HomeMy WebLinkAbout4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - 3-06 - CORRESPONDENCE - (7)If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, ��Ibq && w LC Shelby Sommer Associate City Planner Page 3 [4/7/06] Remove the note 'This is a land use planning document...." No civil drawings are being submitted so this note is not correct. Number: 48 Created: 4/7/2006 [4/7/06] Add a note: See Appendix E1 and E2 of the Larimer County Urban Area Standards for other requirements. Number: 50 Created: 4/19/2006 [4/19/06] From Technical Services: None of the symbols for trees and shrubs are dark enough to scan to file. See Appendix E6 for scanning requirements. Department: PFA Issue Contact: Carie Dann Topic: fire Number: 28 Created: 2/28/2006 [4/19/061 Our map shows the closest fire hydrant at the southeast comer of College Avenue and Fairway Lane. Applicant needs to determine this hydrant meets minimum flow requirement. [2/28/061 Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Spacing and flow requirements for commercial property are 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter. Department: Transportation Planning Issue Contact: Kurt Ravenschlag Topic: General Number: 51 Created: 4/19/2006 [4/19/06] No further comments. Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Stormwater Number: 38 Created: 3/1/2006 [4/17/06] The provided water quality outlet detail needs to be revised. As currently shown, the water quality pond will hold water up to 2 inches deep before it releases. Please make sure that the plate has an opening at the invert elevation of the pond. According to Urban Drainage criteria, rows need to be separated by 4 " in order to use that manual's charts. If no utility plans are being submitted, then how will the change to the pond outlet be documented. Maybe a note on the site plans referencing the drainage design documents would be appropriate. [3/1/06] The original detention area did not have a water quality component. Since the pond is already built and landscaped, no new detention will be required, however, it is requested that the pond outlet, be modified to include a water quality plate and detention. A variance will be approved to account for the water quality volume as being part of the quantity volume. Please provide water quality calculations. Be sure and return all of your redlined plans when you re -submit. Page 2 i� STAFF PROJECT REVIEW City of Fort Collins VF RIPLEY ASSOCIATES, INC. Date: 04/24/2006 401 WEST MOUNTAIN AVE. SUITE 201 FORT COLLINS, CO 80524 Staff has reviewed your submittal for 4900 SOUTH COLLEGE AVENUE PDP, CHANGE OF USE - TYPE II, and we offer the following comments: ISSUES: Department: Current Planning Topic: General Number: 49 Issue Contact: Shelby Sommer Created: 4/17/2006 [4/17/06] Is any additional lighting proposed? If so, please indicate where and what type. See lighting standards in LUC Section 3.2.4. If not, please place a note indicating such on the site plan. Department: Engineering Issue Contact: Susan Joy Topic: Easement Dedications Number: 45 Created: 4/7/2006 [4/7/06] The 20' access easement dedication was incorrectly submitted and needs to be resubmitted using the UNALTERED City template. The exhibit and legals for this easement were checked and accepted. OK to submit signed and wetstamped does from the surveyor along with a $250 filing fee made out to the City of Fort Collins. Larimer County filing fees also apply and that amount will be calculated once all the paperwork is received. Topic: General Number: 15 Created: 2/28/2006 [4/5/06] Just keeping this comment in for coordination and papertrail. [2/28/06] The City will not require any upgrades to the existing sidewalk along either the frontage road or Fairway. This project will only have to replace and/replace any existing damaged curb, gutter, ramp and/or sidewalk. li!I7 ,7197 ii R Created: 2/28/2006 [4/5/06] Easement dedications are still not correctly labeled on the plan (the frontage road sidewalk access easement is not shown). [2/28/06] Please label and dimension all existing easements as "existing" and all proposed easements as "proposed". Must provide legals and exhibits of all easements to be dedicated with the next submittal along with a $250 processing fee for each dedication. Larimer County filing fees are due prior to the actual filing of the dedications. Number: 25 Created: 2/28/2006 [4/5/06] Label the dimensioned stalls as "typical" if typical and dimension all atypical stalls. See redlines. [2/28/06] Please dimension all parking stalls, driveway widths and drive aisles. Number: 44 Created: 4/5/2006 [4/5/06] Please provide handicapped ramps for the handicapped parking stalls. Number: 47 Created: 4/7/2006 Page 1