HomeMy WebLinkAboutRICKARDS SUBDIVISION, 630 S. WASHINGTON - 5-04 - CORRESPONDENCE -Department: Police Issue Contact: Joseph Gerdom Topic: General Number: 12 Created: 2/19/2004 [2119/04] Alley housing needs clear addressing. Should be visible from BOTH alley and street. Department: Stormwater Utility Issue Contact: Basil Harridan Topic: Drainage Number: 8 Created: 2/12/2004 [2/12/041 Prior to any building permit being allowed on the newly created lot a grading drainage and erosion control plan should be prepared showing how the site would drain. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 7 Created: 2/9/2004 [2/9/04] Provide a utility plan which shows and labels all existing as well as proposed water and sewer lines. Provide all standard general notes and details on the utility plan. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 2 Created: 2/4/2004 [2/4/04] No comments Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Bob Barkeen City Planner Page 2 STAFF PROJECT REVIEW Citvof Fort Collins r I KARL ZELLER Date: 02/24/2004 1575 E. CR 66 WELLINGTON, CO 80549 Staff has reviewed your submittal for RICKARDS SUBDIVISION - 630 S. WASHINGTON - TYPE I, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Dave Stringer Topic: General Number: 11 Created: 2/17/2004 (2/17/04] Additional comments will be provided when this project is submitted as a PDP/Building Permit Review Topic: Plat Number: 9 Created: 2/17/2004 [2/17/04] Need to provide an 8 feet utility easement along back property line along alley as per Larimer County Urban Area Street Standards detail 7-12F Number: 10 Created: 2/17/2004 [2/17/04] " Approved as to Form" Change from Director of Engineering to City Engineer Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 1 Created: 2/2/2004 [2/2/04] No comments. Department: Natural Resources Topic: General Number: 6 [2/6/04] No issues. Issue Contact: Doug Moore Created: 2/6/2004 Department: PFA Issue Contact: Michael Chavez Topic: General Number: 3 Created: 2/6/2004 [216/04] Water Supply: No residential building can be greater than 400 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 800 feet along an approved roadway. Each hydrant must be capable of delivering 1,000 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Number: 4 Created: 2/6/2004 [2/6/04] Sprinkler Requirements: This proposed building shall be fire sprinklered. When any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility, it shall be fire sprinklered. Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. 1997 UFC 1003.2.9; 902.2.1 Number: 5 Created: 2/6/2004 [2/6/04] Address Numerals: Address numerals shall be visible from the street fronting the property, and posted with a minimum 6-inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable.) Note: Address visible from the alley shall include numerals and street name (Washington Street). 1997 UFC 901.4.4 Page I