HomeMy WebLinkAbout1310 LAPORTE AVE., MCKINLEY COTTAGES SUBDIVISION - FDP - 35-04B - CORRESPONDENCE -Number: 79 Created: 10/25/2005
[10/25/05] Finish grade elevations must be provided for all streets, lot comers, finish floor/
top of foundations of buildings (existing) for all lots.
Department: Light & Power
Topic: General
Number: 32
[9/29/05]
[7/1/05] No comments.
Department: Natural Resources
Topic: General
Number: 58
[10/13/05] No issues.
Issue Contact: Doug Martine
Created: 7/1 /2005
Issue Contact: Doug Moore
Created: 10/13/2005
Department: Transportation Planning Issue Contact: Kurt Ravenschlag
Topic: Plat
Number: 93 Created: 10/25/2005
[10/25/05] Label and dimension all easements, sidewalks, parkways, and ROW on overall
utility plan.
Department: Water Utilities Issue Contact: Wes Lamarque
Topic: Drainage
Number: 50 Created: 7/15/2005
[10/28/05] Please include the note on the grading plan regarding the allowed impervious
area per lot on the plat and site plan.
[7/15/05] Please show on the grading plan the amount of impervious area for each lot per
drainage report calculations. The plat should only have a note referencing the grading plan.
Number: 95 Created: 10/28/2005
[10/28/05] Please provide a flow calculation for the swale along the east property boundary.
The swale needs to carry 1.33 times the 100-year flow.
Department: Water Utilities Issue Contact: Roger Buffington
Topic: Utility Plan
Number: 76 Created: 10/25/2005
[10/25/05] Show location of gas and electric to identify potential conflicts with curb stop
locations.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
4 h Le. Aspen
City Planner
Page 4
Topic: label
Number: 61 Created: 10/21 /2005
[10/21/05] Dimensions are still not shown on the overall utility plan for sidewalks,
easements, and ROW. Label actual dimensions of ROW for the alley so that limits of paving
are entirely clear.
Number: 63 Created: 10/21 /2005
[10/21/05] Label and dimension all easements on all plans, including Sight distance
easement. Easements should match exactly as shown on the plat.
Number: 64 Created: 10/21 /2005
[10/21/05] Label surrounding structures on ALL sheets
Number: 77 Created: 10/25/2005
[10/25/05] The current date (month and year) should be shown under the legal description
(plat and plans).
Number: 80 Created: 10/25/2005
[10/25/05] Sidewalks are not labeled or dimensioned.
Number: 83 Created: 10/25/2005
[10/25/05]Label curb return radii (must conform w/ Table 8-2)
Number: 84 Created: 10/25/2005
[10/25/05] Please label Portland cement concrete to back of ROW for all access/driveway
approaches.
Number: 85 Created: 10/25/2005
[10/25/05] Label the existing 6' wide crosspan along LaPorte
Topic: Plat
Number: 90 Created: 10/25/2005
[10/25/05] Provide the reception # for ROW dedication from Reclamation Village in the
Alley.
Number: 91 Created: 10/25/2005
[10/25/05] please include dimension arrows for boundaries on easements.
Number: 92 Created: 10/25/2005
[10/25/05] More clarification is needed regarding the private access easements= provide a
note with who is to maintain, and who it is for.
Number: 94 Created: 10/26/2005
[10/26/05] Include the following standard drawings from LCUASS: 701-(for replacement of
curb cut and of damaged sections if necessary) 1601, 1602, 1403.
Topic: Utility Plan
Number: 78 Created: 10/25/2005
[10/25/05] Provide a typical section for the paved alley and sections for each street with
new/widened sidewalk showing dimensions and labels. For the alley, and sidewalks- please
show the crossslopes on the sections.
Page 3
Number: 69 Created: 10/21/2005
[10/21/05] The sidewalk transition from detached on your property to attached to the east
must be smoother. Angular changes are not pedestrian friendly.
Number: 71 Created: 10/21 /2005
[10/21/05] The proposed sight distance easement is not shown on all plans. Please update
all sheets.
Number: 72 Created: 10/21 /2005
[10/21/05] Are spot elevations shown on the Plan and Profile sheets existing or proposed?
Several spot elevations also do not have descriptive abbreviations. More elevations are
required to ensure that cross slopes are adequate. At minimum, we need to see the
elevations along the north edge of paving (existing and proposed).
Number: 73 Created: 10/21 /2005
[10/21/05] Provide a typical cross section for the alley. Also, provide cross sections for the
streets where new sidewalks are proposed.
Number: 74 Created: 10/21 /2005
[10/21/05] See redlines for additional minor comments.
Number: 75 Created: 10/25/2005
[10/25/05] There is a dip in the south flowline (presumably where the swale begins). If the
dip is in a large portion of the street section, a crosspan should be provided to increase
durability of the alley, and to promote drainage into your swale.
Number: 81 Created: 10/25/2005
[10/25/05] No crosswalks are shown on the plans. Please revise per city standards.
Number: 82 Created: 10/25/2005
[10/25/05] Where your new curb cut is proposed, spot elevations are required to ensure that
minimum flowline grades are met.
Number: 86 Created: 10/25/2005
[10/25/05] List the variance for the sight distance easement in the general notes #48.
Number: 87 Created: 10/25/2005
[10/25/05] Linetypes should be solid for proposed and ghosted or dashed for existing
features.
Number: 88 Created: 10/25/2005
[10/25/05] The City signature block should be 3.5" high by 4.5" long.
Number: 89 Created: 10/25/2005
[10/25/05] All symbols must be included in a legend for both existing and proposed
features. Legend does not have to be on each sheet but must include all symbols and
linetypes.
Page 2
STAFF PROJECT REVIEW
Cityof Fort Collins
M TORGERSON ARCHITECTS Date: 10/28/2005
MIKAL TORGERSON
223 N COLLEGE AVE
FORT COLLINS, CO 80524
Staff has reviewed your submittal for 1310 LAPORTE AVE, MCKINLEY COTTAGES
SUBDIVISION PDP, TYPE I AND FINAL PLANS, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Anne Aspen -
Topic: General
Number: 56 Created: 10/12/2005
[10/12/05] The following departments have indicated that they do not have comments or
concerns at this time: Comcast, County Assessor, Park Planning, Zoning, Xcel and Post
Office.
Number: 57 Created: 10/12/2005
[10/12/05] No further comments.
Department: Engineering Issue Contact: Dan DeLaughter
Topic: format
Number: 65 Created: 10/21/2005
[10/21/05] - Still some scanability issues on the grading and erosion control plan- see
redlines.
Number: 70 Created: 10/21 /2005
[10/21/05] When referring to details, please refer to specific detail numbers and speck
sheets (as opposed to describing the detail). Please number your details accordingly.
Topic: General
Number: 60 Created: 10/21 /2005
[10/21/05] Provide a reference to the current soils investigation report on your cover sheet
(title, author).
Number: 62 Created: 10/21 /2005
[10/21/05] Please provide our standard street cut note on both overall utility and grading
sheets: "Limits of street cut are approximate. Final limits to be determined in the field by the
City Engineering Inspector. All repairs to be in accordance with City street repair standards."
Reference the note where street cuts are shown.
Number: 66 Created: 10/21 /2005
[10/21/05] The driveway leading into the alley should be flared according to Detail 1 in Fig.
7.12F. This detail requires 6' by 8' flares on both sides with the same material as the
driveway. We'll need a detail to see how this will work with your drainage swale on the east
side.
Page 1