Loading...
HomeMy WebLinkAbout210-212 W. MAGNOLIA ST., URBAN LIVING LOFTS - PDP - 24-05 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTNorth Star Design, Inc. 700 Automation Drive, Unit I Windsor, CO 80550 i RUNOFF COEFFICIENTS 8 % IMPERVIOUS LOCATION: Urban Living Lofts at Magnolia PROJECT NO: 247-01 COMPUTATIONS BY: PPK DATE: 5/11/05 Recommended Runoff Coefficients from Table 3-3 of City of Fort Collins Design Criteria Recommended % Impervious from Urban Storm Drainage Criteria Manual Streets, parking lots (asphalt) Sidewalks (concrete) Roofs. Lawns (flat <2%, heavy soil), Runoff % coefficient Impervious C 0.95 100 0.95 96 0.95 90 0.20 0 SUBBASIN DESIGNATION TOTAL AREA (ac.) TOTAL AREA (sq.ft) ROOF AREA (sq.ft) PAVED AREA (sq•h) SIDEWALK AREA (sq.ft) LANDSCAPE AREA (sq.ft) RUNOFF COEFF. (C) % Impervious REMARKS EXISTING 0.36 15,750 3029 6332 320 1 6,069 0.66 59 PROPOSED 0.36 15.750 12500 1390 131 1,729 0.87 1 81 'i PROPOSED WI HALF 0.46 E19, 12500 3690 733 2,991 0.84 79 OF MAGNOLIA ' Equations - Calculated C coefficients & % Impervious are area weighted C=E(Ci Ai) /At Ci = runoff coefficient for specific area, Ai a Ai = areas of surface with runoff coefficient of Ci n = number of different surfaces to consider At =total area over which C is applicable; the sum of all Ai's Flow-prelim.xls Cval I this is not a residential living space, this encroachment into the floodplain should be allowed and the new structure will be floodproofed to 18" above the flood plain elevation as required. -nts or need additional information, please call me. North Star �`, design, inc. May 11, 2005 Glen Schlueter City of Fort Collins Stormwatcr 700 Wood Street Fort Collins, CO 80522 Re: Stormwater Requirements for 210 Magnolia Project No: 247-01 Dear Glen,. This letter is in reference to the proposed improvements associated with the Urban Living Lofts at Magnolia located north of Magnolia Street and west of Mason Street in Fort Collins. The site is located in the Old Town Drainage Basin. The site encompasses approximately 0.33 acres (including half of the vacated alley) and currently has a building and parking lot on the site. It is proposed that the existing building will remain and be expanded into additional living units and a parking garage. The parking lot will be removed. The imperviousness for the calculated site was calculated and found to have approximately 9360 square feet of imperviousness and a percent impervious of 59. The proposed condition was also calculated and found to have 13,890 square feet of imperviousness and a percent impervious of 81. When the adjacent street was included in this calculation, the percent impervious went down to 79. These analyses were completed based on the conceptual review comments which indicated that no drainage and erosion control report is necessary if the increase in imperviousness is less than 5000 square feet (this project will increase by 4530 square feet) and if it can be shown that the total imperviousness, including on -half of any adjacent streets or alley, is equal to or less than the master planned imperviousness of - 90%, the report and detention requirements are waived. The building currently exists in the 100 year flood plain. The flood plain elevation at this location is 4994.7 and the existing building finished floor is at elevation 4994.4. The building will be floodproofed to 18" above the flood plain elevation as required. The proposed garage floor is set at 4993.7 which is below the floodplain elevation. Because 700 Automation Drive, Unit I Windsor, Colorado 80550 970-686-6939 Phone • 970-686-1 188 Fax