Loading...
HomeMy WebLinkAboutSUNRISE RIDGE, 2ND FILING - PDP - 13-05D - CORRESPONDENCE - (5)[1/9/07] The text in the drainage report is not site specific and looks to be the same as filing 1. Please include text regarding the sub -basin flow routing for this site and any variances for this specific PDP. This report can reference the Sunrise Ridge Filing 1 report regarding the SWMM design and other design information pertaining to both filings. Number: 29 Created: 2/26/2007 [2/26/07] Stormwater is ready for a hearing. Additional comments may follow at final compliance. Comment from Current Planning: 1. As discussed at the project review meeting, there may be flexibility with regard to not placing a streetlight at the end of the cul-de-sac due to proximity to roadway lighting on Rock Creek Drive. This idea should be taken up with Light and Power. Be sure and return all of your redlined plans when you re -submit. As always, if you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Ted Shepard Chief Planner Page 3 Topic: Plat Number: 19 Created: 1 /12/2007 [2/28/07] A note was provided but only addressed Strauss Cabin Road, why not Rock Creek Drive as well? [1/12/07] Please provide a note on the plat that no lots shall be allowed vehicular (driveway) access directly onto Strauss Cabin Road or Rock Creek Drive. Number: 31 Created: 3/1 /2007 [3/1/07] Technical Services has the following comments: 1. Boundary and legal close. 2. Typo in legal. Bearing from P.O.C. to T.P.O.B. is incorrect. 3. Please show the same note about Strauss Cabin Road as on the first plat. 4. Who owns and maintains Tract A. 5. Plat needs note vacating easements on old Tract B&C. (Comments 3-5 are carryover from the previous round.) Topic: Utility Plan Number: 14 Created: 1/12/2007 [2/28/07] Carried over as unaddressed. [1/12/07] Please use the same type of detail for the cul-de-sac construction of hand forming the curb and gutter as was done on two other Northern Engineering projects, Lemay Avenue Estates and McClelland's Creek. Number: 24 Created: 1 /12/2007 [2/28/07] This does not appear to have been addressed but can be worked on at time of final plan submittal. [1/12/07] In general please provide a different lineweight/linetype to discern improvements to be done with the 1st Filing. (Rock Creek Drive, spot elevations on Rock Creek Drive, etc.) Isn't the sidewalk on the south side of Rock Creek Drive proposed to be built with the 1st Filing? Department: Light & Power Issue Contact: Doug Martine Topic: Landscape Plan Number: 26 Created: 2/16/2007 [2/16/07] A landscape plan showing the planned electric vaults and streetlights was sent to the landscape architect on Feb. 16, 2007. Trees must be a minimum of 5 ft. from electric vaults and 40 ft. from streetlights (15 ft. if the tree is an ornamental). It appears that this will require the tree on Rock Creek Dr., just west of Sunglow Ct. to be relocated. Also, the tree shown between lots 2 & 3 will need to be eliminated. Topic: Utility Plan Number: 25 Created: 2/16/2007 [2/16/07] The water service to lot #5 will need to be moved to the east to provide a location for an electric vault & service. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 5 Created: 1 /9/2007 [2/28/07] At final compliance, we can discuss how to address this comment. Page 2 i STAFF PROJECT REVIEW City of Fort Collins KELLY SMITH Date: 03/07/2007 5101 STRAUSS CABIN ROAD FORT COLLINS, CO 80528 Staff has reviewed your submittal for SUNRISE RIDGE, 2ND FILING PDP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Dana Leavitt Topic: General Number: 9 Created: 1 /11 /2007 [2/26/07] Please indicate on the plans the assessment and evaluation of Tim Buchanan, City Forester. Topic: Landscape Plan Number: 27 Created: 2/26/2007 [2/26/07] In the response letter from One Earth Solutions states that an existing row of evergreen trees in located on the adjoining property to the south. Please show on the plans. Number: 28 Created: 2/26/2007 [2/26/07] The site and landscape plan do not differentiate between existing trees and proposed trees. If all of the trees within the Rock Creek Drive ROW are existing, show as existing. Department: Engineering Issue Contact: Marc Virata Topic: General Number: 13 Created: 1 /12/2007 [2/28/07] Please provide for a type III barricade at the termination of the sidewalk along the southern boundary of the property. [1/12/07] Sidewalk on Strauss Cabin Road needs to be designed and built with the project. Please ensure that it is reflected on all plan sets, including with grading information. Number: 20 Created: 1 /12/2007 [2/28/07] Carried over for reference. [1/12/07] As a heads -up, there will need to be development agreement language stipulating that with certain lots in the development having double frontage onto public streets, they are required per code to have maintenance responsibilities for both Strauss Cabin Road and Sunglow Court (and with lot 7 also responsible for Rock Creek Drive). Number: 22 Created: 1 /12/2007 [2/28/07] Carried over for reference. [1/12/07] The local street portion of Strauss Cabin Road abutting the site will need to be provided. Page 1