HomeMy WebLinkAboutADRIAN SUBDIVISION, 1ST FILING - PDP - 42-03A - CORRESPONDENCE - FIRE AUTHORITY REQUIREMENTSNOTE: When any portion of the facility or any portion of an exterior wall of the first story of
the building is located more then 150 feet from fire apparatus access as measured by an
approved route around the exterior of the building or facility it shall be fire sprinklered. 1997
UFC 902.2.1
Number: 87 Created: 8/6/2004
[1/3/05]
[8/6/04] STREET NAMES:
Street names shall be verified and reviewed by County / City Planning Dept. prior to being
put in service. 1997 UFC 901.4.5
Page 2
--� Project Comments Sheet
of Fort Collins
Selected Departments
Department: PFA
Date: January 3, 2005
Project: ADRIAN SUBDIVISION, 1ST FILING PDP/FC - #42-03A/C
All comments must be received by Steve Olt in Current Planning, no later than the
staff review meeting:
December 08, 2004
Note - Please identify your redlines for future reference
Issue Contact: Michael Chavez
Topic: Utilities
Number: 83 Created: 8/6/2004
[ 1 /3/05]
[8/6/04] PRIVATE DRIVE OR PRIVATE STREET?
A private drive may serve up to 4 isolated single family lots as set forth in Section
3.6.2(L)(1)(b) of the LCLUC. This appears to support 7 lots and would not fall under a
private drive. Which direction (street) do the lots face?
Number: 84 Created: 8/6/2004
[ 1 /3/05]
[8/6/04] PREMISES IDENTIFICATION: Approved numerals or addresses shall be provided
- for all new and existing building in such a position as to be plainly visible and legible from
the street or road fronting the property. 1997 UFC 901.4.4
Number: 85 Created: 8/6/2004
[1/3/05]
[8/6/04] WATER SUPPLY: Residential (Within GMA)
No Residential building can be greater then 400 feet from a fire hydrant.
Fire hydrants are required with a maximum spacing of 800 feet along an approved roadway.
Each hydrant must be capable of delivering 1000 gallons of water per minute at a residual
pressure of 20 psi. 1997 UFC 901.2.2.2
Number: 86 Created: 8/6/2004
[1/3/05]
[8/6/04] REQUIRED ACCESS:
A fire lane is required. The fire lane shall be visible by painting and signage, and maintained
unobstructed. 1997 UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1-1 FCLUC
Signature Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report Other_
Utility Redline Utility Landscape
Page 1
Steve Olt - Adrian Subdivision - PFA c, rents _ Page 1 ji
From: Steve Olt
To: Gregory Byrne
Date: 1/3/05 2:31 PM
Subject: Adrian Subdivision - PFA comments
Greg,
Attached are the comments received from Michael Chavez of PFA regarding the Adrian Subdivision, First
Filing - PDP. They were entered into DMS by Michael on August 6, 2004, during the normal course of
development review.
There is no signed memo from PFA in the project file. They typically do not provide a formal sign -off on,
projects during developlllent review and, to my knowledge, have not done so in this case.
Please let me know if and how I can further assist on this matter.
Steve
CC: Cameron Gloss; Patty Storm; Paul Eckman; Tom Vosburg
Steve Olt -Fwd: PFA Memo m Page 1
From:
Gregory Byrne
To:
Cameron Gloss; Steve Olt
Date:
1 /3/05 11:03AM
Subject:
Fwd: PFA Memo
Steve, do we have the notes from Ron G.?
Greg
>>> City Manager's Office 01/03/05 10:55AM >>>
Hi Greg and John:
Greg, per Tom's suggestion below, would your office have a copy of the memo that David refers to below?
I have also included John Mulligan on this email in case his office is the record -keeper of the requested
memor. As the Adrian Annexation goes to Council tomorrow night, we will most likely want to include the
memo in Council's read -before packets tomorrow. Please let me know!
Thank you,
Kelly Courkamp
x6509 _
>>> Tom Vosburg 01/03/05 09:04AM >>>
Kelly -
Perhaps CPES has this, since they are coordinating the annexation.
Please track as an SAR
Tom
>>> David Roy 01/02/2005 5:04:38 PM >>>
Good evening;
could we please have a copy of the memo from the Poudre Fire Authority signing off on the safety of the
Private Drive proposed for the Adrian development?
Thank you.
David
CC: patty storm