located on the east side of Boardwalk Drive between East Harmony road and Whalers Way. There are pre -determined access points to the site from Boardwalk Drive and Whalers Way because of existing access drives to development across these streets or required separations between drives and streets. Because of the required location of the drive access into the site from Boardwalk it is infeasible to place Building A (the bank w/drive-thru) and Building B (future offices) side by side at the required "build -to" line setback (0 to 15') along Boardwalk Drive. Therefore, Building B has been located east of Building A, internal to the site. There is a direct pedestrian connection from main entry of Building B to the public sidewalk along Boardwalk Drive; however, there is the need for pedestrians to cross the bank's "exit" drive from its drive-thru facility. This crossing has been designed to be a constrained 14' wide drive with a 12' wide raised, enhanced walkway and a significant pedestrian plaza at the northwest corner of Building B. RECOMMENDATION: Staff recommends approval of the request for modifications of the standard located in Section 3.5.3(B)(1) - Orientation to a Connecting Walkway and the standard located in Section 3.5.3(B)(2) - Orientation to Build -to Lines for Streetfront Buildings ("build -to" line). Staff recommends approval of the First MainStreet Bank, Project Development Plan - #37-03. First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 12 Therefore, staff is recommending that the Administrative Hearing Officer approve the request for modifications to the standards set forth in Section 3.5.3(B)(1), and Section 3.5.3(B)(2), based on the criterion set forth in Section 2.8.2(H)(4) of the LUC. 5. Neighborhood Information Meeting The First MainStreet Bank, PDP contains proposed land uses that are permitted in the HC — Harmony Corridor Zoning District subject to an administrative (Type 1) review. The proposed uses are offices and financial services (bank). The LUC does not require that a neighborhood meeting be held for a Type I development proposal; however, two City -facilitated neighborhood meetings were held at the Spirit of Joy Lutheran Church (being in the neighborhood) to discuss this proposal. They occurred on October 9, 2003 and April 12, 2004. Copies of the notes taken at these two meetings are attached to the staff report. FINDINGS OF FACT/CONCLUSIONS After reviewing the First MainStreet Bank, PDP, staff makes the following findings of fact and conclusions: 1. The proposed land uses are permitted in the HC — Harmony Corridor District. 2. The PDP, containing defined primary land uses in the Harmony Corridor District, is in conformance with the policies of the Harmony Corridor Plan and Harmony Corridor Standards and Guidelines. 3. The Project Development Plan complies with all applicable district standards of Section 4.21 of the Land Use Code, HC Zoning District. 4. The Project Development Plan complies with the applicable General Development Standards contained in Article 3 of the Land Use Code, with the following exceptions: - The standard located in Section 3.5.3(B)(1) Orientation to a Connecting Walkway. - The standard located in Section 3.5.3(B)(2) Orientation to Build -to Lines for Streetfront Buildings ("build -to" line). First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 11 (3) by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or (4) the plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. City Staff Evaluation: Staff finds that the project as submitted, based on the land use, site layout, and its contextual compatibility with the surrounding land uses, is not detrimental to the public good; and, the plan as submitted will not diverge from the standards of the LUC except in a nominal, inconsequential way when considered from the perspective of the entire development plan. The entire development plan is for 3 separate buildings (one bank and two office buildings) on a vacant 5.2 acre site located on the east side of Boardwalk Drive between East Harmony road and Whalers Way. There are pre -determined access points to the site from Boardwalk Drive and Whalers Way because of existing access drives to development across these streets or required separations between drives and streets. Because of the required location of the drive access into the site from Boardwalk it is infeasible to place Building A (the bank w/drive-thru) and Building B (future offices) side by side at the required "build -to" line setback (0 to 15') along Boardwalk Drive. Therefore, Building B has been located east of Building A, internal to the site. There is a direct pedestrian connection from main entry of Building B to the public sidewalk along Boardwalk Drive; however, there is the need for pedestrians to cross the bank's "exit" drive from its drive-thru facility. This crossing has been designed to be a constrained 14' wide drive with a 12' wide raised, enhanced walkway and a significant pedestrian plaza at