HomeMy WebLinkAboutCOLUMBINE EAST LONG TERM CARE - PDP - 11-05 - CORRESPONDENCE - REVISIONSNumber: 25 Created: 3/24/2005 [3/24/05] Show/label a sidewalk ramp for the handicap parking spaces. Labels have been added to the sidewalk ramps for the handicap parking spaces. Reference site plan. Sincerely: Sandy McFeron Project Manager V.F. Ripley Associates, Inc. Fraser Walsh Project Manager TST, Inc. Consulting Engineers Number: 32 Created: 3/29/2005 [3/29/05] Provide concrete encasement on all storm sewers which cross above or within 18-inches vertically of a water line. CONC. ENCASEMENT OF JOINTS WAS ADDED AND SHOWN ON STORM SEWER P AND P SHEETS. A DETAIL FOR JOINT ENCASEMENT IS ALSO ON SHEET 14 Number: 33 Created: 3/29/2005 [3/29/05] Add a gate valve on the downstream side of the proposed fire hydrant tee. Provide a utility easement for the proposed fire hydrant. Is an 8-inch fire line needed for this development? GATE VALVE WAS ADDED TO THE UTILITY SHEET Number: 34 Created: 3/29/2005 [3/29/05] Provide flow calculations which will justify the need for a 8-inch sanitary sewer service. A LETTER WILL BE SUBMITTED FROM AE ASSOCIATES SHOWING DESIGN CALCS Number: 35 Created: 3/29/2005 [3/29/05] See site, landscape and utility plans for other comments. So noted. Department: Zoning Issue Contact: Peter Barnes Topic: Zoning Number: 23 Created: 3/24/2005 [3/24/05] Please indicate the lot square footage on plat sheet 2 of 2. Also label the lot on plat sheet 2 of 2 as "Lot 1, or Tract A" or something similar. The lot has been labeled Lot 1 Block 1 with acres and square footage. Number: 24 Created: 3/24/2005 [3/24/05] The parking stalls along the north lot line are only allowed to be reduced to a 17' depth if they overhang a 6' wide walk or landscape strip (Sec. 3.2.2(L)(4) of the LUC). The plan indicates that the width of the landscape strip is only 5% therefore the parking stalls need to be 19' in depth. A variance request is being submitted with revisions. Topic: Retaining Wall Number: 38 Created: 3/29/2005 [3/29/05] At final, please provide a detail of the retaining wall being proposed in the detention pond. A retaining wall detail has been added to Detail sheet 14. TOP and TOE elevations are called out on grading plan in each of the retaining wall viewports. Topic: Utility Plans Number: 39 Created: 3/29/2005 [3/29/05] Please call out size and type of proposed storm sewers on the overall utility plan. Storm sewer sizes and type have been labeled in Utility plan. Department: Transportation Planning Issue Contact: Kurt Ravenschlag Topic: Transportation Number: 40 Created: 3/29/2005 [3/29/05] A direct pedestrian walkway to Lemay Ave. along the north side of the building is highly recommended. The sidewalk on the north side of the building has been modified to extend to Lemay Avenue for a direct pedestrian connection. Reference site plan. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 29 Created: 3/29/2005 [3/29/05] Include the standard general note pertaining to all water mains shall be D.I.P. encased in polywrap. NOTE WAS INCLUDED ON THE UTILITY PLAN AND ALL PIPES WERE CALLED OUT AS D.I.P. Number: 30 Created: 3/29/2005 [3/29/05] The connection for a 3-inch water service is to be a 4-inch tap with a 4-inch gate vale and a 4-inch by 3-inch reducer. THIS WAS CHANGED ON THE UTILITY PLAN SHEET 7 Number: 31 Created: 3/29/2005 [3/29/05] Place all misc. storm sewer details on the storm sewer plan and profile sheets. AN EXTRA PAGE WAS CREATED FOR THE UNDERDRAIN/MISC STORM Department: Natural Resources Topic: General Number: 36 [3/29/05] No issues. So noted. Issue Contact: Doug Moore Created: 3/29/2005 Department: Police Issue Contact: Joseph Gerdom Topic: General Number: 41 Created: 3/30/2005 [3/30/05] Parking lot and drives require min of 1.Ofc Location of BB fixture at south is blocked by BH Spruce - move fixture away from plant massing. Similar issue with south BB on west side - relocate north. Light fixtures at west entrances should provide 1.Ofc. Recommend fixture on west side where facility sidewalk meets sidewalk along Lemay. Recommend lighting along internal walkways on north, south, and west. Landscaping has been adjusted to maintain separation distances. Department: Stormwater Utility Issue Contact: Basil Harridan Topic: Off -site