Loading...
HomeMy WebLinkAboutCDOT POUDRE RIVER REST AREA - SITE PLAN ADVISORY REVIEW - 27-04 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTi �+ •tit a y � q J r1-. • 1 • � y L 1• � ` �• _ f�' _ '•4?,�t- � r`'. :ice 7 i farr .N T M az. ZEST nEA PRC FFa7�- i vi�F�tHAcFD+ BY THE CITY L II'J� i i1r0 T o\LRMS NATURA'l \ _S�J' RC E, REf�'.4iRTf�iEIi.;ITerc�rtL� - — 1 ` \ 1 ,,r r ~• .. fir, - / . ( .%-�9' � * '' .� .r r _���.- \._ � � �� _�y} _ �..!!`�':'- '' it ii� �•;' Poudre River Rest Area CDOT City of Fort Collins Drainage and Erosion Control Plan (30%Submittal) SECTION 1 - GENERAL LOCATION AND DESCRIPTION LOCATION The Poudre River Rest Area site can be described as situated in the northeast quarter of Section 21, Township 7 North, Range 68 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado and compromises approximately 16 acres. The project location map, Figure 1.1, is illustrated on page two. The Poudre River Rest Area is located to the south of the existing City of Fort Collins Welcome Center and Environmental Learning Center (ELC), just west of the Interstate 25 frontage road. The site is adjacent to Boxelder Creek, with easterly portions of the proposed site within the Boxelder Creek Floodplain. The proposed rest area site is located directly west of Boxelder Creek. The site is also bound to the west and south by undeveloped land. The site is located within the Poudre River Basin. DISCRIPTION OF PROPERY The proposed project, approximately 16 acres, is to build a Colorado Department of Transportation (CDOT) rest area, which will replace the existing two rest areas located along 1-25, just north of the Harmony Road interchange in Fort Collins. This proposed project site is to be used for non-residential use. The rest area is a 2659 sq. foot building, which will contain men and women's restrooms, two family rstrooms, a lobby, and an equipment storage area. Future plans for the site will include a visitor's center, which is currently located at the Welcome Center to the north. The proposed finished slab on grade floor will be at 4856 feet which is 1.5 feet above the recorded City of Fort Collins' BFEs. A separate garage will be located at the south end of the site. The garage will house maintenance equipment and supplies. The site is relatively flat and is generally 5-8' in elevation above the flowline of Boxelder Creek. The exiting site sheet drains from the north to the south at approximately 1 %. See figure 1.1. Stantec 1 JULY 2004 Poudre River Rest Area City of Fort Collins CDOT Drainage and Erosion Control Plan (30% Submittal) LIST OF TABLES Table 2.1 - Exsiting Drainage Basins............................................................................................................6 Table 2.2 - Proposed Drainage Bains..........................................................................................................6 Table 5.1 - Detention Pond Summary .........................................................................................................13 Table5.2 - Water Quality Summary ............................................................................................................13 Table5.3 - Inlet Summary ..........................................................................................................................15 LIST OF FIGURES Figure1.1 - Vicinity Map................................................................................................................................2 Figure 1.2 - Proposed Poudre River Rest Area...........................................................................................3 Figure 2.1 - Existing Drainage Baisns...........................................................................................................8 Figure 2.2 - Proposed Drainage Basins........................................................................................................9 APPENDICES APPENDIX A — VICINITY MAP APPENDIX B — HYDROLOGY APPENDIX C — STREET CAPACITY APPENDIX D — PRELIMINARY DETENTION POND DESIGN APPENDIX E — PRELIMINARY INLET SIZING APPENDIX F — PRELIMINARY PIPE DESIGN APPENDIX G — PRELIMINARY RIPRAP SIZING APPENDIX H — WATER QUALITY GRASS SWALE APPENDIX I — DRAINAGE AND EROSION CONTROL PLANS Stantec ii July 2004 Poudre River Rest Area City of Fort Collins CDOT Drainage and Erosion Control Plan (30% Submittal) TABLE OF CONTENTS SECTION 1 - GENERAL LOCATION AND DESCRIPTION...........................................1 LOCATION...............................................................................................................................................1 DISCRIPTIONOF PROPERY.................................................................................................................1 DRAINAGECONCEPT............................................................................................................................4 DRAINAGECONCEPT............................................................................................................................4 SECTION2 - DRAINAGE BASINS................................................................................5 MAJORBASIN DESCRIPTION...............................................................................................................5 SUB- BASIN DESCRIPTION...................................................................................................................5 SECTION 3 - DRAINAGE DESIGN CRITERIA..............................................................9 REGULATIONS........................................................................................................................................9 HYDROLOGICCRITERIA.......................................................................................................................9 HYDRAULICCRITERIA...........................................................................................................................9 VARIANCIs...............................................................................................................................................9 SECTION 4 - DRAINAGE FACILITY DESIGN.............................................................10 GENERALCONCEPT...........................................................................................................................10 SPECIFICDETAILS...............................................................................................................................10 STORMWATERQUALITY.....................................................................................................................11 STORMSEWER DESIGN.....................................................................................................................13 SECTION5 - EROSION CONTROL.............................................................................15 GENERALCONCEPT...........................................................................................................................15 SPECIFICDETAILS...............................................................................................................................15 SECTION6 - CONCLUSIONS......................................................................................16 COMPLIANCEWITH STANDARDS......................................................................................................16 DRAINAGECONCEPT..........................................................................................................................16 STORMWATERQUALITY CONCEPT..................................................................................................16 EROSIONCONTROL CONCEPT.........................................................................................................16 SECTION7 - REFERENCES........................................................................................I i Stantec i July 2004 Poudre River Rest Area Drainage Report (30% Submittal) July 9, 2004 Completed for: or Colorado Department of Transportation Submitted to: City of Fort Collins Sear -Brown Projects 813-005, 813-007 Stantec Projects 181700038 0 Stantec Consulting, Inc. 209 S. Meldrum Fort Collins, Colorado 80521 970-482-5922 tel 970-482-6368 fx Stantec