Number: 36 Created: 10/ 18/2005
[ 10/ 18/051 Provide access ramps for handicap parking stall located near
playground.
Department: Zoning Issue Contact: Peter Barnes
Topic: Zoning
Number: 3 Created: 10/ 11 /2005
[ 10/ 11 /05) There needs to be a note on the Cover Sheet (sheet 1 of 6) to the
effect that this is a qualifying affordable housing project.
Number: 4 Created: 10/ 11 /2005
[ 10/ 11 /05) A 6' high solid fence is required along the parking areas on the
south side of the lot. There's a note on the site plan showing an "existing
fence ® south property line", but it's unclear how tall that fencing is, and if
It's all along the south lot line. If it's all along the south lot line, then a note
should be added stating that in the event the homeowners to the south
remove their fence, then the developer or HOA will be responsible for
constructing a fence to screen the parking spaces as required.
Number: 5 Created: 10/ 11 /2005
[ 10/ 11 /05) A 5' wide landscape strip is required along the east lot line
adjacent to the driveway and 3 parking spaces unless the driveway will also
provide access to the future commercial phase on Lot 2. If A will provide
such access, then a note to that affect should be on the plan.
Number: 6 Created: 10/ 11 /2005
[10/11/051 Section 3.5.2(D)(1) requires a minimum building setback of 30'
from the ROW of an arterial street. It appears that the building setback
along the Taft Hill ROW is less than that.
Number: 7 Created: 10/ 11 /2005
[10/11/051 Where is bicycle parking going to be provided?
This item has been scheduled for the November 17, 2005 Planning &
Zoning Board public hearing, concurrent with the Innovation Island, ODP.
The ODP will be heard first, followed by this PDP.
It is not necessary to re -submit plans based on these comments before
going to public hearing on November 17th. They can be addressed with the
Final Compliance submittal. Please check with me for submittal
reauirements Drior to submitting Final Compliance Dlans. Be sure and
return all red -lined plans if/when you re -submit.
Page 7
Topic: Grading the swale along the south property line looks to very
close to the edge of
Number: 29 Created: 10/ 17/2005
[10/ 17/051 The swale on the south side of Building B looks very tight,
please provide a cross-section at that location verifying that the proposed
grading will work for that area.
Topic: Sewer
Number: 38 Created: 10/ 18/2005
[10/18/051 Please relocate sanitary line to avoid water quality outlet
structure.
Since the landscaping in the Woodridge HOA tract will be disturbed during
boring operations, please add a note stating that the landscaping will be put
back to an equal or better condition to what it was before construction
operations.
Please make sure that the sanitary line has a minimum 4 feet of cover as it
crosses under the proposed water quality pond.
Topic: Water
Number: 37 Created: 10/ 18/2005
[10/18/051 Please call out all water lines appurtenances: valves, thrust
blocks, swivel Ts, curb stops, meter pits etc...
It is suggested that a 6 " line be used to serve Buildings D and E. Please
use a valve to isolate that line from the rest of the development.
Call out all existing water lines, call out which ones are district and which
ones are City.
Department: Traffic Operations Issue Contact: Eric Bracke
Topic: Trgffiic Engineering
Number: 8 Created: 10/ 12/2005
[ 10/ 12/051 The access onto Taft Hill Road is to be an emergency access
ONLY. Please have the access blocked off with bollards.
Department: Transportation Planning Issue Contact: Hurt
Ravenschlag
Topic: Technical Services
Number: 34 Created: 10/ 18/2005
[ 10/ 18/051 Walkways should be 6' in width if attached to driveway.
Number: 35 Created: 10/ 18/2005
[ 10/ 18/051 A direct walkway needs to be provided to connect building D
with play area to eliminate the two drive way crossings as currently shown.
Page 6
Department: Light & Power Issue Contact: Doug Martine
Topic: Landscape plan
Number: 1 Created: 10/7/2005
[10/7/05] There is an existing streetlight on Taft Hill Rd., approximately 20
ft. south of this site. The location of the most southerly street tree will need
to be adjusted to provide a minimum of 40 ft clearance between the light
and the tree. As an alternative, the tree could be changed to an ornamental
type which requires only a 15 ft. clearance.
Department: Natural Resources
Topic: General
Number: 2
[10/7/05] No issues.
