HomeMy WebLinkAbout210-212 W. MAGNOLIA ST., URBAN LIVING LOFTS - PDP - 24-05 - SUBMITTAL DOCUMENTS - ROUND 1 - TRAFFIC STUDYUrban Living Lofts At Magnolia Street Using the peak hour traffic shown in Figure 2, the peak hour operation is shown in Figure 3. Analysis sheets are included in Appendix D. Figure 3 — Existing Level of Service (am /pm) The key intersections operate acceptably overall during both the morning and afternoon peak hours. Existing Pedestrian Facilities There is a continuous network of pedestrian facilities in the downtown area. The vast majority of the sidewalks are detached walks. Along the frontage of the proposed development, there is an existing four - foot detached sidewalk. Existing Bicycle Facilities Bicycle lanes are striped along both Mason and Howes Streets. Along Magnolia, there is a striped bike lane west of Canyon Avenue, and bikes share the traveled way with vehicles between College Avenue and Canyon Avenue. Existing Transit Facilities Transfort, the City's transit service provides service along Mason (northbound) and Howes (southbound). The daytime route is Route 15 and the evening route is 64. The headways are 20 minutes and the closest bus stop to the proposed development is within one -block. Page 4 of 13 Urban Living Lofts At Magnolia Street 090 Figure 2 — Existing Peak Hour Traffic Turning Movement Volumes (am /pm turning volumes) Existing Tra is Operations In order to determine the function of the intersection in the study area, a level of service analysis was completed. The analysis is based on procedures outlines in the Highway Capacity Manual (HCM 2000) published by the Transportation Research Board (TRB). This type of analysis assigns a letter value based on average delay experienced by vehicles to indicate the level of service (LOS) of the intersection. The letter values assigned range from A to F with A being the best. A summary and definition of each LOS letter designation is provided in Table 1 for both unsignalized and signalized intersections. Tnhle 1 — Level nfRervire Definition for Intersections Unsingnalized Intersection Signalized Intersection LOS Average Delay (sec/veh) A <-10.0 510.0 B >10.0and515.0 >I 0.0 and <-20.0 C >15.0 and 525.0 >20.0 and <_35.0 D >25.0 and 535.0 >35.0 and <_55.0 E >35.0 and <-50.0 >55.0 and 580.0 F >50 >80 Source: Highway capacity manuat, Transportation Research Board, 2000 Page 3 of 13 Urban Living Lofts At Magnolia Street 1000 2. EXISTING CONDITIONS Location and Surrounding Area — Land Use The location of the Magnolia Lofts development is in downtown Fort Collins along Magnolia Street between Mason Street and Howes Street. See Figure I — Vicinity Map. The existing land use includes approximately 5,800 sf of small businesses. The area is relatively flat (from a transportation perspective) and the existing land uses are typical of a downtown area. Neighboring properties include single-family residential dwellings, small businesses, offices, and commercial properties. There are several development projects in the area, primarily mixed - use (residential and business) "loft" projects. Existing Roadway System The primary streets in the vicinity of the proposed development are Mason Street, Howes Street and Magnolia Street which fronts the development. The detailed roadways below generally are typical of a central business district area. They typically include on -street parking, striped bike lanes, and curb and gutter. Magnolia Street is a two-lane asphalt roadway with a 57 ft width that runs east -west along the development frontage. It is classified as a local street. The posted speed limit is 25 mph. There is diagonal parking (unlimited in time) along the block between Mason and Howes. Howes Street is the south -bound portion of a one-way couplet just west of College Avenue. It contains three through lanes, on -street parking and striped bike lanes. It is classified as a 2-lane arterial but has an existing speed limit of 25 mph. The intersection at Howes and Magnolia is signalized. Mason Street is the north -bound portion of the one-way couplet. It also is classified as a 2-lane arterial, and has a speed limit of 25 mph. It has two through lanes for vehicles, with the center lane reserved for the railroad. The intersection at Mason and Magnolia is stop controlled for Magnolia Street traffic. Existing Tra fzc Conditions The analysis of existing conditions provides insight into how the existing street network is configured and how well it performs. This information is useful in establishing baseline conditions. Peak hour turning movement counts at the two key intersections were completed in April 2005 — following the re -opening of Mulberry Street. The AM and PM peak hour counts are shown in Figure 2 and raw traffic data is provided in Appendix B. . Page 2 of 13 Urban Living Lofts At Magnolia Street • • • 