Loading...
HomeMy WebLinkAboutSAMS CLUB FUEL STATION - MJA200002 - - PHOTOMETRIC PLAN (2)LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 1/4 Rev. 10/19/20 SPEC.1020.A.0420 Catalog #:Project: Date:Type:Prepared By: Scottsdale® Legacy (CRUS) LED Canopy Luminaire FEATURES & SPECIFICATIONS Construction • Features a ultra-slim 11/16” profile die-cast housing, with flat clear tempered glass lens. Unit is water-resistant, sealed and IP66 rated. Integral designed heat sink does not trap dirt and grime, ensuring cool running performance over the life of the fixture. • Standard color is white and is finished with LSI’s DuraGrip® polyester powder coat process. DuraGrip withstands extreme weather changes without cracking or peeling. • Luminaire assembly incorporates a pressure stabilizing vent breather to prevent seal fatigue and failure. Optical System • Features an array of select, mid-power, high brightness, high efficiency LED; 3000K, 4000K, 5000K color temperature, 80 CRI (nominal). • Choice of Symmetric or Asymmetric distribution. Asymmetric provides a wider distribution pattern. • Six Lumen Packages: 5,000, 9,000, 10,000, 13,000, 18,000 and 22,000 Lumens. Electrical • High performance factory programmable driver features over-voltage, under voltage, short-circuit and over temperature protection with integral 6kV surge protection that meets IEEE C62.41.2 and ANSI C82.77-5 Location Category C Low standards. Custom lumen and wattage packages available. • Additional field replaceable 10kV surge protection device that meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2) is standard. • Driver components are fully encased in potting for moisture resistance. Complies with IEC and FCC standards. 0-10 V dimming supplied standard with all drive currents. • Die-cast aluminum, wet location rated driver/electrical enclosure is elevated above canopy deck to prevent water entry, provide easy “knock-out” connection of primary wiring and acts as the primary heatsink ensuring cool operation of internal components for longer life. Seals to optical housing via one-piece molded silicone gasket. • Universal voltage power supply, 120-277 VAC, 50/60 HZ and 347-480 VAC, 50/60 HZ input. • -40°C to 55°C (-40°F to 131°F) ambient operating temperature. (Varies based on lumen package and mounting style see performance data for specifics.) • Minimum 60,000 to 100,000 hours depending upon the ambient temperature of the installation location (see performance data for specifics.) Hazardous Location • Designed for lighter than air fuel applications. Product is suitable for Class 1 Divisions 2 only when properly installed per LSI installation instructions. See lsicorp.com for specific guidance. Not available on SLW. Installation • One-person installation. • Installs in a 12” or 16” deck pan. Deck penetration consists of a 4” hole, simplifying installation and water sealing. Unit is designed to quickly retrofit into existing Scottsdale (4”) hole as well as openings for Encore and Encore Top Access and to reconnect wiring for the SC/ECTA without having to relocate the conduit. • Retro panels are available for existing Encores as well as kits for recessed and 2x2 installations (see separate spec sheets). Support