easements Number: 37 Created: 3/29/2005 [3/29/05] The construction of ST-1 will involve acquiring an off -site easement from the owners of Tract A of Oakridge, if the area within Tract A where the work is proposed is already a drainage easement, then approval from the owner of that property should be secured. A drainage easement has been worked out with Everitt Companies to allow for the construction of the off -site storm sewer. A reception # is not available at this time, but the easement has been shown on our Plat and throughout the plan set. Topic: Plat Number: 26 Created: 3/28/2005 [3/28/05] Please add a drainage easement for all areas encompassed within the proposed detention ponds. Private Drainage Easements have been added to Plat and are shown in the plan set. Number: 17 Created: 3/18/2005 [3/18/05] Please provide vertical detail(s) of retaining walls. A retaining wall detail has been added to Detail sheet 14. TOP and TOE elevations are called out on grading plan in each of the retaining wall viewports. Topic: Plat Number: 9 Created: 3/18/2005 [3/18/05] Please use most current plat language (see attached). The language shown is several years old. The plat language has been updated. Number: 10 Created: 3/18/2005 [3/18/05] The emergency access easement should be dedicated only in the drive aisle and no parking areas/landscaping/curb/etc. should be within that easement. The emergency access easement has been moved to fall within the drive aisle. Number: 11 Created: 3/18/2005 [3/18/05] Please show all easements on the plat. A drainage easement has been added to the other easements on the plat. Topic: Utility Plans Number: 20 Created: 3/18/2005 [3/18/05] Show approximate street cuts and add note: Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards. Approximate street cuts and notes have been added to Utility plan. Department: Light & Power Topic: General Number: 1 [3/10/05] No Comments. So noted. Issue Contact: Doug Martine Created: 3/10/2005 Number: 22 Created: 3/18/2005 [3/18/05] The variance request for driveway separations on Lemay needs to be rewritten - it needs to address Oak Ridge to the north, and the church driveway to the northwest, which is very close to this proposed drive cut. Safety, health, and welfare of the public needs to be addressed as well, and the request needs to be stamped. It might be helpful to review LCUASS 1.9.4 for the items needed in a variance request. It is the City's intent to grant the variance once the revised request is received. So noted. Reference revised variance request. Number: 27 Created: 3/29/2005 [3/29/05] It appears that a segment of the proposed stormwater line offsite (northeast corner) is not within an existing easement. Please provide a letter of intent from that property owner prior to scheduling a hearing, and the completed deed must be submitted prior to mylars. A drainage easement has been worked out with Everitt Companies to allow for the construction of the off -site storm sewer. A reception # is not available at this time, but the easement has been shown on our Plat and throughout the plan set. Number: 28 Created: 3/29/2005 [3/29/05] Please see redlines for any additional comments. So noted. Topic: Grading Number: 13 Created: 3/18/2005 [3/18/05] The grades in the ROW and across the sidewalk appear to be too steep to meet ADA for the sidewalk (2% cross -slope) and the slope requirements for 2' each side of walk (2%). The maximum slope in the ROW is 4:1. Anything above that would require a retaining wall, which would require an engineering variance, which would not be looked upon favorably. 2' each side of walk has been re -graded to 2%. Sidewalk and ROW grades have been checked. Number: 16 Created: 3/18/2005 [3/18/05] Offsite grade lines should be shown for at least 50' offsite. Offsite contours have been added to the 50' requirement. Number: 5 Created: 3/18/2005 [3/18/05] The proposed 10' utility easement on Lemay still needs to be approved by XCEL. A letter from XCEL will be submitted acknowledging their approval. Number: 6 Created: 3/18/2005 [3/18/05] The portion of the sidewalk on Rule that is located outside of the ROW needs to be placed in a public access easement on the plat. A public access easement has been added to the Plat. Number: 7 Created: 3/18/2005 [3/18/05] Parking setbacks (LCUASS Ch. 19) need to be met from both Rule and Lemay. On Lemay, the first parking stall should be no closer than 75 feet from the Lemay flowline. On Rule, the first parking stall should be no closer than 50' from the Rule flowline. Parking adjacent to Lemay Avenue and Rule Drive has been revised per LCUASS Ch. 19 standards. Reference site plan. Number: 8 Created: 3/18/2005 [3/18/05] On the site plan, please label existing ROW widths for Lemay and Rule, and proposed parkway widths. ROW and parkway widths have been added. Reference site plan. Number: 18 Created: 3/18/2005 [3/18/05] The standard radius for the driveway onto Lemay is 20% not 25'. A variance request is being submitted with revisions. Number: 19 Created: 3/18/2005 [3/18/05] Driveways should be concrete to ROW line. If the concrete is extended beyond that, an expansion joint should be provided at the ROW line. Concrete has been moved to ROW line. Number: 21 Created: 3/18/2005 [3/18/05] Please see redlines and utility plan checklist for any additional comments. So noted. Number: 14 Created: 3/18/2005 [3/18/05] Please use the standard under -walk drain from the pond onto Rule - straight chase (no bends) and only 2' wide unless otherwise approved by Stormwater. Also, the metal covering should extend from 2' behind the walk out to the curb, per the detail. Sidewalk culverts were changed to D10's and called out as such in the Grading and Concrete plans. A D10 detail was added to Detail sheet 14. Number: 15 Created: 3/18/2005 [3/18/05] The offsite work shown northeast of the project - are there existing easements to accommodate this? Please show/label/include the reception number of these easements, or provide a letter of intent from the adjacent property owners to dedicate needed easements. A drainage easement has been worked out with Everitt Companies to allow for the construction of the off -site storm sewer. A reception # is not available at this time, but the easement has been shown on our Plat and throughout the plan set. Topic: General Number: 2 Created: 3/18/2005 [3/18/05] The sidewalk along Lemay should be located at the back of the ROW, as opposed to meandering in the middle of the parkway. Also, the new street trees should be located in the ultimate parkway, approximately 5' from the edge of the walk when it is placed against the ROW. A variance request is being submitted with revisions. Number: 3 Created: 3/18/2005 [3/18/05] All plans need to meet the scannability requirements in LCUASS appendix E. Questions about scanability can be directed to JR or Tim in Technical Services. So noted. Number: 4 Created: 3/18/2005 [3/18/05] The driveway onto Rule Drive should be a standard cut, not radius style. A variance request is being submitted with revisions. v F�IPIEiy.SSOGIATES INC Landscape Architecture Urban Design Planning April 27, 2005 Mr. Ted Shepard Fort Collins Planning Department 281 North College Avenue Fort Collins, CO 80524 Columbine East Long Term Care — TYPE II Response to staff Project Review comments Dear Mr. Shepard, We have reviewed the staff letter dated April 05, 2005 and have the following comments: Please note the site plan and building plan have been completely redesigned since conceptual review. ITEM: 131-Bed Nursing Home at 4824 South Lemay Avenue (Rule Property — northeast corner of Lemay Avenue and Rule Drive) COMMENTS: Department: Engineering Issue Contact: Katie Moore Topic: Drainage Number: 12 Created: 3/18/2005 [3/18/05] Approximately 25% of the site is shown to drain to the driveway to Rule and over the public sidewalk onto the street. This is not allowed. The water must be diverted, perhaps to an under -walk drain, so that it does not cross the walk. Does this water need to be treated? A 10' grated inlet, trickle pan and Di sidewalk culvert were added to the southeast corner of the site to direct runoff to Rule Drive and not cross over the sidewalk. The undetained area was included in calculations for the Water Quality Control Volume in Detention Pond 3. This way, we are treating a greater volume in Pond 3 to account for the undetained/untreated runoff that is being released directly to Rule Drive. Phone 970.224.5828 Fax 970.224.1662 401 West Mountain Ave. Suite 201 Fort Collins, CO 80521-2604 Oripley.com