the northwest corner of Building B. First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 10 significantly. There is limited space between the bank and access drive making it impossible to place a building in that location and still make both buildings function efficiently. • The relationship of the bank on the site to parking lot is a necessary function of the facility. The building entrance needs to be adjacent to the parking lot for convenient access. The drive -through has to be on the east side of the building in order to function properly. • Although direct pedestrian connections are not possible for Building B, there will be a wide walkway and raised crosswalk where the pedestrian crosses the drive -through exit lane. This drive has also been narrowed down to fourteen feet, resulting in a shorter crossing for the pedestrian. There will also be a plaza located at the northwest corner of the building, emphasizing visual continuity and pedestrian scale, containing a raised planter and seat walls. • By locating the drive -through lane between building B and the berming along Harmony Road, the lane and car stacking is effectively hidden from public view. As specified in Section 2.8.2 Modification Review Procedures, (H) (Standards), the Administrative Hearing Officer may grant a modification standards only if it finds the granting of the modification would not be detrimental to the public good; and that: (1) the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested; or (2) the granting of a modification from the strict application of any standard would, without impairing the intent and purpose of this Land Use Code, substantially alleviate an existing, defined and described problem of city- wide concern or would result in a substantial benefit to the city by reason of the fact that the proposed project would substantially address an important community need specifically and expressly defined and described in the city's Comprehensive Plan, or in an adopted policy, ordinance or resolution of the City Council, and the strict application of such a standard would render the project practically infeasible; or First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 9 "Build -to lines based on a consistent relationship of buildings to the street sidewalk shall be established by development projects for new buildings ... in order to form visually continuous, pedestrian -oriented streetfronts with no vehicle use area between building faces and the street." and is further defined as: "Buildings shall be located no more than fifteen (15) feet from the right-of- way of adjoining street if the street is smaller than a full arterial or has on - street parking." MODIFICATION Building B is located on the east side of the bank building. The 12,600 square foot building will contain office uses and is designed to be complimentary in character with the bank and other buildings on the site. The drive -through lanes for the bank circulate entirely around Building B. Therefore the building does not have direct access to the public street sidewalks on either Boardwalk Drive or Harmony Road. Furthermore, the building is not located within fifteen feet from a street right-of-way. Due to the 80-foot Harmony Road setback requirement, it is impossible to meet the build -to line on Harmony Road. In addition, there are drive -through and functional requirements of the bank, which make the position of the building better situated in the southwest corner of the project. Since the private drive access onto Boardwalk is a fixed location, it is impossible to efficiently place Building B between the bank and the Boardwalk access. The request is for a modification to the Orientation to a Connecting Walkway Standard and the Orientation to Build -to Lines for Streetfront Buildings Standard for Building B. JUSTIFICATION A justification for this proposal relating to the Modification Criteria Section 2.8.2(H)(1) is that the proposed plan will serve the standard equally well or better than would a plan that strictly complies with the standard. We believe that the proposed project meets this criterion in the following ways: In order to meet the strict application of the code for the build -to line standard, Building B would have to be located on Boardwalk Drive. There are several reasons why this is not feasible or practical. If Building B is placed on the north side of the bank, the efficiency of the site is reduced First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 8 The rear of Building B is oriented to the East Harmony Road street frontage (a State highway, major arterial) and will be set back a distance of approximately 93' from the street right-of-way. As set forth in the City's adopted Harmony Corridor Standards and Guidelines, the building must maintain a minimum 80' separation from the "future" edge of pavement of Harmony Road. In this case, the proposed building will be set back 120' from existing (and future) edge of pavement, separated by berming and landscaping in the required Harmony Road setback. See item 4. Request for Modifications of Standards of the Staff Report (this page) for the Applicant's Request and Staffs Evaluation regarding modifications of these two standards. D. Division 3.6, Transportation and Circulation Section 3.6.4, Transportation Level of Service Requirements The proposal complies with the requirements set forth in Section 3.6.4(C) Transportation Impact Study. The applicant provided a Transportation Impact Study (TIS) to the City with the PDP submittal documentation. The City's Traffic Engineer has reviewed the TIS and has determined it to be acceptable. 