HomeMy WebLinkAboutFOX MEADOWS BUSINESS PARK NO. 3 REPLAT, TIMBERLINE PLAZA - PDP - 19-05A - SUBMITTAL DOCUMENTS - ROUND 2 - REVISIONS3. On the Illumination Plan, please provide "House Side Shields" for the three
AA fixtures located on the eastern edge of the parking lot. This will help shield
the light source for the homes to the east of the detention pond.
Internal house side shields will be provide on eastern pole lights, Type AA, as requested
in "Comments for Current Planning" note #3.
Please let us know if you have any other issues.
Sincerely,
Sandy McFeron
Project Manager.
V.F. Ripley Associates, Inc.
Mike Oberlander
Project Manager
North Star Design, Inc.
Number.7 Created:911412005
[9114105] Label all fittings, valves and connections on water lines.
Will provide full labeling and details with FCP.
Number.8 Created.911412005
[9114105] Add applicable standard details.
Will provide full labeling and details with FCP.
Department. Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number.1 Created:91912005
[919105] Note - one of the handicap spaces needs to be van accessible and an
overall width of 16ft wide and signed as 'Van Accessible"
A van accessible stall has been added and is signed and dimensioned.
Number.2 Created.91912005
[919105] Please note typical parking stall dimensions, back up distance, aisle
widths.
Dimensions have been added to the stall width, drive isles, sidewalks and landscape
islands.
Comments from Current Planning:
1. Staff is concerned since the source for electrical power is at the immediate
corner of Timberline and Bighorn, that the electrical transformer and electrical
meters will be placed in such a way so as to be highly visible to the public. If
these appurtenances are to be placed in this location, then extra screening
measures are requires. Please consider the use of a solid decorative enclosure
for the screen wall and dense landscaping for the meters that will achieve
screening at the time of maturity. Sufficient landscaping should screen the gas
meters as well.
The electrical transformer has been placed on the south and east side of the building to
the interior of the site. It will not be highly visible from Timberline Road. Refer to site
plan.
2. Please provide a shrub bed at the immediate corner of Timberline and
Bighorn along the sidewalk to prevent corner cutting. Turf in this small isolated
area will be difficult to maintain.
Turf has been removed and replaced with a shrub bed.
40 hour extended detention for any area draining through this detention pond.
The volume of additional detention needed to accommodate this minimal
requirement can be calculated as being part of the existing water quantity
detention, so that this requirement does not become too burdensome on this
property.
Water quality for all areas draining to the pond as well as detention to the appropriate
rainfall are now provided with the proposed excavation in the pond.
Topic: Easements
Number.4 Created.911312005
[9113105] Since Tract B is already platted, the detention area in the existing
facility as well as in the parking lot will need to be dedicated by separate
document. If the easement for part of the detention pond already exists, then
please provide a copy of the easement and a reception number. In that case, only
the proposed detention area that falls outside of the existing easement will then
need to be dedicated as a drainage easement.
See engineering comment 21 — there should be a copy of this easement in the Fox
Meadows file — if there is not, contact North Star Design, Inc.
Topic: Grading
Number. 15 Created. 9/15/2005
[9115105] The plan shows grading onto the sunstone channel to the south. If any
grading occurs within that Tract, approval from the owner of the tract would be
required and a note should be added to indicate that disturbed area will be
restored to equal or better condition.
See engineering comment 22.
Department. Water Wastewater Issue Contact: Roger Buffington
Topic: Landscape plan
Number:9 Created.911412005
[9114105] Show the existing irrigation water service on the landscape plan.
The existing irrigation water service has been added to the landscape plan.
Topic: Utility plans
Number.6 Created.911412005
[9114105] Check with Poudre Fire Authority on required size of fire line. Typically,
6-inch is the minimum size.
A 6" fire line is now shown.
Number.31 Created. 911712005
[9117105] Please make sure plans meet scanning standards specified in Appendix
E-6. This round they look pretty good, except for the black rill.
Acknowledged.
Department: Light & Power Issue Contact. Monica Moore
Topic: General
Number. 12 Created. 911412005
[9114105] Power will come from the oval vault at the intersection of Timberline
Road and Big Horn Drive. Developer will need to coordinate a transformer
location to be located no more than 10-feet from a paved surface and Not within
the City's right-of-way.
Acknowledged.
Number. 13 Created. 911412005
[9114105] Any damage to existing curb, gutter or sidewalk during installation of
electric facilities will be the developer's responsibility to repair and/or replace.
Acknowledged.
