HomeMy WebLinkAboutKINGDOM HALL - ODP - 18-05A - CORRESPONDENCE - (3)Please indicate the future right turn lane for westbound Kechter, with an arrow. The annexation and zoning request is being processed as "Kingdom Hall." Please use this as the main title for the O.D.P. to be consistent. Additional comments are on the attached redlined plan. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Ted Shepard Chief Planner Enc. Page 4 Department: Transportation Planning Issue Contact: David Averill Topic: Utility Plan Number: 6 Created: 4/26/2005 [4/26/05] The walkway in the parking median that leads to the front door scales out at 4'. This should be widened to at least 5' to facilitate the passing of oncoming groups of people. Seems like there is plenty of room in the median (scales out at 10 feet) to achieve this. Number: 7 Created: 4/26/2005 [4/26/05] Please add an access ramp to the walkway (running in the parking median) between the handicap parking stalls. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 16 Created: 4/28/2005 [4/28/05] There are no comments pertaining to the ODP, however the following comments are for the PDP level submittal. -Place the proposed sanitary sewer manhole on the future centerline of Kechter Road. -Will the proposed sanitary sewer main be in conflict with the existing 16-inch water main in Timberline? -Need to explore the options of extending sanitary sewer to the north for future development. See utility plans for other comments. Department: Zoning Issue Contact: Peter Barnes Topic: zoning Number: 1 Created: 4/12/2005 [4/12/05] What land use is anticipated for Lot 2? Department : Current Planning Issue Contact: Ted Shepard I have enclosed two examples of recently approved O.D.P.'s. The drawing needs to be simplified graphically as it now reads more like an ALTA survey. It really only needs to be a "bubble" plan. For example, please delete the topo lines for the streets, the topo lines on the parcel and the existing buildings. Please create two distinct phases, or "bubbles" with clear line dividing the two. The map should be shown in a larger more readable scale. All the text should be in larger font and bolder. Please name the surrounding subdivisions. Please designate the proposed land uses on each lot. For Lot Two, please make your best estimate at this time. Since an O.D.P. is not a document that grants a vested right, the applicant has the flexibility to change the designated land use in the future should that become necessary. Page 3 r [4/27/05] What are the possible uses on each area? Not sure that calling each area lots is the correct terminology for an ODP. Usually we see bubbles with acreage and uses associated with that area. Just doesn't quite look like a standard ODP. Number: 15 Created: 4/27/2005 [4/27/05] Comments on the conceptual site plan No access will be allowed out to Timberline. If an emergency access connection is needed that can be worked out, but an access for general traffic use will not be allowed. The sidewalks and frontage improvements are not shown in the correct location. The sidewalk needs to be placed at the property line/ back of new right-of-way with the standard 10 parkway and curbline placed off of that. Department: Light & Power Issue Contact: Monica Moore Topic: General Number: 2 Created: 4/18/2005 [4/18/05] Nearest available electric is located on the northwest corner of Willow Springs Way and Timberline Road. Developer will be responsible for normal electric development charges for this development. Contact Light and Power for an estimate of these charges. Number: 3 Created: 4/18/2005 [4/18/05] Developer will need to coordinate location of the electrical transformer. This transformer must be located within 10-feet of a paved surface. In addition, a Commercial Service Form (C-1) must be submitted by your electrician in order to determine transformer size. Show existing and planned electric lines on utility plans. Number: 4 Created: 4/18/2005 [4/18/05] Any street trees to be added must maintain minimum clearances to streetlights. (15-feet for ornamental trees and 40-feet for shade trees.) Contact Light and Power to initiate streetlight design. Number: 5 Created: 4/18/2005 [4/18/05] Any relocation of electric facilities will be at developer's expense. Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Stormwater Number: 17 Created: 4/29/2005 [4/29/05] Please show the detention pond and outfall on the ODP as a schematic. No other comments for the ODP. Number: 18 Created: 4/29/2005 [4/29/05] At the PDP level, an outfall for this site needs to be provided and drainage easements are required for all downstream property owners until the outfall enters an existing drainage easement. Using the Timberline Right -of -Way may also be an option. Page 2 r STAFF PROJECT REVIEW Citvof Fort Collins THE FREDRICKSON GROUP Date: 05/05/2005 JEANIE FREDRICKSON 7711 WINDSONG DR. WINDSOR, CO 80550 Staff has reviewed your submittal for KINGDOM HALL ODP, and we offer the following comments: ISSUES: Department: Engineering Topic: General Number: 8 [4/27/05] comments from Technical Services: This drawing does not function well. 1. Can't read all the text. 2. the fade back lines won't reproduce. 3. vicinity map 4. needs work - no text over line work. Issue Contact: Sheri Wamhoff Created: 4/27/2005 Number: 9 Created: 4/27/2005 [4/27/05] Per a discussion and review of the plans with Eric Bracke no access will be allowed onto Timberline Road. Number: 10 Created: 4/27/2005 [4/27/05] Improvements to the Kechter Road Timberline intersection will be needed. At a minimum a left lane and a thru/ right lane will be needed on Kechter Road and a North bound right turn lane is needed on Timberline Road. Number: 11 Created: 4/27/2005 [4/27/05] 1 suggest showing the possibility of cross access to the parcel to the north of Lot 2 on the ODP. At such time as the lot(s) to the north develop an access out to Timberline maybe able to be achieved. Number: 12 Created: 4/27/2005 [4/27/05] 1 don't understand the limits of development line on the ODP. I thought an ODP had to be done for the entire site and then a PDP could come in for only a portion of the site. Number: 13 Created: 4/27/2005 [4/27/05] The ODP does not meet scanability criteria. See Appendix E-6. Number: 14 Created: 4/27/2005 Page l