Loading...
HomeMy WebLinkAboutCINGULAR, TAFT HILL & ELIZABETH (CEDARWOOD PLAZA) WTF - PDP - 31-03A - CORRESPONDENCE -[9/12/05] Please provide a landscape plan showing existing landscaping and proposed landscaping to screen the equipment structure. Number: 3 Created: 9/12/2005 [9/12/05] Review code section 3.8.13 for wireless telecommunication requirements If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Anne H. Aspen City Planner Page 3 neighbors. The lighting must be fully shielded and fully down -directional. Please contact me if you have questions. Department: Engineering Topic: General Number: 16 [9/23/05] No comments. Issue Contact: Sheri Wamhoff Created: 9/23/2005 Department: Light & Power Issue Contact: Alan Rutz Topic: General Number: 4 Created: 9/19/2005 [9/19/05] Electric meter must be located on the outside of the equipment fence. Show the meter location on your detail sheets. Number: 5 Created: 9/19/2005 [9/19/05] Provide an overall site plan to show where this proposal is located within the shopping center. Number: 6 Created: 9/19/2005 [9/19/05] Locate existing electric lines. Show underground electric lines on the site plan and civil survey plan. Number: 7 Created: 9/19/2005 [9/19/05] Contact Light and Power as soon as possible with load requirements. Comments on any charges or system modification costs will be made after load requirements are determined. Department: Natural Resources Topic: General Number: 12 [9/21/05] No issues. Department: Transportation Planning Topic: General Number: 13 [9/21/05] No comments Issue Contact: Doug Moore Created: 9/21 /2005 Issue Contact: Kurt Ravenschlag Created: 9/21 /2005 Department: Water Wastewater Issue Contact: Roger Buffington Topic: General Number: 15 Created: 9/21 /2005 [9/21/05] There is a water main and a sanitary sewer that extend west from Taft on the south side of the Farmers Table and behind the buildings to the northwest. Field locate these lines and show on the site plan so that potential conflicts (if any) can be identified. Department: Zoning Issue Contact: Jenny Nuckols Topic: ZONING Number: 1 Created: 9/12/2005 [9/12/05] 1 would like to see an overall site plan of this shopping center - I am not sure of the placement of the pole and equipment shelter based on the info provided. Number: 2 Created: 9/12/2005 Page 2 C STAFF PROJECT REVIEW cle� of Fotc cou�ns MATZKO CONSULTING Date: 09/26/2005 MICHAEL MATZKO PO BOX 3600 AVON, CO 81620 Staff has reviewed your submittal for CINGULAR, TAFT AND ELIZABETH (CEDARWOOD PLAZA) WTF - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Anne Aspen Topic: General Number: 14 Created: 9/21 /2005 [9/21/05] Staff is concerned about the visibility of this tower from Taft Hill Road and the neighborhood to the south of the shopping mall. Please show other possible locations and tower configurations that will reduce the visibility of this equipment: can you locate on top of the existing roof? Can you use equipment that is less visually intrusive? Can you locate somewhere else on the site that would have fewer impacts to the surroundings? We have several good examples here in Fort Collins that better achieve compatibility. Please let me know if you would like pictures of these. Number: 8 Created: 9/20/2005 [9/20/05] The Building Inspection Department requires a pre -submittal Code Review Meeting for all projects. This project must meet the UBC and the2005 National Electrical Code. Plans Analyst Rick Lee advises you to be aware that Fort Collins is a high wind location (100 mph) so the mounting devices need to be designed to satisfy this requirement. A scan of their comments will be emailed along with your staff review comment letter. Number: 9 Created: 9/20/2005 [9/20/05] As mentioned by other reviewers below, the overall site plan is not particularly clear. Please revise this drawing to clearly show the property boundaries (label them) and the entire existing building footprint (use proper line weights) of the shopping center. You should also show the neighboring footprints to the south and southeast and indicate whether they are commercial or residential so we can evaluate any impacts to these abutting properties. Number: 10 Created: 9/20/2005 [9/20/05] Per the Land Use Code, you must provide a foot of setback from the nearest property line for every foot of height for a monopole assembly unless you demonstrate to the Director of Current Planning that the structure would collapse not topple. It appears that you may have already met the setback requirement. This will be confirmed once you have labeled the property line. Number: 11 Created: 9/20/2005 [9/20/05] If the facility remains in the proposed location or in the existing access drive aisle behind the shopping center, it seems advisable to add some very discreet security lighting or reflective signage so that vehicles will see the new structure. If the adjacent use to the south are residential, the design of this lighting will need to be very sensitive to these Page 1