4. Request for Modifications of Standards Applicant's Request: This request is for two modifications for Building B. Both modifications are for the "Relationship of Buildings to Streets, Walkways and Parking" requirements as outlined in the Fort Collins Land Use Code. The first modification being requested is from Section 3.5.3 (13)(1), Orientation to a Connecting Walkway. This regulation reads that: `At least one main entrance of any commercial or mixed -use building shall face and open directly onto a connecting walkway with pedestrian frontage." The second request is from Section 3.5.3 (13)(2), Orientation to Build -to Lines for Streetfront Buildings. This regulation reads that: First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 7 c. The proposal complies with the requirements set forth in Section 3.5.1(E) Building Materials. The building materials will consist of brick masonry veneer siding, sandstone veneer siding, cementitious wood siding, cementitious sidewall shingles, with brick and wood trim. The roofing will be a high profile asphalt shingle material. The colors will all be earthtone in nature. These materials and colors are present in the existing buildings in the surrounding area. 2. Section 3.5.3, Mixed -Use, Institutional and Commercial Buildings The proposal does not satisfy all Relationship of Buildings to Streets, Walkways and Parking standards, more specifically: a. Section 3.5.3(B)(1) Orientation to a Connecting Walkway states that: At least 1 main entrance of any commercial or mixed -use building shall face and open directly onto a connecting walkway with pedestrian frontage. The main entrance to Building B will be at the northwest corner of the building, facing the internal parking lot. It does open directly onto a connecting walkway with pedestrian frontage; however, pedestrians have to cross the 14' wide "exit" drive for the bank drive-thru to access the public sidewalk along Boardwalk Drive. b. Section 3.5.3(B)(2) Orientation to Build -to Lines for Streetfront Buildings states that: Build -to lines based on a consistent relationship of buildings to the street sidewalk shall be established by development projects for new buildings in order to form visually continuous, pedestrian - oriented streetfronts with no vehicular use area between building faces and the street. Building B will be set back from the ROW line for Boardwalk Drive a distance of 148, with a bank building in between. There will be a vehicular use drive (the bank's drive-thru "exit" drive) between the building entry and the public sidewalk along the east side of Boardwalk Drive. There will be a raised and enhanced pedestrian walk across the bank's "exit" drive from the building entrance to the public sidewalk. First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 6 The proposal complies with the design standards, requirements, and specifications for the services as set forth in this section. C. Division 3.5, Building Standards 1. Section 3.5.1, Building and Project Compatibility a. The proposal complies with the requirements set forth in Section 3.5.1(B) Architectural Character. This development is adjacent to an existing office park to the north, existing single-family residential to the east, existing commercial and multi -family residential to the west, and a regional shopping center to the south. The building design and massing proportions for the 3 buildings reflects a complementary and compatible style with that of the existing commercial, office, residential, and retail uses that surround this property. b. The proposal complies with the requirements set forth in Section 3.5.1(C) Building Size, Height, Bulk, Mass, Scale. • Building A - the bank building will contain a total of 11,300 square feet of floor area on two floors. There are a series of hipped and gabled rooflines, with slopes at a pitch of 1 foot of rise in 2 horizontal feet and 1 foot of rise in 3 horizontal feet. The overall height of the building is 36'-10", which is about the same height as or slightly taller than the two-story and three-story buildings on three sides of this property. • Building B - this office building will contain a total of 12,600 square feet of floor area on two floors. There are a series of hipped and gabled rooflines, with slopes at a pitch of 1 foot of rise in 2 horizontal feet. The overall