Issue Contact: Doug Moore
Created: 10/7/2005
Department: PFA Issue Contact: Michael Chavez
Topic: General
Number: 41 Created: 10/ 19/2005
[10/19/051 Emergency Access Easement: The private drive shall be platted
as a "Emergency Access Easement" on the final Plat.
Number: 42 Created: 10/ 19/2005
[ 10/ 19/051 Addressing: Unit and Building address shall be posted on both
sides of the buildings. (Sidewalk side & garage side).
Number: 43 Created: 10/ 19/2005
[ 10/ 19/051 Water Supply: Fire hydrant locations are approved. Fire
hydrant flow shall be 1500 gpm w/20 psi residual.
Number: 44 Created: 10/ 19/2005
[ 10/ 19/051 This project will NOT require the use of Fire Sprinklers.
Department: Stormwater Utility. Issue Contact: Basil Hamdan
Topic: Drainage
Number: 28 Created: 10/ 17/2005
[10/ 17/05] In order to minimize the amount of untreated flows coming off
the site, please add a note to the grading plans stating that all downspouts
from the Building A along Harmony will be directed to the south.
Topic: Drainage Report
Number: 30 Created: 10/ 17/2005
[ 10/ 17/05] Good job on the written portion of the report explaining the
design constraints that controlled the design of the stormwater facilities for
this site. Thanks.
Page 5
Number: 23 Created: 10/ 14/2005
[ 10/ 14/051 It appears that some utilities are not located in easements.
(addressed at meeting)
Number: 24 Created: 10/ 14/2005
[ 10/ 14/051 Please show existing offsite grades for a minimum of 50',
including the neighborhood to the south. Will any offsite grading be
necessary? If so, we need a letter of intent from the owner prior to hearing.
(FC)
Number: 25 Created: 10/ 14/2005
[ 10/ 14/05) Please show all features 150' min offsite, including existing
structures on the north side of harmony. (FC)
Number: 26 Created: 10/ 14/2005
[ 10/ 14/05) You are showing an outer curve radius of 30' in an emergency
access lane. The minimums required by PFA are 25' inner, 50' outer.
Please revise. (addressed- accepted by Ron Gonzales)
Number: 27 Created: 10/ 14/2005
[ 10/ 14/051 Please refer to redlines for additional comments and revisions
Number: 39 Created: 10/ 19/2005
[ 10/ 19/051 All newly installed sidewalks are to be 6" minimum thickness.
You are showing our old details with 4". Please revise per Standard
Drawing 1601.
Number: 40 Created: 10/ 19/2005
[10/19/051 Add standard street cut note: "Limits of street cut are
approximate. Final limits are to be determined in the field by the City
Engineering Inspector. All repairs to be in accordance with City street
repair standards."
Topic: Technical Services
Number: 31 Created: 10/ 18/2005
[ 10/ 18/051 Tech. services comment: See typo in title
Number: 32 Created: 10/ 18/2005
[ 10/ 18/051 Tech. services comment: Please show how Taft Hill & Harmony
were dedicated.
Number: 33 Created: 10/ 18/2005
[ 10/ 18/051 Tech. services comment: Is all of Lot 1 a
Utility/Drainage/Private Access easement? Note on Sheet lis confusing.
(Where will the structure be placed on Lot 1?)
Page 4
Number: 15 Created: 10/ 14/2005
[10/14/051 The line type used for curb& gutter should be solid- please
revise. (FC)
Number: 20 Created: 10/ 14/2005
[10/ 14/051 Remove the landscape layer from all utility plan sheets. (FC)
Topic: General
Number: 9 Created: 10/ 14/2005
110/ 14/051 Reference the nearest 2 benchmarks on the cover sheet. It
appears you are only referencing 1. (FC)
Number: 13 Created: 10/ 14/2005
[ 10/ 14/051 You will need to provide a turnaround area for the parking
spaces to the south since there is no real continuity there.
Number: 14 Created: 10/ 14/2005
[10/14/051 Please indicate a PFA approved barricade on your plans to
prevent public use of the Taft Hill access. (Detail for FC)
Number: 16 Created: 10/ 14/2005
[ 10/ 14/051 Please label and dimension all existing and proposed ROW.