1. INTRODUCTION The document represents a transportation impact study for the Urban Living Lofts at Magnolia Street — a small, infill, mixed use (residential and businesss) development in the heart of downtown Fort Collins. See Figure 1 — Vicinity Map. Purpose and Process The purpose of this study is to address the existing and future capacity, geometric and control conditions of the transportation system and then determine the impact (and mitigation measures if necessary) of the traffic produced by the proposed development. This was accomplished by first: • Completing a scoping meeting via telephone with the City of Fort Collins Traffic Engineer and Transportation Planning to identify the study area and required analysis (scoping sheets included in Appendix A), ■ collecting existing traffic data, ■ analyzing the performance of the existing intersections, ■ projecting the existing volumes to the short term horizon year of 2010, and ■ analyzing the performance of the street network with future traffic volumes in place. The second portion of the study included: ■ determining the volumes of traffic to be generated by the development, Figure 1— Vicinity Map ■ adding these volumes to the background traffic identified above, ■ analyzing the intersection for site plus the background traffic, ■ comparing the function of the background analysis with the background + site analysis, ■ completing level of service evaluation of pedestrian, bicycle and transit modes, and ■ completing special studies as requested for parking adequacy and sight distance at the development alley access. The final step in the analysis is to identify impacts and specify required mitigation measures to accommodate the transportation impacts due to the development. Page 1 of 13 0 Urban Living Lofts at Magnolia Street 1XX] List of Tables Description Page 1 Level of Service Definition for Intersections............................................................... 3 2 Trip Generation............................................................................................................ 6 List of Figures Description Page 1 Vicinity Map................................................................................................................. 1 2 Existing Peak Hour Traffic Turning Movement Volumes ........................................... 3 3 Existing Level of Service............................................................................................. 4 4 Site Plan ........................................................................................................................ 5 5 Trip Distribution Percentages....................................................................................... 7 6 Site Generated Trip Assignment.................................................................................. 7 7 2010 Background Volumes.......................................................................................... 8 8 2010 Total Volumes..................................................................................................... 9 9 2010 Background LOS................................................................................................. 9 10 2010 Total LOS............................................................................................................ 10 11 Geometrics..................................................................................................................... 10 in Urban Living Lofts at Magnolia Street 000 TABLE OF CONTENTS Section Description Page IIntroduction...................................................................................................................... Purpose and Process 2 Existing Conditions.......................................................................................................... Locations and Surrounding Area — Land Use Existing Roadway System Existing Traffic Conditions Existing Traffic Operations Existing Pedestrian Facilities Existing Bicycle Facilities Existing Transit Facilities 3 Proposed Development.................................................................................................... Development Type, Size, and Timetable Development Access Development Trip Generation Development Trip Distribution and Assignment 4 Future Traffic Volumes and Capacity Analysis............................................................... Background Traffic Projections Total Traffic Projections Operational Analysis Geometry 5 Multi -Modal Level of Service Analysis........................................................................... Pedestrian Level of Service Analysis Bicycle Level of Service Analysis Transit Level of Service Analysis 6 Speciat Analysis Areas..................................................................................................... Parking Adequacy Alley Access