HomeMy WebLinkAbout2337 S. SHIELDS ST., HOME STATE BANK - PDP - 8-05 - CORRESPONDENCE -PROJECT VI C I N i i Y MAP J NOT TO SCALE
125
4"k -t �f r
' 1
-7• ASROLLAND MOORE
744
•�! • .,
16
p r
W
rg
.J g j
plor'" «+��RA,INTREE DRIVE .�
w
� r
y ..
HOME STATE BANK
PRELIMINARY SITE PLAN SCALE - 1 "=40'
�
��
'.^w" s 1 %
AtG�t
f+,PlN T�arc ls+,erv�s
QUESTIONS
1. Is detention or water quality needed on site?
2. Is there a potential for shared parking with the Senior Center?
3. Does any shared access agreements exist for the property?
4. Could the building be reduced to 3,000 sf and have more than the
standard number of parking spaces?
S�
Hum
w/ i I spacea
S -&W&VS,0"
4. This development proposal is subject to all applicable standards of the Fort
Collins Land Use Code (LUC), including Article 3 General Development
Standards, and Division 4.19 Neighborhood Commercial District
5. When developing your plans, pay particular attention to the following
sections of the Code:
• 3.5.1(B) and (E) Architectural Character and Building Materials
• 3.5.1(E)(2) and (3) Glare and Windows
• 3.5.3 Mixed -use Institutional and Commercial Buildings
• 3.8.7 Signs
6. This property will be subject to the design and land use standards within the
NC (Neighborhood Commercial) zoning district, including but not limited to:
minimum building frontage and building height.
7. You will need to set up an appointment to submit your application with
Ginger Dodge in Current Planning at 221-6750. Incomplete submittals will
not be accepted.
8. Please let me know if you have any questions about the requirements for
your submittal.
61,
Stormwater
Contact Info: Glen Schlueter, 221-6700, gschlueter@fcgov.com
1. This site is in the Spring Creek drainage basin where the new development
fee is $2175.00/acre which is subject to the runoff coefficient reduction. This
fee is to be paid at the time a building permit is issued.
2. A drainage and erosion control report and construction plans are required
and they must be prepared by a Professional Engineer registered in
Colorado.
3. Onsite detention is required with a 2 year historic release rate for water
quantity and extended detention is required for water quality treatment.
These are required if there is an increase in imperviousness greater than
1000 square feet. If there is less than 1000 but more than 350 square feet
of new imperviousness a site grading plan is all that is required. Parking lot
detention is allowed as long as the maximum depth is one foot or less.
4. The outfall for this site would probably be the curb and gutter of either
Raintree or Shields. There is an outfall system on the Senior Center site but
the system would need to be analyzed to see if it could take the additional
runoff. This storm sewer system does extend to inlets in Evenstar Court and
Raintree Drive.
Natural Resources
Contact Info: Doug Moore, 224-6143, dmoore@fcgov.com
1. Please contact Tim Buchanan at 221-6361, thuchanan@fcgov.com
regarding the existing trees on the site. Depending on their size, health and
desirability of the species, they may be determined to be significant.
Transportation Planning
Contact Info: Dave Averill 416-2643, daverill@fcgov.com
1. When you start to develop your plans in more detail, please provide a
connecting walkway. One obvious location would be off Raintree adjacent
to the head in parking. If the walkway goes along head in parking, it needs
to be 6 feet wide.
2. 1 will research the history of why the sidewalk north of Raintree is attached.
It should really be detached to standards (6 foot walkway with 10' parkway).
3. Please provide bike racks in a location convenient to bikers near the door.
Current Planning
Contact Info: Anne Aspen 221-6206, aaspen@fcgov.com
1. The schematic design presented at conceptual review shows you've thought
out some of the main issues I see with the site already. Please maintain
your build -to lines as you develop the plan further. And to echo David's
comments, I will want to see pedestrian connections and amenities once
you've developed the site more thoroughly.
2. 1 encourage you to take advantage of the opportunity to create a space with
other uses in addition to the bank. There is good demand for small
business/office/small retail space so you could tap into more value both now
and in the future with a larger footprint, perhaps even going up. You might
be able to collaborate with businesses needing parking at different times to
solve your parking issue.
3. The entire Fort Collins Land Use Code (LUC) is available for your review on
the web at httg://www.colocode.com/ftcollinsAanduse/begin.htm
U
contact at the Senior Center but if not, contact us and we'll put you in touch
with appropriate staff. Assuming the parties agree, an access easement
agreement would be drawn up by Ralph Campano, the City's Real Estate
Manager (221-6275 or rcampano@fcgov.com), then would be taken before
City Council for approval. Council would need to approve of the cross -
access easement prior to final approval of the plans.
4. As you correctly assumed, no access will be permitted from Shields. Access
off Raintree is permitted, assuming you can make it on the west side of your
site. The access point needs to be 175' from the centerline of Shields and
30' from the edge of the Senior Center parking lot entrance. Left turns could
be tricky off Raintree. It might need to be a right in right out access because
of the length of the left turn lane on Raintree. Please contact Eric Bracke in
Traffic Operations regarding this topic to determine possible solutions.