Number: 17 Created: 10/ 14/2005
[10/14/051 Show concrete to the back of ROW for all proposed curb cuts
(label and hatch)
Number: 18 Created: 10/ 14/2005
[10/14/051 Please modify your sight distance easement variance request to
account for the added lane of traffic that must be crossed for the left turn.
The value you got from AASHTO is based off of a two-lane street.
Number: 19 1 Created: 10/ 14/2005
[10/14/051 Provide conduit for future undergrounding of overhead lines on
SW side of the site- this should be shown and labeled on the plans.
Number: 21 Created: 10/ 14/2005
[ 10/ 14/051 Are structures shown on the south side of the site retaining
walls? If so, label and provide a detail. If not, what are they? (FC)
Number: 22 Created: 10/ 14/2005
[ 10/ 14/051 What is the honeycomb type hatching shown in the access on
the grading plan? (FC)
Page 3
Delivery Agreement must be in place prior to any delivery of mail. Contact
Carl Jenkins, Growth Coordinator, U.S/. Postal Service, 301 East
Boardwalk Drive, Fort Collins, CO., phone #970-225-4130, cell #970-214-
3668, fax #970-225-4139.
Topic: Landscape plan
Number: 46 Created: 10/24/2005
[ 10/24/051 Tim Buchanan, the City Forester, indicated that, on the Final
Compliance Landscape Plan, the applicant must directly label the trees so
that species can be identified. 4
Topic: Site Plan
Number: 49 Creat d: 10/24/2005
[10/24/051 How will the proposed "emergency acce�s" drive at the
southwest corner of the development be controlled,
Number: 50 Created: 10/24/2005
110/24/051 Two types of fencing are being proposed but the plan is unclear
as to where the fences will actually be. Pleas expand this information on the
Site and Landscape Plans.
Number: 51 Created: 10/24/2005
[10/24/051 There is a required sight distance easement along West
Harmony Road that must be shown on the development plans (plat, Site
Plan, Landscape Plan).
Number: 52 Created: 10/24/2005
[ 10/24/051 The only bicycle rack shown on the Site Plan is at the
playground area. Is it safe to assume that all of the residents will park
bicycles in their attached garages?
Department: Engineering Issue Contact: Dan
DeLaughter
Topic: format
Number: 10 Created: 10/ 14/2005
[ 10/ 14/05] Please be sure all line types are differentiable.
Number: 11 Created: 10/ 14/2005
[ 10/ 14/05] A legend must be included on each sheet, not just on one. (FC)
Number: 12 Created: 10/ 14/2005
[ 10/ 14/051 There are a few scanability issues- please refer to redlines for
comments, and refer to Appendix E-6 of LCUASS for scanability
requirements. (FC)
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
Fort Collins Habitat For Humanity, Inc. Date: 10/24/2005
c/o Vignette Studios - Don Tiller
144 North Mason Street, Suite 2
Fort Collins, CO 80524
Staff has reviewed your submittal for INNOVATION ISLAND, FIRST
FR NG, PDP - TYPE 1, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Building
Number: 47 Created: 10/24/2005
[10/24/051 Rick Lee of the Building Department offered the following
comments:
a. He is providing a copy of the Codes & Standards that his department
will enforce. As stated on that sheet, there is a requirement to schedule
a pre -submittal meeting with the Building Department.
b. Provide accessibility per State Statute (CRS 9-5) and 1998 ANSI.
Please contact Rick, at 221-6760, if you have questions about these
comments.
Topic: General
Number: 45 Created: 10/24/2005
[10/24/051 Doug Moore of the Natural Resources Department indicated
that, after visiting the site, he has determined that neither an Ecological
Characterization Study or a Wetland Delineation will be required for this
development proposal.
Number: 48 Created: 10/24/2005
[ 10/24/051 Carl Jenkins of the Unites States Postal Service indicated
that mail service must be provided by a centralized delivery using a
minimum of 3 centralized box units (CBU's, 2 Industry Type III and 1 Type
1). Please revise the plan to show the required CBU locations as approved by
the U.S. Postal Service. In. all cases the CBU's must be located in the public
right -of --way or a designated easement. Please be advised that the
responsibility of purchasing and maintaining the CBU's with the concrete
pads is that of the owner/developer/builder/HOA. Prior to occupancy
within the development approved mail receptacles must be in place. A
Page I