brackets are provided standard, to prevent sagging of deck. Warranty • LSI LED fixtures carry a 5-year warranty (contact your LSI representative for extended warranty options.) Listings • UL and ETL listed to UL 1598, UL 8750 and other U.S. and International safety standards. Suitable for wet locations. • DesignLights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights. org/QPL to confirm which versions are qualified. • Meets Buy American Act requirements. • IDA compliant with 3000K or lower color temperature. OVERVIEW Lumen Package 5,000 - 22,000 Wattage Range 38 - 152 Efficacy Range (LPW)114 -156 Weight lbs(kg)23 (10.4) QUICK LINKS Ordering Guide Performance Photometrics Dimensions IP66 LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 2/4 Rev. 10/19/20 SPEC.1020.A.0420 Type: Scottsdale® Legacy LED Canopy Luminaire (CRUS) ORDERING GUIDE Back to Quick Links Prefix Distribution Light Source Drive Current Color Temp Input Voltage Finish Options CRUS - LED Canopy Luminaire SC - Symmetric AC1 - Asymmetric LED SLW - Super Low Watt VLW - Very Low Watt LW - Low Watt SS - Super Saver HO - High Output VHO - Very High Output Custom Lumen Packages3 50 - 5,000K 40 - 4,000K 30 - 3,000K UE - Universal Voltage (120 - 277V) HV - High Voltage 347 - 480V WHT - White BRZ - Bronze BLK - Black HL2 - Hazardous Location TYPICAL ORDER EXAMPLE:CRUS SC LED SS 50 UE WHT FOOTNOTES: 1. AC distribution utilizes a reflector which alters the look from a standard SC distribution. 2. Not available on SLW. PERFORMANCE Back to Quick Links Recommended Lumen Maintenance1 CRUS VHO Ambient Temp C Initial 2 25k hr 2 50k hr 2 75k hr 3 100k hr 3 0 C 102%97%92%88%84% 10 C 102%97%92%88%84% 20 C 102%97%92%88%84% 25 C 102%97%92%88%84% 30 C 102%97%92%88%84% 40 C 101%95%90%85%80% 50 C 101%94%89%83%78% OPERATING TEMPERATURE LUMEN PACKAGE MOUNTING Max VHO Metal/Wood Canopy 45 C HO Metal/Wood Canopy 45 C SS Metal/Wood Canopy 55 C Recommended Lumen Maintenance1 CRUS SS Ambient Temp C Initial 2 25k hr 2 50k hr 2 75k hr 3 100k hr 3 0 C 102%97%92%88%84% 10 C 102%97%92%88%84% 20 C 102%97%92%88%84% 25 C 102%97%92%88%84% 30 C 102%97%92%88%84% 40 C 102%97%92%88%84% 50 C 101%95%91%86%82% DELIVERED LUMENS Lumen Package Distribution 3000K CCT 4000K CCT 5000K CCT WattageDelivered Lumens Efficacy BUG Rating Delivered Lumens Efficacy BUG Rating Delivered Lumens Efficacy BUG Rating VHO SC 21301 140 B4-U0-G2 21835 144 B4-U0-G2 22697 150 B4-U0-G2 152AC17355114B3-U0-G3 17799 117 B3-U0-G3 18502 122 B3-U0-G3 HO SC 17889 143 B3-U0-G1 18346 146 B3-U0-G2 19071 152 B4-U0-G2 125AC14582116B3-U0-G2 14955 119 B3-U0-G2 15546 124 B3-U0-G2 SS SC 13113 141 B3-U0-G1 13449 144 B3-U0-G1 13980 150 B3-U0-G1 93AC11468123B3-U0-G2 11761 126 B3-U0-G2 12226 131 B3-U0-G2 LW SC 10457 144 B3-U0-G1 10724 148 B3-U0-G1 11148 154 B3-U0-G1 73AC9145126B2-U0-G2 9379 129 B2-U0-G2 9749 134 B2-U0-G2 VLW SC 8783 146 B3-U0-G1 9008 149 B3-U0-G1 9364 155 B3-U0-G1 60AC7681127B2-U0-G1 7878 131 B2-U0-G1 8189 136 B2-U0-G1 SLW SC 5585 146 B2-U0-G1 5728 150 B2-U0-G1 5954 156 B2-U0-G1 38AC4884128B1-U0-G1 5009 131 B1-U0-G1 5207 136 B1-U0-G1 ELECTRICAL DATA (AMPS) Lumen Package Wattage 120V 208V 240V 277V 347V 480V VHO 152 1.27 0.73 0.64 0.55 0.44 0.32 HO 124 1.03 0.6 0.52 0.45 0.36 0.26 SS 92 0.77 0.44 0.38 0.33 0.27 0.19 LW 72 0.6 0.35 0.3 0.26 0.21 0.15 VLW 60 0.5 0.29 0.25 0.22 0.17 0.13 SLW 38 0.32 0.18 0.16 0.14 0.11 0.08 *LEDs are frequently updated therefore values are nominal. *Electrical data at 25C (77F). Actual wattage may differ by +/-10%. FOOTNOTES: 1 - Lumen maintenance values at 25˚C are calculated per TM-21 based on LM-80 data and in-situ luminaire testing. 