5. Right-of-way dedications for streets and utility easements will need to be
made for this project. Shields is a 4 lane arterial and the ROW is 115' total
(57.5' to the centerline of Shields). Add an additional 12' if a right turn lane
is needed for southbound Shields. Raintree's ROW is 72' plus any
additional needed for turn lanes. The standard utility easement width for
Shields is 15' and 9' is standard for Raintree.
6. A repay may be due for the work recently done on Shields. Contact Matt
Baker to find out at (970) 221-6605.
7. Any existing damaged sidewalk and curb and gutter will need to be repaired
or replaced.
8. Utility plans, a development agreement and a development construction
permit will need to be prepared for this project.
9. Any public improvements must be made according to Larimer County Urban
Area Street Standards.
10. Owner will be responsible for undergrounding any remaining overhead
utilities.
Light and Power
Rob Irish, 224-6167, rirish@fcgov.com
1. The existing service is located on Shields and on the south side of Raintree.
2. The transformer location will need to be coordinated between the applicant
and the City. It needs to be within 10' of pavement. If it is located such that
the shared access is the most logical way for a repair truck to reach it, then
a utility easement will be needed in addition to the shared access easement.
3. Electric capacity and building site charges apply to this project.
4. Any system modifications or relocation will need to be done at the owner's
expense.
Water / Wastewater
Contact Info: Roger Buffington, 221-6854, rbuffington@fcgov.com
1. There is an existing 8" sanitary sewer on Shields. There is a 30" water main
on Shields and an 8" water main on Raintree.
2. Currently this site uses a septic system. This system needs to be
abandoned and you need to connect to the sewer system on Shields.
3. Water service exists on the site to the Shields main. It runs diagonally to the
intersection.
4. Water conservation standards apply to this project.
3
CONCEPTUAL REVIEW STAFF COMMENTS
City of Fort Collins
ITEM: Home State branch bank and possible office/retail space,
NW corner of Raintree and Shields
MEETING DATE: August 16, 2004
APPLICANT: Scott Sinn, ASLA
BHA Design Inc.
4813 Innovation Dr.
Fort Collins, CO 80525
LAND USE DATA: Request to build a branch bank and office/retail space. Existing
buildings will be demolished. The property is within the City of Fort Collins and is
currently zoned NC - Neighborhood Commercial. The following departmental agencies
have offered comments for this proposal.
COMMENTS:
Zoning .
Contact Info: Jenny Nuckols, 416-2313, jnuckols@fcgov.com
1. A branch bank and office/retail space are permitted uses in the NC district
and would be subject to a Type 1 (Administrative) review.
2. Please refer to LUC Section 3.2.2 to ensure that the parking you provide is
in compliance with the code. There is a maximum parking allowance of 3.5
spaces per 1000sf. You will need to provide two handicap parking spaces,
one of which needs to be van accessible.
3. The building must be at least 20 feet but at or fewer than 5 stories in height.
Engineering
Katie Moore, 221-6605, kamoore@fcgov.com
1. Street Oversizing Fee for Fort Collins will apply. Fees vary by use. As of
2001, a bank with drive -up would carry a maximum fee of $11.03/sf, general
office $4.06/sf, commercial $6.24/sf, specialty retail $4.03/sf. The applicant
may contact Matt Baker at (970) 224-6605 for an updated estimate of the
fees.
2. A Traffic Impact Study will need to be submitted for this project. The
applicant will need to contact Eric Bracke at (970) 224-6062 for a scoping
meeting.
3. If you want to pursue shared access and/or parking with the Senior Center
and/or the veterinarian clinic, please contact them directly about the
feasibility and to check their interest level. It sounds like you already have a
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 22 N. College Ave. PO. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750
CURRENT PLANNING DEPARTMENT
Comma_ ry Planning and Environmenta, _ ervices
Current Planning
City of Fort Collins
August 13, 2004
Scott Sinn, ASLA
BHA Design, Inc.
4.813 Innovation Dr.
Fort Collins, CO 80525
Dear Mr. Sinn:
For your information, attached is a copy of the Staff's comments for your proposal for a
&me State Branch Bank at the NW corner of Raintree and Shields which was
presented before the Conceptual Review Team on August 16`h, 2004.
The comments are offered by staff to assist you in preparing the detailed components
of the project application. Modifications and additions to these comments may be made
at the time of formal review of this project.
If you have any questions regarding these comments or the next steps in the review
process, please feel free to call me at 970-221-6750.
Sincerely,
Anne H. Aspen
City Planner
Cc: project file
Project Planner
Cc via email:
Jenny Nuckols
Katie Moore
David Averill
Rob Irish
Glen Schlueter
Roger Buffington
Doug Moore
Karen McWilliams
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020