Loading...
HomeMy WebLinkAboutKINGDOM HALL - FDP - 18-05C - CORRESPONDENCE - (3)Department: Stormwater-Water-Wastewaterlssue Contact: Wes Lamarque Topic: Drainage Number: 82 Created: 6/14/2006 [6/14/06] In the text of the report, please add that lot 2 is responsible to connect an outfall to the property line once an offsite outfall is created. Number: 83 Created: 6/14/2006 [6/14/06] The City will maintain storm sewer 2A and only part of storm sewer 2, from inlet 2-1 to the flared -end section. Please remove note on plans stating the City will maintain all of storm sewer 2. Number: 84 Created: 6/14/2006 [6/14/06] The grading around detention pond 1 has some errors. See redlined plans. Number: 85 Created: 6/15/2006 [6/15/06] Please revise water quality outlet structure per redlines. Topic: Erosion/Sediment Control Number: 81 Created: 6/14/2006 [6/14/06] What is the re -vegetation plan for the ponds? Please put a note on the plan indicating whether they are to be landscaped or just re-vegetated/mulched. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Ted Shepard Chief Planner Page 3 Topic: Technical Services -Survey Number: 86 Created: 6/15/2006 [6/15/06] Please remove hatch lines over text Number: 87 Created: 6/15/2006 [6/15/06] Show the limits and area for each road dedication Topic: Timberline Rd Number: 78 Created: 5/31 /2006 [5/31/06] Refer to Timberline Ultimate Design: the taper length on the left turn lane northbound does not meet standard design requirements. For a 50 mph design speed, the taper should be 200 feet. Number: 79 Created: 6/6/2006 [6/6/06] Add a variance note to sheet 2 for the shallow cover over storm sewer pipe, Storm 1, shown on sheet 7. Department: Engineering Issue Contact: Sheri Wamhoff Topic: Utility plans Number: 48 Created: 12/2/2005 [5/31/06] [4/18/06] [12/2/05] Please make sure all documents meet scanning requirements. See appendix E-6 for requirements. Number: 66 Created: 4/18/2006 [5/31/06] New proposed drainage easement for the detention pond to the north is not being shown on the plat. [4/18/06] The utility plans need to show all the easements being dedicated with the plat — missing a few. Department: Engineering Issue Contact: Randy Maizland Topic: Utility plans Number: 75 Created: 5/31 /2006 (5/31/06] The property owners name, address and phone number shall be placed on the cover sheet. A reference to the latest updated soils report shall be placed on the cover sheet or on the grading plan sheet. Number: 76 Created: 5/31/2006 [5/31/06] Please remove the City signature approval block from the Demolition Plan sheet. This plan is for reference only and will not be signed by the City. Page 2 6aSTAFF PROJECT REVIEW City of Fort Collins THE FREDERICKSON GROUP, LLC Date: 06/16/2006 C/O DEANNE FREDERICKSON 7711 WINDSONG DR WINDSOR, CO 80550 Staff has reviewed your submittal for KINGDOM HALL PDP - TYPE II & FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Sheri Wamhoff Topic: General Number: 33 Created: 7/12/2005 [5/31/06] Development Agreement information. [4/18/06] [11/29/05] Keeping this in, so it is transferred to the Development Agreement. [7/12/05] Street Oversizing has indicated that a repay agreement for this property may exist. Please contact Matt Baker for more information. Number: 34 Created: 7/12/2005 [5/31/06] See Plans for additional comments [4/18/06] [11/29/05] See plans for additional comments. [7/12/05] See plans for additional comments. Topic: Kechter RD Number: 56 Created: 4/18/2006 [5/31/06] The vertical curve (sag) K value still does not meet the minimum of K=90 for Kechter. [4/18/06] The vertical curve on Kechter doesn't meet minimum K value. Number: 59 Created: 4/18/2006 [5/31/06] Vertical curve on ultimate design for Kechter still does not meet the minimum K value. [4/18/06] Ultimate Kechter Road. As with the interim the K value does not meet minimum for the vertical curve. Department: Engineering Issue Contact: Randy Maizland Topic: Kechter RD Number: 77 Created: 5/31 /2006 [5/31/06] Please refer to sheet 10, Kechter interim improvements: A left turn "bubble" separation must be striped for traffic safety. This is at the request of the traffic engineer who will be signing the plans. Page 1