2 - In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on Accessory Ordering Information (Accessories are field installed) Description Order Number Description Order Number Retrofit Panels - EC / ECTA / SCF to CRUS, for 16” Deck Panel 525946 Retrofit RIC Cover Panel Blank (no holes)354702 Retrofit Panels - ECTA / SCF to CRUS, for 12” Deck Panel 530281 Kit - Hole Plugs and Silicone (enough for 25 retrofits)1 1320540 Retrofit 2x2 Cover Panel Blank (no holes) 357282 1 - Consists of (25) 7/8” hole plugs, (100) 5/16” hole plugs and (1) tube of RTV time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing (DUT) i.e. the packaged LED). 3 - In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times NA LM-80-08 total test duration (in hours) for the device under testing (DUT) i.e. the packaged LED). 3. Custom lumen and wattage packages available consult factory. Values are within industry standard toler- ances but not DLC listed. LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 3/4 Rev. 10/19/20 SPEC.1020.A.0420 Type: Scottsdale® Legacy LED Canopy Luminaire (CRUS) Back to Quick Links Luminaire photometry has been conducted by an accredited testing laboratory in accordance with IESNA LM-79-08. As specified by IESNA LM-79-08 the entire luminaire is tested as the source resulting in a luminaire efficiency of 100%. See http://www.lsi-industries.com/products/led-lighting-solutions.aspx for detailed photometric data. PHOTOMETRICS LUMINAIRE DATA Type 5 Distribution Description 5000 Kelvin, 80 CRI Delivered Lumens 13,980 Watts 93 Efficacy 150 IES Type Type VS - Very Short BUG Rating B3-U0-G1 LUMINAIRE DATA Type 3 Distribution Description 5000 Kelvin, 80 CRI Delivered Lumens 12,226 Watts 93 Efficacy 131 IES Type Type III, Very Short BUG Rating B3-U0-G2 Zonal Lumen Summary Zone Lumens %Luminaire Low (0-30°)3654.2 26% Medium (30-60°)7541.2 54% High (60-80°)2641.4 19% Very High (80-90°)143.2 1% Uplight (90-180°)0 0% Total Flux 13980 100% Zonal Lumen Summary Zone Lumens %Luminaire Low (0-30°)3240.3 27% Medium (30-60°)6245.5 51% High (60-80°)2594.6 21% Very High (80-90°)146.1 1% Uplight (90-180°)0 0% Total Flux 12227 100% CRUS-SC-SS-50 CRUS-SC-SS-50 ISO FOOTCANDLE ISO FOOTCANDLE POLAR CURVE POLAR CURVE .5 1 2 5 1125 2251 3376 4501 1 2 15’ Mounting Height/15’ Grid Spacing 5 FC 2 FC 1 FC .5 FC .5 1 2 5 1325 2649 3974 5298 1 2 15’ Mounting Height/15’ Grid Spacing 5 FC 2 FC 1 FC .5 FC LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsicorp.com (513) 372-3200 • ©2020 LSI Industries Inc. All Rights Reserved. Specifications subject to change without notice. Page 4/4 Rev. 10/19/20 SPEC.1020.A.0420 Type: Scottsdale® Legacy LED Canopy Luminaire (CRUS) PRODUCT DIMENSIONS Back to Quick Links 7 1/8”(181 mm) 11/16”(17 mm)15 11/16” (399 mm)15 11/16” (399 mm) 15 11/16”(399 mm)10 3/4”(273 mm)