height of the building is 31'-11", which is comparable to the height of the two-story and three-story buildings on three sides of this property. • Building C - this office building will contain a total of 22,000 square feet of floor area on two floors. There are a series of hipped and gabled rooflines, with slopes at a pitch of 1 foot of rise in 3 horizontal feet. The overall height of the building is 31'-6", which is comparable to the height of the two-story and three-story buildings on three sides of this property. First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 5 2. Section 3.2.2, Access, Circulation and Parking a. The proposal complies with Section 3.2.2(C)(4)(a) in that it provides adequate, secure, and convenient bicycle parking located near the entrance to the buildings. There will be three bike parking spaces (with racks), one near the entrance to each building. The racks will accommodate 15 bicycle parking spaces, which exceeds the minimum of 11 spaces required. b. The proposal complies with Section 3.2.2(C)(5)(a) in that it provides direct, safe, and continuous walkways and bicycle connections to major pedestrian and bicycle destinations in the surrounding area. c. The proposal complies with Sections 3.2.2(D)(1) & (2) in that it provides for pedestrian and vehicle separation, to the maximum extent feasible, via direct walkways from the Boardwalk Drive and Whalers Way street sidewalks to the building entrances and a protected walkway through the parking lot between the north and the two south buildings on -site; and, it provides unobstructed vehicular access between the public streets (Boardwalk Drive and Whalers Way) and the off-street parking spaces. d. The proposal complies with Section 3.2.2(K)(2)(a) in that the project will provide parking at a ratio of 2.83 spaces per 1,000 square feet of leasable floor area for the proposed office uses and 3.45 spaces per 1,000 square feet of financial service (bank) use. Neither exceeds the maximum parking allowance of 3.0 spaces per 1,000 square feet of floor area for office uses or 3.5 spaces per 1,000 square feet of floor area for a financial service use. The bank building will contain 11,300 square feet of floor area and the two office buildings will contain a total of 34,600 square feet of floor area. There will be 137 parking spaces on -site, 98 for the office buildings and 39 for the bank building. e. The proposal complies with Section 3.2.2(K)(5) in that it provides 7 handicapped parking spaces (of the tota► of 137 spaces on -site) with accessible ramps directly in front of the buildings. The minimum number of handicapped spaces required would be 5. B. Division 3.3, Engineering Standards 1. Section 3.3.5, Engineering Design Standards First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 4 3. Article 3 of the Land Use Code — General Development Standards The Project Development Plan complies with all applicable General Development Standards, more specifically as follows: A. Division 3.2, Site Planning and Design Standards 1. Section 3.2.1, Landscaping and Tree Protection a. The proposal complies with Section 3.2.1(D)(1)(c) in that it provides "full tree stocking" within 50' of the new buildings, according to the standards set forth in this section. b. The proposal complies with Sections 3.2.1(D)(2)(a) & (b) in that canopy shade (street) trees are provided at a 35' - 40' spacing in the 10' - 20' wide landscape parkway along Boardwalk Drive (where possible) and 7' behind the attached sidewalk along Whalers Way. The ultimate curb location along Boardwalk Drive will be approximately 9' to the east of its location on the current development plans; therefore, shade trees are being placed behind the sidewalk along the parking lot for Building A and adjacent to Building C. c. The proposal complies with Section 3.2.1(D)(3) in that no one species of the proposed 123 new trees on the development plan will exceed 15% of the total trees on -site. d. The proposal complies with Section 3.2.1(E)(4)(a) in that trees are being provided at a ratio of 1 tree per 25 lineal feet along Boardwalk Drive adjacent to the parking lot. e. The proposal complies with Section 3.2.1(E)(4)(b) in that the on -site parking area will be screened from Boardwalk Drive to the west with deciduous shrub plantings that will block at least 75% of the vehicle headlights and extend along at least 70% of the street frontage along the parking area. f. The proposal complies with Section 3.2.1(E)(5) in that it provides 11.5% interior landscaping in the parking area (containing more than 100 parking spaces), satisfying the minimum requirement of 10%. First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 3 2. Division 4.21 of the Land Use Code — Harmony Corridor District The proposed office and financial service (bank) uses are permitted in the HC Zoning District subject to an administrative review. The proposed uses are defined as Primary Uses in this district. The PDP meets the applicable Land Use