Department: Natural Resources Issue Contact: Doug Moore
Topic: General
Number., 10 Created: 911412005
[9114105] None at this time, Doug Moore will visit the site this week to make sure
that there are not any issues with denning fox. Please contact him at (970) 224-
6143 for additional information.
Acknowledged.
Department: Police Issue Contact. Joseph Gerdom
Topic: General
Number: 14 Created: 911412005
[91141051 Malus @ north driveway entrance should be moved back - will require
car over side walk to get adequate site distance.
The trees located at the drive entry/exit to the property have been adjusted to eliminate
any site distance issues.
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Drainage Report
Number.5 Created.911312005
[9113105] The report states that no drainage water quality will be provided as this
was previously done with the Fox Meadows retail development. The City will.
require that the existing outlet structure in the pond be revised to accommodate
Number. 24 Created: 911712005
[9117105] No more than about 750 sq feet of area can drain out the driveway
across the sidewalk. The grading needs to be adjusted so this is accomplished.
A curb cut has been added to keep flows off of the sidewalk.
Number. 25 Created. 911712005
[9117105] Show existing features in dashed or lighter line weight. It is hard to
determine what is existing and what is proposed.
Existing and proposed items have been shown differently (completely redone).
Number. 26 Created. 911712005
[9117105] Need sections for the walls. Do the walls impact the parking stall
depths? Does it impact the drainage pipe placement? The full design of the wall
will need to be provided before the plans are approved.
There are no longer any retaining walls on the project.
Number. 27 Created: 911712005
[9117105] Need to provide stall and isle widths and depths on the site plan.
Dimensions have been added to the stall width, drive isles, sidewalks and landscape
islands.
Number. 28 Created. 911712005
[9/17/05] Identify the width of the sidewalk in front of the parking stalls. It needs
to be a minimum of 6 feet wide.
Dimensions have been added to the sidewalks.
Number. 29 Created: 911712005
[9117105] See plans for additional comments.
Acknowledged.
Number. 30 Created. 911712005
[9117105] See utility plan check sheet.
Acknowledged.
Number..17 Created. 911712005
[9117105] The driveway should line up with the driveway across the street or meet
separation requirements. Needed prior to hearing.
A variance for 10' of CL separation was requested on 3-15-06 and granted (per an
email from Sheri) on 4-4-06.
Number., 18 Created. 911712005
[9117105] Add the following note to the utility sheet: Limits of street cut are
approximate. Final limits are to be determined in the field by the City Engineering
Inspector. All repairs to be in accordance with City street repair standards.
The note has been added.
Number: 19 Created. 9/17/2005
[9/17/05] Label that the driveway is to be concrete to the property line
The label has been added.
Number. 20 Created. 911712005
[9117105] Identify distance the driveway is located from the property line and the
width of the driveway.
The dimension has been added.
Number. 21 Created. 911712005
[9/17/05] Is the detention pond easement existing? It was not dedicated on the
plat, so if it is existing provide reception number for the easement on the plans. If
it does not exist then it will need to be dedicated by separate document.
The easement was dedicated and recorded at reception number 99072717.
Number: 22 Created. 911712005
[9117105] Offsite grading to the south is shown. If this property is owned by
stormwater then no letter of intent is needed, but if it is not then a letter of intent
to grant easement to do the grading work shown is needed prior to hearing.
The new design requires no off site grading. The land to the south (Sunstone Swale) is
owned by the City (FYI).
Number. 23 Created: 911712005
[9117105] The area within the parking lot out of the currently labeled detention
pond that is needed part of the pond will need to be dedicated as a drainage
easement by separate document.
There is no longer any parking lot detention.
V Fr1iipI49yABBCCIATE9 INC
Landscape Architecture Urban Design Planning
April 19, 2006
Mr. Ted Shepard
Fort Collins Planning Department
281 North College Avenue
Fort Collins, CO 80524
RE: Fox Meadows Business Park, Track B, formerly known as Colorado Health
& Fitness Center PDP and renamed to Timberline Plaza PDP — TYPE H
Response to staff Project Review comments
Dear Mr. Shepard:
We have reviewed the staff letter dated September 19, 2005 and have the following
comments:
ITEM: Request for a convenience shopping center containing:
• retail
• office, financial services and clinics
• fast food restaurants, no drive-in
• no auto -related uses
COMMENTS:
Department: Engineering Issue Contact: Sheri Wamhoff
Topic: General
Number., 16 Created. 911712005
[9117105] Will need signature blocks on all sheets on the lower right corner
(except the existing plat).
Blocks will be added at FCP.
Phone 970224.5828 Fax 970.224.1662
401 West Mountain Ave. Suite 201
Fort Collins, CO 80521-2604
vfripley.com