Sight Distance 7 Conclusions and Summary of Findings........................................................................... Appendix A: Base Assumption Form Appendix B: Peak Hour Traffic Count Information Appendix C: Trip Generation Worksheets Appendix D: Intersection Analysis Worksheets - Existing Appendix E: Intersection Analysis Worksheets - Short Term Background Appendix F: Intersection Analysis Worksheets — Short Term Total Appendix G: Pedestrian / Bicycle / Transit Level of Service Analysis 2 5 8 11 11 12 Traffic Impact Study Urban Living Lofts At Magnolia Street Fort Collins, Colorado May 3rd, 2005 Prepared for: Urban Living Concepts LLC 210 West Magnolia Fort Collins, CO 80521 G . W14 N --I- AL I Urban Living Lofts At Magnolia Street 000 The comparison of the traffic analysis for the short-term background and short-term total traffic shows minimal impact due to the proposed development. In addition, the analysis was conservative in nature as no trip reduction for the multi -modal assumptions was taken, and the trip generation from existing business uses of the property was not discounted (due to low volumes). The existing geometry at the intersections will continue to provide acceptable levels of service, both with regional growth and the addition of this project. ■ Acceptable Levels of Service are achieved for pedestrians, bicycle, and transit modes based upon the measures in the multi -modal transportation guidelines. This is a small, infill project located in the heart of downtown Fort Collins; although this area is very pedestrian friendly, there are some off -site detached sidewalk widths that vary including some sections between the project and Dunn Elementary that are not 4.5 ft in width. ■ A parking adequacy analysis indicates that with the proposed 24 on -site parking spaces and the existing diagonal spaces along the development's frontage on Magnolia Street, there will be adequate parking for the project. ■ And finally, a review of entering sight distance at the alley indicates that it is similar in design to many other alleys that access local streets. Sufficient sight distance is obtained prior to the vehicles entering the traveled way. Should enhanced sight distance be necessary, an additional parking space adjacent to the alley access could be removed. Page 13 of 13 Urban Living Lofts At Magnolia Street ••• Parking Adeguacv The proposed development will include 18 units of residential lofts and 3000 sf of business. Per the City of Fort Collins land use code, there is a residential parking requirement of 1.5 spaces per dwelling unit for this type of residential use. For the business use, there is a max of 3 spaces / 1000 sf. Therefore the maximum parking requirement is (1.5* 18) + (3*3) = 36 spaces. The minimum would be 27 spaces. The existing frontage along the development has diagonal parking for unlimited time frames.. There are 12 spaces immediately fronting the property (and more along other frontage along the block). The proposed development will be providing covered parking in the first floor of the building. 24 Spaces are included in the conceptual drawings. Therefore a total of 36 spaces are available for the development. This meets the code standard. Alley Access Sight Distance Based upon the LCUASS, the minimum sight distance at driveways for local streets is 260 feet. The entering sight distance from the existing alley (at the "stop bar") onto Magnolia is limited for exiting vehicles due to the existing diagonal parking (in the range of 75 ft when parking spaces are full). However, the parking is prohibited within 10-20 feet of the access and slowly exiting vehicles obtain the necessary sight distance prior to entering the traveled way. This is a similar condition to other alleys in the area, (including the one directly opposite this alley on Magnolia that provides access to a number of businesses) and meets the standard for alley design as shown in Figure 7-12F of LCUASS. Should enhanced sight distance be necessary, the removal of a single parking space next to the alley entrance would provide additional length. ' 7. CONCLUSIONS AND SUMMARY OF FINDINGS This study identified, documented and addressed the transportation impacts of the proposed Urban Living Lofts At Magnolia Street development in downtown Fort Collins. The following conclusions can be drawn from the study: The Urban Living Lofts At Magnolia Street are feasible from a traffic engineering standpoint. At full buildout, there will be 18 loft dwelling units, approximately 3,000 sf of business / storage space, and 24 off-street parking spaces located in the first floor of the building. The project will generate 154 daily trips, including 14 in the am peak hour and 15 in the pm peak hour. The current operation at the two area intersections (Mason / Magnolia and Howes / Magnolia) is acceptable