Standards, more specifically: 1. Section 4.21(D)(1) Harmony Corridor Land Use Standards. This development proposal complies with the Harmony Corridor land use and locational standards as adopted by the City and is in conformance with the policies of the Harmony Corridor Plan. 2. Section 4.21(D)(3) Dimensional Standards. As set forth in Section 4.21(D)(3)(a), the maximum building height for all non-residential uses shall be 6 stories. All 3 of the proposed buildings in the First MainStreet Bank, PDP will be two stories in height, not exceeding 37'. The PDP meets the applicable Development Standards, more specifically: 1. Section 4.21(E)(1) Harmony Corridor Development Standards. This development proposal complies with the Harmony Corridor design standards as adopted by the City and is in conformance with the policies of the Harmony Corridor Standards and Guidelines. 2. Section 4.21(E)(2) Site Design. The 3 buildings in the First MainStreet Bank, PDP will be two stories in height, each containing from 11,000 square feet to 22,000 square feet of gross leasable floor area. The buildings will be residential in character and will be set back between 100' and 200' from the single-family residential neighborhood to the east, with earthen berming and landscaping in the setback areas. This development will not present a drastic and abrupt change in scale and height of buildings from those in the surrounding areas (office park, commercial/retail, shopping center, single-family & multi -family residential), as set forth in Section 4.21(E)(2)(b). First MainStreet Bank, PDP - #37-03 June 28, 2004 Administrative Hearing Page 2 the standard located in Section 3.5.3(B)(2) - Orientation to Build -to Lines for Streetfront Buildings ("build -to" line). A request for a modification to the standard has been submitted for consideration; and, standards located in Division 4.21 Harmony Corridor (HC) of ARTICLE 4 — DISTRICTS. Offices and financial services (banks), defined as Primary Uses, are permitted in the HC — Harmony Corridor Zoning District, subject to an administrative (Type 1) review. The purpose of the HC District is: "..... to implement the design concepts and land use vision of the Harmony Corridor Plan -- that of creating an attractive and complete mixed -use area with a major employment base." This proposal complies with the purpose of the HC District as it provides permitted primary uses in a development plan in an area identified as a "Basic Industrial and Non - Retail Employment Activity Center" in the Harmony Corridor Plan. This proposed new development will be on a vacant parcel of land and will tie into and utilize existing roadways (Boardwalk Drive and Whalers Way), utilities, and services in the area. COMMENTS: Background The surrounding zoning and land uses are as follows: N: MMN; existing office park (Boardwalk) S: HC; existing shopping center (Harmony Market) E: RL; existing single-family residential (Mallards @ The Landings) W: MMN; existing convenience store, daycare, multi -family residential (7-11, Little People's Landing, Pier Condominiums) The property was annexed into the City in September, 1977 as part of the Landings First Annexation. The property was platted as Rafferty's P.U.D. in August, 1995. At that time a development plan for a 6,600 square foot sit-down restaurant, with associated parking and driveways, on approximately 1/2 of the 5.2 acre site was approved by the Planning and Zoning Board. ITEM NO. ~� MEETING DATE 2 O STAFF Citv of Fort Collins HEARING OFFICER STAFF REPORT PROJECT: First MainStreet Bank, Project Development Plan - #37-03 APPLICANT: VF Ripley Associates, Inc. c/o Cathy Mathis 401 West Mountain Avenue, Suite 201 Fort Collins, CO. 80521 OWNER: First MainStreet Bank, N.A. 401 Main Street Longmont, CO. 80501 PROJECT DESCRIPTION: This is a request for bank & office uses on a vacant 5.2 acre parcel of land. The development will contain 3 two-story buildings, between 31' and 37' in height, with a total of 45,900 square feet of leasable floor area. The property is located at the northeast corner of East Harmony Road and Boardwalk Drive. It is in the HC — Harmony Corridor Zoning District. RECOMMENDATION: Approval EXECUTIVE SUMMARY: This Project Development Plan (PDP) complies with the applicable requirements of the Land Use Code (LUC), more specifically: the process located in Division 2.2 - Common Development Review Procedures for Development Applications of ARTICLE 2 - ADMINISTRATION; standards located in Division 3.2 - Site Planning and Design Standards, Division 3.3 - Engineering Standards, Division 3.5 - Building Standards, and Division 3.6 - Transportation and Circulation of ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS, with the following exceptions: the standard located in Section 3.5.3(B)(1) - Orientation to a Connecting Walkway. A request for a modification to the standard has been submitted for consideration; COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750 PLANNING DEPARTMENT