Loading...
HomeMy WebLinkAboutHAAS SUBDIVISION - FDP - 1-05A - CORRESPONDENCE -Be sure and return all of your redlined plans when you submit your mylars to the Current Planning front desk. You should submit 3 copies of the plat on mylar. The owner's block certification and notary should be completed on each in. black ink before submitting to the city. Once the mylars are submitted and the development agreement is complete and signed, the City will obtain the remaining required signatures and record the plat with the City and the County. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Shelby Sommer Planning Technician Page 4 [5/10/051 [3/22/051 [2/14/05] WATER SUPPLY: Residential (Within GMA) No Residential building can be greater then 400 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 800 feet along an approved roadway. Each hydrant must be capable of delivering 1000 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Number: 27 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] SPRINKLER REQUIREMENTS: These proposed buildings may be required to be fire sprinklered. NOTE: When any portion of the facility or any portion of an exterior wall of the first story of the building is located more then 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility it shall be fire sprinklered. 1997 UFC 902.2.1 Number: 28 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] STREET NAMES: Street names shall be verified and reviewed by County / City Planning Dept. prior to being put in service. 1997 UFC 901.4.5 Number: 29 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] CUL-DE-SAC: A dead-end street cannot exceed six -hundred -sixty (660) feet in length. The turn- around at the end of the street must have an outside turning radius of fifty (50) feet or more, and an inside turning radius of twenty-five (25) feet. Short fire lanes are permitted to facilitate a second point of access when a street is greater then 660 feet. All structures beyond the 660 feet limit must be fire sprinklered if a second point of access cannot be provided. FCLUC 3.6.2 (B) (C); 3.6.6 (1); 1997 UFC 902.2.2.3 Number: 30 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] ***When building site plans are submitted additional and more specific fire department requirements may be required.*** Department: Transportation Planning Issue Contact: David Averill Topic: General Number: 34 Created: 5/17/2005 [5/17/05] No Comments. Page 3 [5/11/051 No remaining issues. Department: PFA Issue Contact: Michael Chavez Topic: General Number: 23 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] REQUIRED ACCESS: A fire department access road shall be provided and maintained unobstructed. 1997 UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1 The criteria for a required fire lane contain several conditions that must be met. 1. The minimum width shall be 20 feet. 2. Inside turning radius shall be 25 feet and outside turning radius shall be 50 feet. 3. Compacted road base shall be used during the construction phase only. The permanent fire lane shall consist of asphalt or concrete and shall be required to support 40 tons 4. The fire lane shall be platted as an "Emergency Access Easement" on the final plat. Number: 24 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] PREMISES IDENTIFICATION: Approved numerals or addresses shall be provided for all new and existing building in such a position as to be plainly visible and legible from the street or road fronting the property. 1997 UFC 901.4.4 A. In Multi -story buildings the following requirements shall pertain. 1. The first floor units shall be designated with 100's. 2. The second floor units with 200's 3. The third floor units with 300's, and so forth. B. All brass letters and numerals shall be posted on a black background. C. Some multi -family layouts may require address postings from the back side as well as the front of the buildings. D. A clockwise addressing pattern shall be maintained when ever possible. E. An addressing scheme shall be submitted to the fire department for approval prior to being posted on the building. Number: 25 Created: 2/14/2005 [5/10/05] [3/22/05] [2/14/05] WATER SUPPLY: Commercial No commercial building can be greater then 300 feet from a fire hydrant. Fire hydrants are required with a maximum spacing of 600 feet along an approved roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute at a residual pressure of 20 psi. 1997 UFC 901.2.2.2 Number: 26 Created: 2/14/2005 Page 2 City of Fort Collins TIERRA SURVEYS, INC RICK TOTH, PLS PO BOX 138 DRAKE, CO 80515 STAFF PROJECT REVIEW Date: 05/18/2005 Staff has reviewed your submittal for HAAS SUBDIVISION PDP, FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Katie Moore Topic: General Number: 35 Created: 5/20/2005 [5/20/05] Please add the following note to the plat: No buiding permit shall be issued on any lot until utility, drainage, and public improvement plans have been submitted to and approved by the city. Number: 5 Created: 1 /21 /2005 (5/10/05] [3/16/051 FYI - the DA will be drafted during Final Compliance, after the hearing. [1/21/05] A Development Agreement will be required with this replat. The DA will address such issues as: repays due for work already completed on Taft Hill, improvements triggered by development of these lots, and access issues onto Taft Hill, among other topics. Number: 7 Created: 1 /21 /2005 [5/10/05] 1 apologize if there was confusion about what to do with the offsite access easement. It should not have been recorded at the county yet, since it was not formally accepted by the City yet. The City has now officially accepted it (appropriate signatures have been obtained), and it will now have to be re -recorded with the County. Please submit a check to Engineering for $21 for recording fees to do so (made out to the Larimer County Clerk and Recorder). [3/16/05] Since this offsite easement will be a public easement, please complete the standard deed of dedication, and include a legal description and sketch of the easement location. (as previously discussed) [1/21/05] The granting of the access easement cannot be done via this plat since the easement is not within the confines of this plat. Please determine to whom it should be dedicated, complete the easement via separate document, and provide a copy for City files. Department: Natural Resources Issue Contact: Doug Moore Topic: General Number: 33 Created: 5/11/2005 Page 1