Loading...
HomeMy WebLinkAboutFOX MEADOWS BUSINESS PARK NO. 3 REPLAT, TIMBERLINE PLAZA - PDP - 19-05A - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEW18". In addition, this project will replace the WQ outlet structure, built per the 1999 Lund study, with one meeting current standards. 6. Acknowledged. As the Preliminary Utility Plans show, utility service taps are being proposed off of the mains situated in Bighorn. 7. Acknowledged. 8. A fire hydrant currently exists directly adjacent to the northwest comer of the proposed building. While its working pressure at 1,500 gpm is not currently known, it is anticipated that it will not present a problem. This information will be verified prior to the final submittal of this project. 9. Fire access is being provided. 10. Acknowledged 11. A Transportation Impact Study is being submitted. 12. Acknowledged. 13. While the recorded plat for Fox Meadows Business Park does show a 15' utility easement along the Timberline right of way, the right of way width is only 70' (section line to eastern right of way line). An additional 0.5' of right of way will be dedicated to the City, and the 15' utility easement adjusted 0.5' to the east, prior to construction.. 14. Acknowledged. 15. Acknowledged, see site plan and civil drawings. 16. Acknowledged, see site plan and civil drawings. 17..Acknowledged. 18. Acknowledged. 19. Acknowledged. 20. Bike parking is provided 21. There is a sidewalk connection designed from Bighorn to the entrance. 22. Acknowledged. 23. Acknowledged 24. Acknowledged. 25. A neighborhood meeting has been held.. . 26. Acknowledged. 27. Area has been provided for recyclable material containers within the trash enclosure. Thank you for your consideration, Sincerely, Amy C. Johnson VF Ripley Associates August 23, 2005 Ted Shepard City of Fort Collins 281 North College Avenue P.O. Box 580 Fort Collins, CO 80521-0580 RE: Response to Conceptual Review comments for Colorado Health and Fitness Center Dear Ted, The responses below address the comments raised by the Conceptual Review Team regarding the Colorado Health and Fitness Center. 1. Acknowledged. 2. The estimated maximum rated capacity for this facility is approximately 470 persons. 117 parking spaces are being provided per the suggested guideline of using' one space per four persons maximum rated capacity. The parking lot is designed to be sufficiently screened and landscaped. 3. Acknowledged. 4. Acknowledged. 5. Acknowledged. 6a. The existing detention facility, in the eastern portion of Tract B, was originally designed in 1990 by Stewart & Associates. The Lund Partnership redesigned the pond in 1999 so as to include water quality.capture volume for the entire 15.2 acre, Fox Meadows project. Since the currently proposed land use, and imperviousness, of Tract B is no different from that projected in the 1999 WQCV calculations, the developer of this project should not be required to provide additional storage for this purpose. This however, is not the case with the detention volume. While the 1999 study increased the ponds size to accommodate WQCV, it did not increase the ponds detention volume to reflect the most recent intensity -duration - frequency curve. Therefore, as part of this project, the total detention volume will be increased by applying the most recent IDF curve to the developable portion of Tract B (the remainder of the original 15.2 acre site has been grandfathered using the old IDF curve). As the Preliminary Drainage Report for this project shows, the larger detention volume has been further increased to account for two onsite basins that drain offsite undetained. This increased detention volume will be accommodated within an onsite parking lot facility having a maximum depth of