Loading...
HomeMy WebLinkAboutTHE MEADOWS PUD - PRELIMINARY - 50-89A - - STAFF'S PROJECT COMMENTSDevelo• nt Services • Planning Department City of Fort Collins November 14, 1989 Dick Rutherford Stewart and Associates 214 N. Howes Street Fort Collins, CO 80521 Dear Dick: Staff has reviewed the Seneca PUD Master Plan and The Meadows PUD Preli- minary Plan and has the following comments to make: Seneca PUD Master Plan Utility mains should be included as part of the master plan. A 12" water main exists in Seneca Street. The mains needed to serve this development will have to connect to this existing water main. 2. The nearest sewer main is in Shields Street, 2400 feet south of Horsetooth Road. This sewer main must be extended to serve this site. Repay agree- ments will be drawn up to benefit the developer of this site (see item #10 below). 3. A master drainage plan is required as part of the PUD master plan submit- tal. A regional detention pond is master planned for this area, but no documentation or report verifies the required volume of 14 acre-feet. It appears that the 3.75-acre site for this detention pond may not be ade- quate, since at this stage, there is no consideration for freeboard requirements or an actual stage -discharge curve to verify the adequacy of the pond. 4. A future pedestrian trail should be shown along the west side of the Pleasant Valley and Lake canal. 5. Further information regarding the potential connection to Imperial Estates will be provided by staff; however, at this time, it appears that this connection should be pedestrian, rather than vehicular in nature. 6. The following information needs to be added to the master plan: - parcel size; - existing zoning; - maximum height of all structures; - 150' information to the north and south of this site; - note regarding the intent of a master plan (see attached copy); and - provide adequate owner signature block area for all property owners of record. 300 LaPorte A%,enue - P.O. Box -80 • Fort Collins, CO 80522-O580 • (303) 221-67:;0 0 • 7. A neighborhood meeting has not previously been required by staff; how- ever, with the submission of a master plan and the potential for some type of access to Imperial Estates, a neighborhood meeting must be held. 8. A traffic study, addressing both the master plan and the preliminary plan must be submitted. Rick Ensdorff, Transportation Director, should be contact to verify the extent and content of this study. The Meadows PUD Preliminary 9. Light and Power has existing underground electric on the north side of Horsetooth. The applicant will be responsible for normal Light and Power development charges, plus costs to install_ a temporary electric system from Horsetooth_ to the site. _ The applicant will need to provide an--off-site easem nene t for this line. Phase I will need to consist of Lots 4, 5 and 6 for electrical service to be provided. Curb and gutter will be required on Clear Meadow Court in Phase I as described in the attached Electrical Construction Policies, Practices and Procedures pamphlet. 10. A 12" water main is existing in the proposed Seneca right-of-way. The water main to serve this subdivision must connect to the existing 12" main. A stub is existing near the alignment of Clear Meadow Court. If the stub can be used, do so. If it isn't aligned properly, it must be abandoned at the main. 11. The nearest sewer main is located on Shields Street, approximately 2400' south of Horsetooth Road. This main must be extended to the proposed subdivision. The alignment of the sewer main will determine road align- ment between Shields and Seneca Streets. Repay agreements for the sewer main will be available for the developers who build this main. This sewer extension is being required because this proposal is for a subdivision, rather than for two "estate" lots (see Conceptual Review comments dated August 28, 1989) as was previously indicated to the Water and Wastewater Utility. 12. A minimum 8' wide utility easement adjoining the west line of Seneca from Horsetooth Road south to the end of the platted street must be dedicated. 13. A preliminary drainage report is required. 14. A regional detention pond is proposed on 3.75 acres of the master plan. The Foothills Basin master plan identifies a need for 14 acre-feet of storage, which cannot be accomplished in this size of pond. The detention volumes would be verified during final design and in the drainage report. The cost of design is reimbursable, but it is the responsibility of the applicant until a development agreement is entered into which authorizes a reim- bursement. YieAny existing vegetation should be shown on the site plan. 16. A 25' recreational trail easement should be provided along the Pleasant Valley and Lake Canal. 0. A site plan must be submitted (or this plan may substitute as both a site plan and preliminary plat). The plat must indicate the square footage of each lot. 18. An 80' diameter turnaround must be platted with the temporary access easement. This access must be constructed with a roadbase section ade- quate to hold fire equipment. 19. The temporary access easement will remain until access is taken off of improved Seneca. ,,20. The proposed driveway should be separated farther from the Seneca inter- section with Horsetooth. �_;A. The bend in Clear Meadow Court should be designed as a 90 degree turn. 22. The preliminary utility plans should show all PUD improvements, rather than just those for Phase I. The final utility plans should show all improvements, with the specific phase improvements identified. 23. An indication that off -site access easements for utilities and access are obtainable must be provided. 24. A preliminary soils report must be submitted. 25. A preliminary landscape plan, indicating the proposed treatment along Seneca (which is a collector street) needs to be provided. This plan should address landscaping, as well as any fencing planned for the development. Of particular interest, is fencing treatment for Seneca at the backs of lots. 26. The following information needs to be added to the site plan/plat: - 150' information; - existing zoning; and - maximum building height. 27. The proposed access road exceeds 660' from a single point of access. Either an approved second point of access must be provided, or the homes beyond 660' must be provided with residential fire sprinkler systems. 28. A fire hydrant must be provided, which is accessible to both lots from the temporary access road. This project was an incomplete submittal, with no storm drainage report/plan, traffic study or soils report being submitted. This information is very critical to the overall configuration of the master plan (particularly with respect to the configuration of the proposed regional detention pond) and is important to the review of the preliminary plan, as well. Therefore, both the Seneca Master Plan and The Meadows PUD Preliminary are being continued to the January 22, 1990 Planning and Zoning Board. During the intervening time period, a neighborhood meeting will be scheduled and held. The missing information needs to be submitted as soon as possible (but no later than December 4, 1989) so that these items may be placed on the January 22, 1990 Board agenda. If you have questions or comments regarding this letter, please do not hesitate to contact me. Sincerely, Sherry Albertsein-Clark, AICP Senior City Planner cc. Mike Herzig, Development Coordinator f ile