with existing control and geometry. ■ The background traffic is assumed to increase do to regional growth, and other area developments including the Cortina project. Page 12 of 13 I Urban Living Lofts At Magnolia Street • • • 5. MULTI -MODAL LEVEL OF SERVICE ANALYSIS The proposed development is a minor in -fill development located in the heart of downtown Fort Collins. The surrounding area is fully developed and is in an area where multi -modal amenities for pedestrians, bicycles and transit abound. Pedestrian Level of Service Analysis The study area for pedestrians is by definition destinations that are within 1320 ft of the proposed development. This area is shown on the map in Appendix G. Potential destinations include the Central Business District to the north east, County and other offices to the north, the Lincoln Center / Mulberry Pool complex to the west, and the grocery store to the east. In addition, Dunn Elementary School is included in the analysis as that is the designated neighborhood school for the residents of the Magnolia Street Lofts. The pedestrian LOS worksheet is provided in Appendix G. Because this area is downtown, it is designated as a Pedestrian District. The standard Level of Service is B for street crossings and A for all other factors. This level of service is satisfied for all categories. Direct and continuous sidewalks are available to all the destinations, and most are detached (attached walks are those along College Avenue in the CBD). There are no missing links in the network, there is a high visual interest and security appears good. There are some sidewalks (especially between the proposed project and Dunn Elementary) that while easy and inviting to use, are somewhat aging and are not all a minimum of 4.5 feet in width (City standard for a local street). Bicycle Level of Service Analysis The bicycle Level of Service Analysis is also included in Appendix G. The existing striped bike lanes along both Mason Street and Howes Street provide an excellent LOS. Along Magnolia Street, bicycles share the roadway between College Avenue and Canyon Avenue (standard for City of Fort Collins local residential streets). West of Canyon Avenue, there is once again a striped bike'lane. This meets the level of service standards for bicycles. Transit Level of Service Analysis Current transit service is provided to the area in the daytime via Route 15 and in the evening via Route 64. The bus stops are within one block of the proposed development (along Mason and Howes/Magnolia) and typically run with a 20 minute headway. The analysis included in Appendix G shows an acceptable level of service B with three of the four standards being met. 6. SPECIAL ANALYSIS AREAS During the course of the scoping meeting for this intermediate level Traffic Impact Study, two areas of special analysis were identified and are discussed below. Page 11 of 13 Urban Living Lofts At Magnolia Street Figure 10 — 2010 Total LOS An acceptable level of service for unsignalized intersections is considered to be an overall LOS D for signalized intersections and LOS E on any approach leg or movement. For a non -signalized intersection arterial / collector or local, a LOS E is minimum. Both intersections have an arterial component and operate at an acceptable level both with and without the development in the 2010 time horizon. Geometry Figures 11 shows the existing and assumed short-term geometry that was used in the analysis above. The geometrics are acceptable. Figure 11—Geometrics Page 10 of 13 I Urban Living Lofts At Magnolia Street Figure 8 — 2010 Total Volumes am /pm number of turning vehicles Operational Anal 000 A Level of Service (LOS) analysis was completed at each of the intersections in both the am and pm peak hour. The LOS was calculated both without the project development (background only) and with the development traffic (total), allowing for a comparison between scenarios that will highlight the impact of the proposed development. Figure 9 shows the LOS operational results analysis for the short-term (2010) background volumes. Figure 10 shows the LOS operational results for the short-term total volumes. The worksheets for this analysis, including delays and capacities are provided in Appendix E and F. Figure 9 — 2010 Background LOS Page 9 of 13 Urban Living Lofts At Magnolia Street 1000 4. FUTURE TRAFFIC VOLUMES AND CAPACITY ANALYSIS Background Tra ec Projections Based upon the Larimer County Urban Area Street Standards, the short-term horizon year will be in 2010. Due to the level of trip generation, this TIS is an intermediate TIS, and no long term horizon analysis is required. This requires the background traffic (area traffic volumes) to be forecasted to the year 2010. Based upon the scoping meeting, all existing area traffic will be increased by 2% per year to account for regional