Loading...
HomeMy WebLinkAboutEVANGELICAL LUTHERAN GOOD SAMARITAN, NEXTEL WTE - PDP/FDP - 33-05 - CORRESPONDENCE - (5)44 Sincerely, Shelby Sommer Associate City Planner Page 3 Number: 4 Created: 8/29/2005 [8/29/05] Load requirements and meter location have already been coordinated with Light and Power. Refer to Non W.O. #2714 Department: Natural Resources Issue Contact: Doug Moore Topic: General Number: 2 Created: 8/25/2005 [8/25/05] The Construction Timing standard 3.4.1(N)(4) will apply to this project due to the presence of a communal Ferruginous Hawk winter night roost site locate adjacent to the east side of the site. Construction may not occur during the roosting season which occurs from October 15 thru March 15. Please note this construction timing constraint on the site plan or under construction notes on the utility plans. Timing constraint may also be placed as a condition of approval for the project and will be included in a development agreement if an agreement is required. No other issues. Contact Doug at 224-6143 or dmoore@fcgov.com. Department: Transportation Planning Topic: General Number: 7 [8/30/05] No Comments Department: Zoning Topic: zoning Number: 1 Issue Contact: Kurt Ravenschlag Created:8/30/2005 Issue Contact: Peter Barnes Created: 8/17/2005 [8/17/05] Section 3.8.13(C)(3) requires the antennae to be screened. If that's possible to do, then the screens need to be shown. Please revise your plans, taking into account the aforementioned comments. When you are ready to submit your revisions, please contact me at (970) 221- 6750 to schedule a submittal appointment. You should submit the following items: • Site/elevation plan sets - 8 copies • Written response to City comments - 8 copies If you have any questions regarding these issues or any other issues related to this project, please feel free to call or email me. Page 2 Sef 61/2/65 t0 )ef. Mid@ neXK) -OW-) STAFF PROJECT REVIEW City of Fort Collins JEFF KEITH Date: 09/02/2005 NEXTEL 333 INVERNESS DR. SOUTH ENGLEWOOD, CO 80112 Staff has reviewed your submittal for EVANGELICAL LUTHERAN GOOD SAMARITAN, NEXTEL WTE - TYPE II, and we offer the following comments: ISSUES: Department: Current Planning Topic: 6enerol Issue Contact: Shelby Sommer Number: 5 Created: 8/30/2005 [8/30/05] All wireless telecommunication equipment shall be located as far from the edge of the roof as possible. (Section 3.8.13(C)(3)). Number: 6 Created:8/30/2005 [8/30/05] Roof- and ground -mounted wireless telecommunication equipment shall be screened by parapet walls or screen walls in a manner compatible with the building's design, color and material. (Section 3.8.13(C)(3)). Please screen antennae as much as possible. Number: 8 Created: 8/31/2005 [8/31/05] Rick Lee of the Building Department (221-2340) requests that you provide structural design to resist 100 MPH exposure "B" wind load. Number: 9 Created: 8/31/2005 [8/31/05] Technical Services indicated that the lines on the plans could be darker for better readability/scanability. Department: Light & Power Topic: General Number: 3 Issue Contact: Alan Rutz Created:8/29/2005 [8/29/05] On the cover sheet T1, Power provider is listed as Xcel. Power will be supplied by Ft Collins Utilities. Page 1