growth. In addition, the traffic generated by the currently under construction Cortina development and the 310 South College Mixed Use project also needs to be included as background traffic. Both developments were assumed at full occupancy in 2010. Figure 7 shows the non -site, or background traffic at the key intersections for the short-term horizon year of 2010. Figure 7 — 2010 Background Volumes am /pm number of turning vehicles Total Tra rc Projections Using the background traffic volumes shown in Figure 7, and the site traffic volumes shown in Figure 6, the addition of the two will provide the total expected traffic volumes at the key intersections in 2010. The total traffic volumes are shown in Figure 8. Page 8 of 13 and Elementary school Urban Living Lofts At Magnolia Street 1000 Figure 5 — Trip Distribution Percentages 35% to / from rom the south The assignment of the project generated traffic to the surrounding roadways is based upon the distribution percentage and is shown in Figure 6 for the morning and evening peak hour periods of an average weekday. These assignments are made by applying the trip generation estimates of Table 2 to the trip distribution percentages of Figure 5. The morning and evening peak hour traffic volumes are in vehicles per hour. Figure 6 — Site Generated Trip Assignment am /pm number ofturning vehicles Page 7 of 13 11 Development Access Urban Living Lofts At Magnolia Street ••• The access to the development will be along Magnolia Street to the south. Business patrons will likely utilize the existing diagonal parking along Magnolia, while employees and residents of the lofts will utilize the existing alley to the west of the property to access the on -site parking. The alley is 14 ft in width, is a concrete paved facility and appears to meet the standards for a City of Fort Collins alley. The alley is shared use with the single family dwelling to the west of the development. Development Trip Generation In order to determine how many trips the proposed development will likely generate during the identified peak hours, the proposed trip generation characteristics were identified. This process was conducted using the Institute of Transportation Engineers (ITE) Trip Generation Manual, 7'h Edition. The proposed land use includes 18 loft units (land use code 220) and approximately 3,000 sf of business ! storage space (land use code 710). Although a mode split reduction could be utilized in this downtown location, the anticipated 10% reduction is minimal due to the low volumes, and was therefore not used. Likewise, the existing business usage will also be reflected in the existing traffic volumes — but in order to provide a conservative analysis, this likely generation was not discounted. There was also no reduction for internal trips nor passby trips. Trip generation rates are shown in Table 2. Table 2 - Trip Generation Land Use ITE Units Daily Total Trips Enter / Exit Distribution Code Trips AM ; PM AM PM IN OUT IN OUT Lofts 220 18 121 9 11 2 7 7 4 Office Bldg 710 3 33 5 j 4 4 1 1 3 Total 154 14 j 15 , 6 I 8 8 7 Notes: ■ 10% alternate modes would be reasonable to assume, but due to low numbers (less than 10 in each peak hour enter/exit) this was not applied. ■ The 3, 000 sf ofproposed office / storage will be replacing an existing 5,800 sf of small office space. Again, due to low traffic volume numbers, the trip generation for the existing usage (which is technically included in the existing traffic volumes) was not discounted Development Trip Distribution andAssignmen The next step in the traffic analysis for this development is to distribute and assign the new trips generated by the development onto the street network. This was accomplished by analyzing the existing traffic patterns within the study area, thinking through likely destination and travel paths, speaking with City staff, reviewing other recently completed TISs in the area, utilizing professional engineering judgment and then applying the resultant distribution. The distribution percentages are shown in Figure 5. Page 6 of 13 I 3. PROPOSED DEVELOPMENT Development Ty pe, Size and Timetable Urban Living Lofts At Magnolia Street 000 The Urban Living Lofts at Magnolia Street is a mixed use project that will include residential loft units and a small area for business use on the first floor facing Magnolia. The timetable identified by the developer is for construction to begin in the fall of 2005, with full buildout anticipated within the next year. Per the Larimer County Urban Area Street Standards, the short-range time horizon used in the analysis is 2010. A conceptual layout of the first floor of the site is shown in Figure 4. Figure 4 Site Plan Hr- 2 Spaces V /I 7- < Bu sine s Sp ce < F7 7 Magnolia Street Page 5 of 13 Hr- 2 Spaces V /I 7- < Bu sine s Sp ce < F7 7 Magnolia Street Page 5 of 13